New Laboratory System from SUEZ Water UK Cuts the Cost of Pure Water Production

15 Jun 2017
Lois Manton-O'Byrne
Executive Editor

SUEZ Water UK, the leading water purification and wastewater treatment company, has launched an innovative new laboratory system, designed to reduce operating costs for laboratory water purification systems. Developed as a standard benchtop unit, the new Select edi 60 combines double-pass reverse osmosis (RO) and electro-deionization (EDI) technologies in a single compact system. This approach eliminates the need for conditioning cartridges and carbon dioxide pre-treatment filters, dramatically reduces total dissolved solids (TDS) and offers significantly improved energy efficiency.

EDI systems are widely used in laboratories for a wide range of duties, producing water to Grade I, II and II qualities. Although an effective solution, EDI cells are particularly sensitive to the presence of calcium and magnesium ions in the source water. EDI cells can also be damaged by the presence of dissolved carbon dioxide, while high levels of TDS will lead to a rapid decline in deionization efficiency.

The solution employed in most laboratory EDI units is to install conditioning cartridges to reduce water hardness, pre-treatment filters to reduce dissolved carbon dioxide and single-pass RO membranes to protect each EDI cell still further. This arrangement, however, leads to high operating costs, which are often overlooked at the time of purchase. These can significantly increase total costs of ownership, especially in laboratories using high volumes of water or operating in hard water areas.

SUEZ Water UK has overcome these issues by, for the first time in a compact laboratory unit, combining double-pass RO and EDI technologies. This system operates efficiently with even the hardest of feed water sources, providing continuous and consistent volumes of water at the correct quality to the EDI cell and significantly reducing the need for consumables and maintenance.

This configuration also reduces TDS to extremely low levels. With a single pass RO there is typically a 96-98% reduction in TDS, while in a double pass system the remaining impurities are further reduced by 96-98%. This provides greater protection to the EDI cell, preventing scaling and helping to optimize its operating life, and results in higher overall quality of the purified output water.

Additionally, the use of the latest hollow fiber gas transfer membranes, allow dissolved carbon dioxide to be stripped efficiently from the water, as it passes from the water phase into the gaseous phase across the fibers. The process is highly effective and is driven by air provided by an on-board mini air pump.

The new Select edi 60 is easy to setup and use, with all controls being via a front panel mounted color LCD, making it ideal for applications such as buffering, stains, reagent make-up, glassware rinsing and media preparation. The unit has a standard 20-litre tank, with 50 and 100 liter tanks available as options. With a feed water pressure of 2 bar, the unit produces 6 liters/hour at 10°C, and 10 liters/hour at 25°C. A feed water boost pump is fitted as standard to guarantee production rate.

The unit measures just 440 x 560 x 750mm, and is available in bench top or wall-mounted versions. It has a shipping weight of 25kg, and a maximum working weight of 45kg.