MagNA Lyser Rotor
RocheThe MagNA Lyser Rotor holds up to 16 sample tubes for tissue homogenization using the MagNA Lyser Instrument.
The MagNA Lyser Rotor holds up to 16 sample tubes for tissue homogenization using the MagNA Lyser Instrument.
Application The MagNA Lyser Green Beads (tubes prefilled with ceramic beads) are specially designed for use in the MagNA Lyser Instrument to achieve optimal homogenization of various sample materials (e.g., tissue, plant tissue, cells). The ceramic beads can be used with the optimized lysis buffers of the MagNA Pure LC reagent kits for nucleic-acid extraction with the MagNA Pure LC Instrument. Benefits The combination of the…
For use with:Cat. No. 03 172 627 001 MagNA Pure LC mRNA Isolation Kit II (Tissue) orCat. No. 03 330 591 001 MagNA Pure LC RNA Isolation Kit III (Tissue) For general laboratory use. The MagNA Pure LC RNA Isolation Tissue Lysis Buffer – Refill is designed for lysis and homogenization of fresh frozen tissue samples using a tissue homogenizer (see the MagNA Lyser Instrument) stabilization of total RNA and mRNA within samp…
Kit for determining the nucleotide sequence of an immobilized and clonally amplified DNA library prepared using the appropriate GS FLX Titanium series kits. The GS FLX Titanium PicoTiterPlate Kit 70x75 contains accessories sufficient for one sequencing run on a Genome Sequencer FLX Instrument. The kit is designed for use in combination with the GS FLX Titanium Sequencing Kit XLR70.Contents 70x75 GS FLX Titanium PTP Device 70x…
The GS FLX Titanium Control Bead Kit can be used as a standard sequencing control on the Genome Sequencer FLX Instrument. During a test sequencing Run, only Control Beads are sequenced. The Control Beads contain known DNA sequences that should yield sequencing results within expected parameters if the instrument is performing to specifications. The GS FLX Titanium Control Bead Kit is used in combination with a GS FLX Titanium…
For use with the GS FLX Titanium PicoTiterPlate Kit 70x75 and the Genome Sequencer FLX Instrument. The GS FLX Titanium Sequencing Kit XLR70, combined with the GS FLX Titanium PicoTiterPlate Kit 70x75, contains all reagents and other components required for one sequencing run on a Genome Sequencer FLX Instrument. The kit is designed for use with the GS FLX Titanium PicoTiterPlate Kit 70x75 and the Genome Sequencer FLX Instrume…
The GS Junior Titanium Sequencing Kit, combined with the GS Junior Titanium PicoTiterPlate Kit, provides reagents and other consumables required for determining the nucleotide sequence of an immobilized and clonally amplified DNA library, prepared using the appropriate GS Junior Titanium kits. After amplification, the DNA-carrying beads and sequencing reagents are deposited into the wells of the GS Junior PicoTiterPlate (PTP)…
The GS Junior Titanium PicoTiterPlate Kit, combined with the GS Junior Titanium Sequencing Kit, provides the devices and reagents required for determining the nucleotide sequence of an immobilized and clonally amplified DNA library. The DNA-carrying beads and sequencing reagents are deposited in layers into the wells of a PicoTiterPlate (PTP) device, such that each well contains no more than a single DNA bead. The loaded PTP d…
The GS Junior Titanium Control Bead Kit can be used as a standard sequencing control on the GS Junior Instrument. During a test sequencing Run, only Control Beads are sequenced. The Control Beads contain known DNA sequences that should yield sequencing results within expected parameters if the instrument is performing to specifications. The GS Junior Titanium Control Bead Kit is used in combination with a GS Junior Titanium Se…
The GS FLX Titanium emPCR Breaking Kit LV 12pc is used to break the emulsions and collect the beads from a single cup or up to a full day's worth of Large Volume Emulsion (LVE) Cups, providing they contain the same library. The kit contains components for 12 LV emulsion-breaking setups. Contents 12 pieces, each with one 8-channel transfer pipette, two 50 ml tube caps with tubing fittings, and tubing (approximately 1 meter in l…
The GS FLX Titanium emPCR Kits (Lib-A) contain all reagents and other components required for two large-volume (LV), medium-volume (MV) or small-volume (SV) emulsion-based clonal amplifications of DNA libraries prepared using the Genome Sequencer System library preparation procedure (Amplicons), for subsequent sequencing on a Genome Sequencer FLX Instrument using the appropriate GS FLX Titanium series Sequencing and PicoTiterP…
Kits for large-volume (LV), medium-volume (MV) and small-volume (SV) emulsion-based clonal amplification of a DNA library prepared using the appropriate GS FLX Titanium series library preparation procedure. The GS FLX Titanium emPCR Kits (Lib-L) contain all reagents and other components required for two emulsion-based clonal amplification reactions (which can be pooled, if applicable). Contents The GS FLX Titanium emPCR Kits…
Monitor the sequence of the SARS-CoV-2 virus and the emergence of new variants
The VENTANA MMR RxDx Panel is the first and only immunohistochemistry-based assay approved to identify endometrial carcinoma patients eligible for treatment with JEMPERLI (dostarlimab).
First IHC companion diagnostic for determining folate receptor alpha (FOLR1) protein expression in EOC patients who may benefit from ELAHERE™ (mirvetuximab soravtansine)
SeqCap EZ Library is a solution-based capture method that enables enrichment of the whole exome or customer regions of interest in a single test tube. Built upon an optimized design algorithm, SeqCap EZ Library sets a new standard for a simple single-step enrichment method.
Source: UCSC Build: HG18, NCBI 36 Probe Length: 60mer Median Probe Spacing: 1169bp Platform: HD2 Probes per Array: 2,100,000 Feature Size: 13μm x 13μm Array Dimensions: 62mm x 14mm Overall Slide Dimensions: 1" x 3" (25 x 75mm) Recommended Storage: Store arrays desiccated at room temperature.
Roche NimbleGen provides a unique combination of high-density arrays, long-oligo probes, and flexible design capability that together provide superior results for advanced gene expression analysis. NimbleGen microarrays enable accurate, sensitive, and specific interrogation of genome-wide expression for any sequenced and annotated genome. Researchers also can tile through a genome at any desired spacing to discover genome-wide…