Environmental Products & Reviews
Environmental monitoring and testing assess the quality of our air, water, soil, and overall ecosystems. Using advanced technologies and analytical methods, environmental scientists collect and analyze samples to measure levels of pollutants, contaminants, and other factors impacting environmental health. By monitoring changes over time and identifying potential risks to human health, this field plays a vital role in informing policy decisions and implementing effective mitigation strategies. Explore how environmental monitoring and testing contribute to safeguarding our planet's well-being and promoting sustainable development.
Selected Filters:
Chemical Standards
Agilent TechnologiesGC/MS Test and Performance Samples Agilent J&W GC Column Test StandardsLC and LC/MS Standards GPC/SEC and GFC Calibration Standards Amino Acids Standards and Reagents CE Standards and Reagents ICP-MS Standards UV-Vis Standards and Reagents Application Specific Standards Residual Solvent Standards SampliQ QuEChERS Standards GC Instrument Evaluation Analyzer Kit Standards GC Instrument Installation and Calibration Standards
Direct Connect Liners
Agilent TechnologiesAgilent's Direct Connect Liners provide maximum recovery and minimal decomposition of active compounds for methods requiring splitless injection, such as EPA 8270.
EI and CI Ion Sources
Agilent TechnologiesThe ion source operates by electron ionization (EI) or chemical ionization (CI). The sample enters the ion source from the GC/MSD interface. Electrons emitted by a filament enter the ionization chamber, guided by a magnetic field. The high-energy electrons interact with the sample molecules, ionizing and fragmenting them. The positive voltage on the repeller pushes the positive ions into the lens stack, where they pass throug…
Flip Top Inlet Sealing System
Agilent TechnologiesAgilent’s new Flip Top Inlet Sealing System is a device designed to allow the user to safely and reliably change an inlet liner in as little as 30 seconds without tools in a consistent leak-free manner.
General Purpose Septa
Agilent TechnologiesAgilent’s General Purpose Septa are made from an enhanced injection-molded silicone rubber material.
Graphite Ferrules
Agilent TechnologiesAgilent offers a comprehensive selection of ferrules made of different materials and configurations for a leak-free connection between the column and injector. Graphite ferrules can withstand temperatures as high as 450 °C.
Klamp Flanges & Fittings
Agilent TechnologiesEmploying the easy release clamping design, these fittings offer a quick and simple solution to vacuum system design and assembly. Bakeable to 150º C when using Viton O-Rings, these fittings are ideal for roughing or high vacuum applications.
HTS and HTC PAL Syringes
Agilent TechnologiesHTS and HTC PAL Syringes To better serve Agilent instrument users who choose CTC Analytics autosamplers for high-throughput and flexible sample introduction, Agilent has partnered with CTC to provide a fully integrated system, including CTC-approved x-type syringes designed specifically for HTS and HTC PAL.
HTS and HTC PAL Valve Supplies
Agilent TechnologiesHTS and HTC PAL Valve Supplies To better serve Agilent instrument users who choose CTC Analytics autosamplers for high-throughput and flexible sample introduction, Agilent has partnered with CTC to provide a fully integrated system, including CTC-approved valve supplies.Whether your HTS or HTC PAL autosampler uses the Agilent proprietary Rheodyne high-pressure 600-bar injection valve or Valco Cheminert injection valves, Agil…
Hydrocarbon Removal Traps
Agilent TechnologiesOur Hydrocarbon Traps allow you to refill your trap and remove extremely low levels of hydrocarbons. Big Hydrocarbon Traps (BHT) are ideal for bulk purification applications or where several instruments are plumbed from a single gas source. Hydrocarbon Removal S-Traps are filled with 40/60 mesh activated charcoal and can be reconditioned. Capillary Grade Hydrocarbon Traps (HT3) feature extremely high surface area, are coconu…
Hydrocarbon/Moisture Traps
Agilent TechnologiesOur hydrocarbon/moisture traps offer you flexibility -- refill your trap and remove extremely low levels of both moisture and hydrocarbons.
