Hamilton RCX-10 And RCX-30 Columns

Hamilton Company

Hamilton RCX-10 And RCX-30 Columns for the Anion Exchange Separation of CarbohydratesHamilton RCX-10 carbohydrate analysis columns are designed for the isocratic and gradient separation of carbohydrates. Samples containing two or three carbohydrates, for example Ice Cream can be quickly separated isocratically while more complex samples like Corn Syrup, require gradient elution to fully resolve all the oligomers (DP1 to DP7).…

0.0/5.0
|0 Reviews

HC-75

Hamilton Company

Separate Mono and Disaccharides or Carbohydrate Oligomers from DP1 to DP8.Hamilton HC-75 columns separate carbohydrates by ligand exchange and size exclusion mechanisms.HC-75 is a more highly crosslinked gel (7.5%) that utilizes ligand exchange to separate carbohydrates. Calcium, Hydrogen and Lead are available as counter ions. The calcium form column is more commonly used because of its broader applicability.For application e…

0.0/5.0
|0 Reviews




Sucralose

CHEMOS GmbH

Sucralose Synonyms: 1,6-Dichloro-1,6-dideoxy-beta-D-fructofuranosyl-4-chloro-4-deoxy-alpha-D-galacotopyranoside CAS No.: 56038-13-2

0.0/5.0
|0 Reviews

Hysphere Range of SPE Cartridges

Spark System Solutions B.V.

The HySphere™ cartridge range has been specially developed for the Symbiosis / Prospekt on-line SPE system. The sorbents are exclusively developed by Spark to ensure optimal efficiency and reproducability for a wide range of compounds. The most important feature is the size of the sorbent particles, which is (for most sorbents) < 10 µm as compared to 40 µm in traditional SPE tubes. The elution volume of the 8 µm cartridge is m…

0.0/5.0
|0 Reviews

Direct Sample Probe

Thermo Fisher Scientific

The Direct Sample Probe system for the Finnigan TRACE DSQTM, Finnigan FOCUS DSQ, and Finnigan PolarisQ is ideal for qualitative or semi-quantitative analysis of materials that are difficult, if not impossible to elute chromatographically.Product detail:The Direct Sample Probe system for the Finnigan TRACE DSQTM, Finnigan FOCUS DSQ, and Finnigan PolarisQ is ideal for the quick screening of samples or for any application which d…

0.0/5.0
|0 Reviews

Finnigan MAT95XP

Thermo Fisher Scientific

The MAT 95 XP is a highly flexible GC-MS system fully automated regardless of injector type and offers multicolumn operation as a standard feature.  Autotuning  assures optimized instrument performance with minimal user interaction at any resolution setting – fast, automated and reproducible, and only ONE calibration table making for simpler operation. Product detail: High mass resolution Accurate mass High sensitiv…

0.0/5.0
|0 Reviews

MAT 252

Thermo Fisher Scientific

The Thermo Finnigan MAT252 stable isotope mass spectrometer system is the world standard for the determination of H/D, 13C/12C, 15N/14N, 18O/16O, 34S/32S (from SO2 to SF6) as well as Kr and Xe isotope ratios. The design philosophy of the MAT 252 was "e;no compromises"e;, with the aim of delivering ultimate performance.The MAT252 is unique in its capability to achieve the highest precision from extremely small amounts of sample…

0.0/5.0
|0 Reviews

Alkaline Phosphatase

The Alkaline Phosphatase is purified from calf intestine by a method developed in our laboratories, involving affinity chromatography. This enzyme is widely used as a marker enzyme in applications such as: • ELISA Immunoblotting Immunohistochemistry Molecular Biology Activity: >630 U*/mg enzyme protein (25°C, 4-nitrophenyl phosphate, glycine as buffer) • Unit definition: That amount of enzyme causing the hydrolysis of one mi…

0.0/5.0
|0 Reviews

SamplePLUS

The SamplePLUS is a 100% synthetic sample buffer for dilution of human or veterinary serum or plasma samples.The buffer efficiently minimizes cross-reactions, background and unspecific binding without inhibiting the specific binding.

0.0/5.0
|0 Reviews

Sample Tracer

The Sample Tracer is a 100% synthetic sample buffer for dilution of human or veterinary serum or plasma samples. The buffer efficiently minimizes cross-reactions, background and unspecific binding without inhibiting the specific binding. The Sample Tracer™ appears red, and when serum or plasma is added the Sample Tracer™ change colour to yellow. The buffer can detect serum or plasma in dilutions up to 1:100. If the advantage…

0.0/5.0
|0 Reviews

FAST RED Tablets

Fast Red is used as a chromogen substrate in immunoblotting and immunohistochemistry using alkaline phosphatase antibody conjugates. Each tablet contains 0.5 mg naphthol phosphate, 2 mg FAST RED chromogen and 0.4 mg levamisole, an inhibitor of endogenous enzyme activity. Stability life time is 18 months at 4°C.

