Products & Reviews

25

Product Filter

Materials
Browse by Techniques
VICI AG International

Ratings

Search

Selected Filters:

miniPDD Helium Ionization Detector

VICI AG International

The newest member of the PDD family is also the smallest and thriftiest. The miniPDD uses about one fifth (20%) the amount of helium as the D-3 and D-4 versions, giving up only a bit of sensitivity and dynamic range in return. It is approximately one half the size of the D-4, but has nearly the same sensitivity — about 100 ppb for fixed gases. With its reduced size, weight, and helium consumption, it is particularly well sui…

0.0/5.0
|0 Reviews

Pulsed discharge detectors Model D-2

VICI AG International

VICI introduces the GC detector where the PDD (pulsed discharge detector) utilizes a stable, low-powered, pulsed DC discharge in helium as the ionization source. The D-2 is a dual mode, universal detector system which can be retrofitted to your older GC. The D-2-I is a helium photoionization detector, optimized for trace level work with packed columns. The stand-alone systems include detector, controller, electrometer, helium…

0.0/5.0
|0 Reviews

Pulsed discharge detectors Model D-3

VICI AG International

Pulsed discharge detector Model D-3 is designed for plug-and-play installation on Agilent GC's, with models available for the 6890 and 7890. The D-3 is optimized for trace level work in the helium photoionization mode, and utilizes the electronics and power supply of the host GC. Model D-5 is optimized for electron capture detection. Available for 110 VAC and 230 VAC.

0.0/5.0
|0 Reviews

Pulsed discharge detectors Model D-5

VICI AG International

Model D-5 is a pulse discharge GC detector designed for plug-and-play installation on the Agilent 6890. The D-5 is optimized for trace level work in the electron capture mode, and utilizes the electronics and power supply of the host 6890. Model D-3 is optimized for helium photoionization detection. Available for 110 VAC and 230 VAC.

0.0/5.0
|0 Reviews

Pulsed discharge detectors; Model D-4

VICI AG International

Model D-4 a GC Detector available in versions for easy installation on most of the GC's in current use, including the Varian 3800, Shimadzu 14 and 17, ThermoFinnigan Trace, Mega, and Top, and Hewlett Packard 5890. The D-4 is single mode, optimized for trace level work in the helium photoionization mode. Available for 110 VAC and 230 VAC.

0.0/5.0
|0 Reviews

Pulsed discharge detectors Model D-6

VICI AG International

Model D-6 is a single mode GC detector, optimized for trace level work in the electron capture mode. IT is available in versions for easy installation on most of the GC's in current use, including the Varian 3800, Shimadzu 17, ThermoFinnigan Trace, Mega, and Top, and Hewlett Packard 5890.  Available for 110 VAC and 230 VAC.

0.0/5.0
|0 Reviews

Reduced breakdown injection port liners

VICI AG International

Reduced breakdown liners Our improved injection port liner reduces breakdown of endrin and DDT during injections while increasing the interval between liner changes. The problem DDT and Endrin are easily degraded in the injection port; with non-deactivated liners and those filled with non-deactivated glass wool, Endrin breakdown can be as high as 98%. EPA method 8081A states "If degradation of either DDT or Endrin exceeds 15%,…

0.0/5.0
|0 Reviews

ValcoBond® columns

VICI AG International

VICI AG uses proprietary liquid phase processing to produce low bleed characteristics while maintaining identical retention characteristics to the phases you are used to. These processes combined with proprietary coating, curing, bonding, and crosslinking produce MS-certified bleed characteristics equal to the best. Improved upper temperature limits enhance column "bake out", reducing sample carryover and cycle times. ValcoBon…

0.0/5.0
|0 Reviews

ValcoPLOT® columns

VICI AG International

Now you can reduce run time, faster than micropacked, by replacing your packed columns with ValcoPLOT HayeSep capillary PLOT columns, with phases available only from VICI. Our proprietary phase processing produces the first capillary PLOT columns with characteristics identical to HayeSep packed columns. The ValcoPLOT line also includes Molesieve and Alumina PLOT columns.  Visit VICI AG website to veiw now.

0.0/5.0
|0 Reviews

Dynacal® permeation tubes

VICI AG International

Permeation tubes are small, inert capsules containing a pure chemical compound in a two phase equilibrium between its gas phase and its liquid or solid phase.  They are used to generate a stable concentration of a specific trace chemical. At a constant temperature, the device emits the compound through its permeable portion at a constant rate. They are typically inserted into a carrier flow to generate test atmospheres for c…

0.0/5.0
|0 Reviews

G-Cal permeation tubes

VICI AG International

Patented G-Cal permeation tubes offer a proven and repeatable means of generating a desired gas or vapor concentrations. The permeant gas escapes through the proprietary membrane system and mixes with a carrier gas (nitrogen is the most common) at a controlled flow rate to obtain a known mixture in ppm or ppb. Applications include calibration of gas monitoring systems and chromatographs, accuracy check of gas detectors, and ge…

0.0/5.0
|0 Reviews

Contaminant traps

VICI AG International

Ultra-high capacity for the contaminant of interest; either Moisture, Hydrocarbons, Oxygen, Sulfur and Mercury. For applications with a single contaminant of interest, high capacity contaminant specific traps are your best option, since they generally have four times as much capacity for the specific contaminant as a purifier. This translates to a capacity that exceeds twelve standard type "A" tanks of gas or the equivalent of…

0.0/5.0
|0 Reviews

Helium and nitrogen purifiers

VICI AG International

VICI AG heated helium purifier provides point-of-use purification of helium or other noble gases, such as Ar, Ne, Kr, and Xe, to sub-ppm levels of reactive gaseous impurities, removing even nitrogen and methane. The nitrogen purifier is similar, purifying nitrogen to sub-ppm levels of gaseous impurities. The miniature version of each purifier is designed to be installed in a GC’s flow path immediately upstream of the injector.…

0.0/5.0
|0 Reviews

Gas Purifiers

VICI AG International

Gas purifiers for specific gases designed to go in-line with the carrier or detector gas supply, these gas purifier modules dramatically reduce contaminant PPM levels in helium, hydrogen, nitrogen, or air. They decrease baseline noise and increase GC/MS sensitivity and replace three traps with one gas purifier.This line includes original equipment gas purifiers for the Agilent Mass Spec and LC Mass Spec. Additional specialized…

0.0/5.0
|0 Reviews

Hollow plunger syringes

VICI AG International

Hollow, flow-through plunger with integrated 3-way valve designed for liquid and gases, with a push button on/off valve at the front end. The new Precision Sampling hollow plunger syringe with two integrated valves opens a whole new world of application possibilities: Dispense a viscous sample more easily by introducing it into the rear of the syringe instead of drawing it up through the needle. Eliminate sample-to-sample cros…

0.0/5.0
|0 Reviews

Dual Layer PEEK tubing

VICI AG International

The Dual Layer PEEK tubing eliminates any concern that a critical sample stream could be contaminated by pigments used to color code the tubing.  The pigmented layer surrounds a separate but integrally-bonded inner layer of natural PEEK. The 1/16" OD tubing is available in standard sizes, or in OEM quantities with any ID you specify, from .002" to .030". The ID tolerance of ±.001" is equivalent to or better than that of tubing…

0.0/5.0
|0 Reviews