SunFire™ 2.5 μm Columns
WatersAchieve faster run times and improved sensitivity with a smaller particle size
Achieve faster run times and improved sensitivity with a smaller particle size
ACQUITY UPLC® BEH Phenyl columns utilize a trifunctional C6 alkyl tether between the phenyl ring and the silyl functionality. This ligand, combined with the same proprietary endcapping processes as the ACQUITY UPLC™ BEH C18 and C8 columns, provides ultra-low column bleed, long column lifetimes and excellent peak shape. This unique combination of ligand and endcap on the 1.7 μm BEH particle creates a new dimension in selectivi…
Waters offers a broad range of vials, each one is held to tight dimensional tolerances and the certified products have cleanliness measured by LC and MS.LC/GC Certified vials are tested by LC/UV for residues of chemicals used in processing and packaging vials. The septa are tested by headspace GC to ensure low levels of low molecular weight polymer. These vials are suited for analyte concentration in the µg/mL concentration; t…
The Waters IdentityE High Definition Proteomics system defines the new standard for rigorous protein identification. The IdentityE High Definition Proteomics System is an UltraPerformance LC® (UPLC)/High-Bandwidth Mass Spectrometry (MS E) system solution suitable for confident protein identification designed to meet stringent requirements as outlined by leading scientific journals.The new Waters IdentityE High Definition Pro…
The ACQUITY UPLC® Fluorescence (FLR) Detector brings unrivaled sensitivity and selectivity to UPLC®. The detector’s innovative flow-cell design, low-noise electronics and support for high-speed data rates are perfectly suited to the efficient separations of the ACQUITY UPLC's advanced fluidics technology. Target applications include PAHs, environmental contaminants, vitamins, aflatoxins and pharmaceuticals. Ultra Performance i…
SymmetryShield™ Columns feature Waters' patented embedded polar group technology that shields the silica's residual silanols from highly basic analytes at improves overall peak shape. Additionally, by placing the embedded polar group close to the silica surface, the activity of the surface silanols is further reduced. This imparts selectivity and retention that is different compared to the Symmetry C18 ligand. Embedded polar…
Polynuclear Aromatic Hydorcarbons (PAHs) are among the most frequently monitored environmental contaminants. Waters PAH columns are optimized for the HPLC analysis of PAHs. These columns achieve baseline resolution and excellent peak symmetry for 16 different target analytes in less than 25 minutes, while employing a simple water/acetonitrile binary gradient method. The resolving power of the PAH columns provides superior pe…
The popular Bondapak® C18 chemistry and Porasil® silica packing material are available in three different particle sizes, 10, 15-20, 37-55 micron, providing easy transfer of chromatography methodology from one particle size to another. You can utilize your existing 10 micron Bondapak or Porasil chromatography as a starting point for scale-up or, if you are developing a new purification protocol, investigate which preparative…
These columns provide accurate and precise molecular weight calculations in under 7 minutes! - Fast, accurate and precise molecular weight determinations - Increase sample throughput - Greatly decrease solvent consumption and disposal
The Envirogel high-efficiency GPC cleanup columns are specifically designed to remove low volatility, high molecular weight interferences, such as lipids and natural resins, from environmental samples as specified in EPA Method 3640A. In the past, the cleanup procedure for environmental samples was performed on low-efficiency GPC columns based on packing particle diameters of 37-75 micron (200 to 400 mesh) Bio-Beads S-X resins…
For applications where the sample is neither volume or concentration limited, Waters offers 1 and 2mm Internal Diameter columns of various lengths for use on traditional HPLC MS inlets.As with Waters array of NanoEase™ columns, the same Waters reversed-phase packings are also available in these two column internal diameter offerings. Chemistry choices include: XBridge® Columns, CORTECS® Columns, XSelect Columns, Atlantis® Pola…
MassPREP™ On-Line Desalting Cartridges are an effective tool for the successful desalting of acidic, basic, and large globular proteins. The overall MassPREP™ desalting strategy provides an easy, fast (< 3 minutes), and reproducible approach for the effective desalting of proteins stored in physiological salt buffers prior to high resolution ESI-MS structural analysis.
Waters offers PoraPak™ Rxn, a family of polymer-based chromatography products for superior cleanup of synthetic reactions. PoraPak Rxn products are available in two chemistries: PoraPak Rxn CX, a strong cation-exchange sorbent and PoraPak Rxn RP, a reversed-phase sorbent.PoraPak Rxn sorbents are based on copolymers that exhibit the following properties:Hard material that does not develop increasing back pressure with flowLitt…
Developed for your most demanding LC/MS/MS quantitative applications, the Quattro Premier™ XE tandem quadrupole mass spectrometer features the highest levels of sensitivity, selectivity, robustness, speed and accuracy. To maximize the analytical advantages of your ACQUITY UPLC® System, the Quattro Premier XE operates at the highest data acquisition rates. Together, the ACQUITY UPLC® System and the Quattro Premier XE give you i…
DisQuE Dispersive Sample Preparation is a well proven, high throughput sample preparation method for a wide array of pesticides in produce. The kit contains conveniently packaged vials with pre-measured sorbents and buffers used to provide extraction and clean-up for up to 100 samples. Each 50 mL DisQuE Extraction tube contains 6 grams of magnesium sulphate and 1.5 grams of sodium acetate. Each 2 mL DisQuE Clean-Up tube cont…
Thar Instruments, makers of the TharSFC line of green chromatography Method Station system, is what most people describe as a methods development system for screening multiple compounds with multiple columns and multiple mobile phase compositions. The Analytical Supercritical Fluid Chromatography Method Station II features a smaller footprint despite a new larger Analytical–2–Prep Column Oven and expanded capacity high–speed…
Introducing Viridis SFC columns for purification incorporating our patented Prep OBD column technology. Combining state-of-the-art media manufacturing with the industry leading column technology, Viridis Supercritical Fluid Chromatography (SFC) columns bring a new level of reproducibility to the world of laboratory scale purification. Viridis SFC columns are available for analytical and preparative chromatography as: Virid…
The 515 HPLC pump is a programmable, free-standing HPLC pump available in isocratic, gradient, and semi-preparative configurations: • Precise stepper motor control (48 steps/µL resolution) of dual reciprocating pistons • Non-circular drive gears provide smooth, uniform eluent delivery • User-programmable flow rate calibration and compressibility compensation factors ensure straightforward pump operation qualification • Tests t…
The Waters 3100 Mass Detector is a compact, single-quadrupole atmospheric pressure ionization (API) mass detector that provides selectivity, sensitivity, and throughput with faster scan speeds. Designed specifically for chromatographers performing LC/MS analysis, it offers a simple yet powerful solution for multi-tasking, fast-paced laboratory environments – with robust and reliable performance, and walk-up operation for any e…
The Waters OpenLynx™ Open Access Application Manager provides walk-up access for LC/UV, LC/MS, LC/MS/MS, and GC/MS operation in laboratories whose chemists have varying levels of instrumental analysis experience. OpenLynx also provides customizable batch processing to support the large amounts of data generated by high-throughput analyses. It comes standard with MassLynx™ Software. Features of Waters OpenLynx: Easy to Learn T…
Introducing the ACQUITY UPSFC System Built on the Waters proven UPLC platform that revolutionized the industry by introducing sub-2-µm particle chemistry, this game-changing UPSFC solution enables you to confidently conduct normal-phase chromatographic separations— including chiral and achiral applications. Using carbon dioxide rather than toxic solvents as the main mobile phase, you can now minimize harmful waste while gainin…