0.0/5.0
|0 Reviews

Finnigan DELTAplus XP

Thermo Fisher Scientific

The Finnigan DELTAplusXP is the univeral routine and research stable isotope ratio mass spectrometer for all applications using dual-inlet and continuous-flow techniques. Its extended image plane supports continuous flow D/H measurements as well as the determination of atmospheric gases. The amplifier dynamic range is 50 V. Product detail: The DELTAplusXP combines the extended ion optics of the DELTAplusXL with completely…

0.0/5.0
|0 Reviews

Biomass Deconvolution - Biological Analyses

Thermo Fisher Scientific

Biomass Deconvolution is an Xcalibur layered application that enables users to perform commonly used standard tasks in the application of mass spectrometry to samples and analyses that contain biological molecules such as proteins, peptides, and oligonucleotides . The BioBrowser™ window contains commands and features specific for analyzing biological molecules including Biomass Calculation and Biomass Deconvolution.BIOMASS Cal…

0.0/5.0
|0 Reviews

Xaminer

Thermo Fisher Scientific

Xaminer, a software product, provides rapid, automated matching of complex GC/MS data files, can automatically perform flammable liquid residue analysis of samples from arson cases at least 20 times faster than had previously been the case, and produces consistent, unbiased quantitative results every time.  Product detail: Xaminer, the new chromatographic matching and instrument control software product, provides rapid, a…

0.0/5.0
|0 Reviews

Agilent Pursuit XRs Diphenyl HPLC Columns

Agilent Technologies

100Å pore size, high ligand density;  available in 1.0, 2.0,  3.0, 4.6 and 10 mm ids;  30 - 250 mm lengths. Pursuit columns are ideal for pharmaceutical applications using LC/MS, from analyzing lead compounds and biological samples in drug discovery, to implementing dependable analysis of raw materials and approved drugs in the QC process.  Build on the large 200A pore size silica, high liquid density delivers up to 40% faster…

0.0/5.0
|0 Reviews


Bond Elut Plexa

Agilent Technologies

Advanced Polymer Technology for Simplified SPE   Bond Elut Plexa offers simple, easy-to-use methods with general purpose extraction mechanisms to simplify SPE. In addition, Plexa provides performance enhancements due to a unique polymeric architecture with a non-retentive, hydroxylated, amide-free surface and a non-polar PS/DVB core for retaining small molecules. Binding of proteins and lipids on the polymer surface is minimiz…

0.0/5.0
|0 Reviews

Bond Elut Plexa PCX

Agilent Technologies

Polymeric Cation Exchange for Simplified SPE   Bond Elut Plexa PCX is a further milestone in the development of simple and robust SP methods. Plexa PCX uses a polymeric cation exchange resin that combines the outstanding properties of Bond Elut Plexa - superior flow characteristics and improved analytical performance - with strong cation exchange functionalities. This mixed-mode SPE sorbent removed neutral and acidic interfere…

0.0/5.0
|0 Reviews

Astec CHIROBIOTIC™ V2 Chiral HPLC Column

Sigma-Aldrich Supelco

The polar organic and the polar ionic modes have become increasingly popular largely because of their ideal compatibility with MS detection and preparative LC. Two years of extensive research at Astec in understanding these mechanisms has resulted in new possibilities for extending their effectiveness even further. Important changes in linkage chemistries and the silica and the silica have now led to the new CHIROBIOTIC V2 and…

0.0/5.0
|0 Reviews

SupelMIP™ SPE - Beta-agonists

Sigma-Aldrich Supelco

bed wt. 25 mg, volume 10 mL , (LRC), pk of 50 Application A class selective MIP phase for the multi-residue extraction of beta-agonists in urine, tissues, and other biological fluids. SupelMIP - Beta-agonists was developed for the selective extaction of a broad range o beta-agonists such as brombuterol, clenbuterol, formoterol, isoxuprine, mapenterol, ractopamine, ritrodine, salbutamol, salmeterol, terbutaline, tulobuterol, zi…

0.0/5.0
|0 Reviews

Agilent 1290 Infinity II Evaporative Light Scattering Detector

Agilent Technologies

The 1290 Infinity II Evaporative Light Scattering Detector (ELSD) is ideal for reproducible, sensitve detection of both volatile and nonvolatile compounds that cannot be detected by UV. A unique peltier cooled evaporator coupled with an original gas flow design allow subambient operation down to 10 °C. This delivers maximum sensitivity for compounds with significant volatility below 30 °C.

0.0/5.0
|0 Reviews

Midi HPCCC range

Dynamic Extractions

The DE Midi range of High Performance CCC (HPCCC) equipment is based on traditional liquid/liquid partitioning and extends the purification options available to chemists, primarily in Development, who are looking purify samples from 5 grams to 1,000 grams of material. The equipment is easily connected and interfaced into existing LC equipment and provides options when existing solid phase technology cannot obtain the resolutio…

0.0/5.0
|0 Reviews