Corning® 33 mm Polyethylene Filling Cap with a Male MPC Polycarbonate with a 1/4 (6.4 mm) ID Coupling and a Female MPC Polycarbonate End Cap
Corning Life Sciences33mm polyethylene threaded cap Female MPC End Cap with a 1/4
Products, services, reviews and techniques used in the preliminary investigations of the disease; the cell biology, genetics and protein pathways using tissue culture, cloning and imaging.
33mm polyethylene threaded cap Female MPC End Cap with a 1/4
9.5cm2 growth area per wellFlat bottomsNonreversible lids with condensation rings to reduce contaminationIndividual alphanumerical codes for well identificationUniform footprint for ease in stackingCorning® CellBIND® surface treated for optimal cell attachmentSterilized by gamma irradiationCertified nonpyrogenic
3.8cm2 growth area per well Flat bottoms Nonreversible lids with condensation rings to reduce contamination Individual alphanumerical codes for well identification Uniform footprint for ease in stacking Corning® CellBIND® surface treated for optimal cell attachment Sterilized by gamma irradiation Certified nonpyrogenic
1.9cm2 growth area per well Flat bottoms Nonreversible lids with condensation rings to reduce contamination Individual alphanumerical codes for well identification Uniform footprint for ease in stacking Corning® CellBIND® surface treated for optimal cell attachment Sterilized by gamma irradiation Nonpyrogenic
0.95cm2 growth area per wellFlat bottomsNonreversible lids with condensation rings to reduce contaminationIndividual alphanumerical codes for well identificationUniform footprint for ease in stackingCorning® CellBIND® surface treated for optimal cell attachmentSterilized by gamma irradiationCertified nonpyrogenic
33mm polyethylene threaded cap Female MPC End Cap with a 3/8"" (9.5mm) ID Male MPC Coupling Sterilized by gamma irradiation
Flat bottoms with 360 µL total volume Recommended working volumes of 75 to 200 µL Corning® CellBIND® surface treated for optimal cell attachment Nonreversible lids with condensation rings to reduce contamination Sterilized by gamma radiation and nonpyrogenic Individual alphanumeric codes for well identification
Ideal for high throughput applications requiring added volume Improved sample recovery through the specially designed wells that feature a square geometry that tapers to a V-bottom point Solvent resistant polypropylene provides compatibility with many common organic solvents (e.g. DMSO, ethanol, methanol) Certified DNase- and RNase-free
450 µL working volume in standard height format that fully conforms to ANSI/SBS standards Reduced space requirements are achieved while maintaining full instrument compatibility Solvent resistant polypropylene provides compatibility with many common organic solvents (e.g. DMSO, ethanol, methanol) DNase- and RNase-free
450 µL working volume in standard height format that fully conforms to ANSI/SBS standards Reduced space requirements are achieved while maintaining full instrument compatibility Chemical Resistant Sealing Mats Certified DNase- and RNase-free
Provides for adequate gas exchange while maintaining a sterile barrier Fits all 96 and 384 well microplates and polypropylene blocks Certified DNase- and RNase-free
Ideal for high throughput applications requiring added volume Improved sample recovery through the specially designed wells that feature a square geometry that tapers to a V-bottom point Solvent resistant polypropylene provides compatibility with many common organic solvents (e.g. DMSO, ethanol, methanol) Certified DNase- and RNase-free
Feature uniform skirt heights for greater robotic gripping surface Solvent resistant polypropylene provides compatibility with many common organic solvents (e.g., DMSO, ethanol, methanol) Total volume is 360 µL; recommended working well volume is 75 to 200 µL Without lids; lids, sealing mats and tapes supplied separately
Feature uniform skirt heights for greater robotic gripping surface Solvent resistant polypropylene provides compatibility with many common organic solvents (e.g., DMSO, ethanol, methanol) Total volume is 360 µL; recommended working well volume is 75 to 200 µL Without lids; lids, sealing mats and tapes supplied separately
A modified Transwell permeable support containing a 12mm diameter 0.4 µm pore polycarbonate membrane supported by a detachable ring Once cells are grown to confluence on the Snapwell insert, the ring can be placed in a vertical or horizontal diffusion chamber. [Diffusion Chambers are available through Harvard Apparatus (www.harvardapparatus.com)] Packaged in 6 well plates
These 15mm diameter Netwell inserts have 74µm polyester mesh bottoms attached to polystyrene rings or housing They are used as tissue carriers, supports and strainers for culture of small organs, tissue slices or explants at the air-media interface Handy carriers are available for immunocytochemical staining of tissue slices (sold separately) Provides coarse filtration of tissue homogenates, cell suspensions and microcarr…
These 15mm diameter Netwell inserts have 440µm polyester mesh bottoms attached to polystyrene rings or housing They are used as tissue carriers, supports and strainers for culture of small organs, tissue slices or explants at the air-media interface Handy carriers are available for immunocytochemical staining of tissue slices (sold separately) Provides coarse filtration of tissue homogenates, cell suspensions and microcar…
These 24mm diameter Netwell inserts have 74µm polyester mesh bottoms attached to polystyrene to rings or housing They are used as tissue carriers, supports and strainers for culture of small organs, tissue slices or explants at the air-media interface Handy carriers are available for immunocytochemical staining of tissue slices (sold separately) Provides coarse filtration of tissue homogenates, cell suspensions and microc…
These 24mm diameter Netwell inserts have 440µm polyester mesh bottoms attached to polystyrene to rings or housing They are used as tissue carriers, supports and strainers for culture of small organs, tissue slices or explants at the air-media interface Handy carriers are available for immunocytochemical staining of tissue slices (sold separately) Provides coarse filtration of tissue homogenates, cell suspensions and micro…
Corning® FiltrEX™ 96-well White Filter Plates with 0.2 µm PVDF Membrane, Nonsterile
The Corning ® FiltrEX™ 96 well white filter plate with 0.2 µm hydrophilic PVDF membrane was designed with your application needs in mind. Specific design features include: Meets the ANSI/SBS1-2004 through ANSI/SBS 4-2004 standard dimensions to ensure automation compatibility Rigid sidewalls make the plate ideal for automation handling Wide skirt easily accommodates bar codes Individual filter discs are sealed in the wells…
The Corning® volume adapter applicator easily assemblies the filter plate to the adapter and ensures a perfect, leak-free fit.
The Corning ® FiltrEX™ 96 well white filter plate with 0.25mm (thickness) glass fiber filter was designed with your application needs in mind. Specific design features include: Meets the ANSI/SBS1-2004 through ANSI/SBS 4-2004 standard dimensions to ensure automation compatibility Rigid sidewalls make the plate ideal for automation handling Wide skirt easily accommodates bar codes Individual filter discs are sealed in the w…
The Corning ® FiltrEX™ 96 well white filter plate with 0.66mm (thickness) glass fiber filter was designed with your application needs in mind. Specific design features include: Meets the ANSI/SBS1-2004 through ANSI/SBS 4-2004 standard dimensions to ensure automation compatibility Rigid sidewalls make the plate ideal for automation handling Wide skirt easily accommodates bar codes Individual filter discs are sealed in the w…
The fluid guard is manufactured from thermoformed polystyrene, non-sterile and easily snaps to the base of the filter plate. The unique design enables the guard to be applied manually or robotically to the plate. The guard serves to protect laboratory furniture and equipment from hazardous or radioactive materials.