AdvanceBio RP-mAb
Agilent TechnologiesAgilent AdvanceBio RP-mAb columns are designed to optimize the performance of intact and reduced mAb analysis when analyzing monoclonal antibodies for biopharma discovery, development, and QA/QC applications
Agilent AdvanceBio RP-mAb columns are designed to optimize the performance of intact and reduced mAb analysis when analyzing monoclonal antibodies for biopharma discovery, development, and QA/QC applications
PLRP-S for Biomolecules products are available in a range of pore sizes and particle sizes, all with identical chemistry and fundamental adsorptive characteristics. The particles are inherently hydrophobic so there is no bonded phase, alkyl ligand required for reversed-phase separations.
Agilent ZORBAX 300Å StableBond columns are an ideal choice for the reproducible separations of proteins and peptides.
Agilent AdvanceBio HIC columns deliver robust and reproducible high-resolution separations of native proteins at the intact level.
The Oligonucleotide Resolution standard contains 14, 17, 20, and 21 mer synthetic oligonucleotides and is designed to test N / N-1 resolution.
ZORBAX capillary (0.5 mm, 0.3 mm id) and nano (0.1 mm, 0.075 mm id) columns are available in a wide range of phases, pore sizes (80 Å and 300 Å), and dimensions.
ZORBAX 300Extend-C18 is a wide-pore HPLC column for high efficiency separations of peptides, polypeptides, and small proteins from pH 2-11.5.
PL-SAX strong anion-exchange materials are extremely hydrophilic and are designed for purification of biomolecules. The materials are totally polymeric and are chemically and thermally stable over a full range of HPLC conditions.
PL-SCX strong cation-exchange materials are extremely hydrophilic and are designed for purification of biomolecules. The materials are totally polymeric and are chemically and thermally stable over a full range of HPLC conditions.
The PLRP-S media, rigid poly(styrene/divinylbenzene) particles, are available in a range of pore sizes for small molecule, synthetic biomolecule and macromolecule purification.
The VariTide RPC columns and media are part of the VariPep Peptide Solution.
The 1220 Infinity II Analytical-Scale Purification System is an affordable, entry level, high-quality system based on proven technology. Four integrated, all-in-one configurations are available to get you on the fast track to efficiency and maximum return-on-investment.
The 1260 Infinity II Analytical-Scale LC Purification System is the most flexible and versatile solution for compound isolation within the InfinityLab LC purification portfolio. Ideal for purification of multi-milligram quantities of materials, the standard configuration handles flow rates between 0.1 and 10 mL/min with 2.1 and 10.0 mm id columns.
The 1290 Infinity II Analytical-Scale LC Purification System embodies the future of UHPLC compound isolation with the exceptional reliability and robustness you expect from the InfinityLab LC Series, plus breakthrough technologies to maximize the efficiency of your purification laboratory.
The 1260 Infinity II Manual Preparative LC System is an easy-to-use, entry-level solution for LC purification with upgrade possibilities to do routine purification of milligram up to gram scale quanities of materials. This binary gradient system delivers dynamic flow rates up to 50 mL/min at 420 bar, equipped with a manual injection valve. The system achieves outstanding performance and reliability day-in and day-out, and is t…
The 1260 Infinity II Preparative LC System is an easy-to-use workhorse for automated sample injection when gradient elution is required for sample purification. The binary gradient pump deliver flow rates up to 50 mL/min for purification up to 30.0 mm id columns. This system is tailor-made for routine, high-throughput, laboratory-scale purification when milligrams to grams of starting material are available.
The 1260 Infinity II Preparative LC/MSD System can be configured with UV and MS detectors as well as multiple fraction collectors to meet your purification needs. Automated sample injection increases daily sample throughput and mass-based fraction collection maximizes purity and minimizes re-analysis.
The 1290 Infinity II Preparative LC System is designed for the purification laboratory that needs increased daily throughput by offering automated sample injection and fraction collection, smooth control of LC valves, and flexible access to up to four analytical columns and six preparative columns.
The 1290 Infinity II Preparative LC/MSD System enables high-throughput purification, delivering high-quality compounds, for example, for biological screening, an important part of drug discovery.
The 1290 Infinity II Autoscale Preparative LC System is a scalable, workflow-based solution that facilitates automated scale-up from analytical method scouting to optimized purification.
The 1290 Infinity II Autoscale Preparative LC/MSD System is the ultimate workflow solution for direct scale-up from analytical scouting to gram-level purification of target compounds.
The 1260 Infinity Multidetector Bio-SEC System is completely metal-free and comprises light scattering and dynamic light scattering to allow determination of protein shape and size without the need for SEC column calibration. For research use only.
The 1290 Infinity II HDR-DAD Impurity Analyzer System has a 30 times higher dynamic range, 30 times higher UV sensitivity, plus UHPLC resolution and speed. Detect and quantify every component in your sample in a single run with superior area precision for low-level impurities.
The 1290 Infinity II High-Throughput System achieves highest analysis speeds utilizing the autosampler capacity of up to 16 cooled microplates and shortest cycle times without compromising on the robustness you need for an ultrahigh-performance liquid chromatography (UHPLC) system.
The 1290 Infinity II Method Transfer System features intelligent system emulation technology (ISET), which is specifically designed for both HPLC and UHPLC method transfer. The 1290 Infinity II Method Transfer System will deliver similar retention times and peak resolution for methods that were developed on legacy HPLCs or UHPLCs from other vendors. Replace many LCs with a single 1290 Infinity II Method Transfer System and si…