Indicating Oxygen Traps
Agilent TechnologiesAgilent's Indicating Oxygen Trap is designed to be used in conjunction with any of our high capacity, non-indicating oxygen traps. When properly installed downstream from the non-indicating trap, the Indicating Oxygen Trap provides a visual indication of oxygen breakthrough before contamination reaches sensitive system components. Unlike adsorbent materials utilized in competitive products, our indicating media can be exposed…
Internal and External Split Vent Trap
Agilent TechnologiesCapture contaminants released by split injection systems Split vent traps capture contaminants released by split injection systems. Remember to replace the split vent cartridges every six months.An internal split vent trap is factory installed to ensure the split vent line does not clog, creating system errors or expensive repairs. Replacement cartridges are available. The optional external trap provides additional protecti…
Long-Life Non-Stick Septa
Agilent TechnologiesAgilent now treats each premium 11mm inlet septa to eliminate sticking in the GC inlet. With our premium non-stick septa, you'll never have to scrape bits of septum out of your inlet. Agilent's premium septa also have a recess on the injection side, to guide the syringe needle to the same point with every injection.
Non-Stick Septa (BTO)
Agilent TechnologiesBleed and Temperature Optimized Non-Stick Septa (BTO) Agilent now treats each premium 11 mm inlet septa to eliminate sticking in the GC inlet. With our premium non-stick septa, you'll never have to scrape bits of septum out of your inlet. Agilent's premium septa also have a recess on the injection side, to guide the syringe needle to the same point with every injection.
Oxygen/Moisture Traps
Agilent TechnologiesOxygen/moisture adsorbents team up to give you two functionalities in the same trap. Unlike some oxygen/moisture traps, these traps are disposable. Consider the safety, performance, and cost advantages of the Agilent capillary grade oxygen/ moisture traps (0T3) when comparing to heated, catalytic traps. The Agilent OT3 Trap contains a highly active, metal-containing, scrubbing material in an inert, aluminum body. This materi…
Purge and Trap Supplies
Agilent TechnologiesFind supplies for the following Teledyne Tekmar purge and trap instrumentation
QuickSwap Restrictors
Agilent TechnologiesAgilent's QuickSwap Capillary Flow Technology module and pre-swaged fused silica tubing restrictors can increase the productivity of your Agilent 5973N and 5975 inert MSD systems, allowing you to change columns without venting the MSD. QuickSwap not included.
SilTite (Metal) Ferrules
Agilent TechnologiesSilTite (Metal) Ferrules Agilent offers a comprehensive selection of ferrules made of different materials and configurations for a a leak-free connection between the column and injector. SilTite ferrules are used with Agilent Ultimate Union and other Capillary Flow Technology products, including the Purged Effluent Splitter (G3180B), Deans Switch device (G2855B), and QuickSwap Mass Spec Interface (G3185B).
Split/Splitless Inlet Gold Seals
Agilent TechnologiesEven small leaks in the split/splitless injection port can reduce system sensitivity, cause poor signal to noise ration, increase column bleed, and even shorten column lifetime. Using a patent pending manufacturing process, our inlet gold seals eliminate tiny leaks from machining that can negatively impact your GC performance.
Tubing for GC Applications
Agilent TechnologiesAgilent high-quality copper, stainless steel, and UltiMetal Plus tubing are manufactured and cleaned for chromatographic use. Agilent Tubing comes in different lengths and depending on your flow requirements, are available in 1/16 inch, 1/8 inch, or 1/4 inch. UltiMetal Plus tubing comes in 1/16 inch for inert environments.
Vespel Ferrules
Agilent TechnologiesAgilent offers a comprehensive selection of ferrules made of different materials and configurations for a a leak-free connection between the column and injector. Graphite-Vespel ferrules can withstand temperatures as high as 280 °C.
Vials 4 mL Screw Top
Agilent Technologies4 mL Screw Top Vials, Caps and Septa 4 mL screw top glass vials are a custom fit to Agilent 6850 autosampler tray (G2880A) for use as sample as well as wash vials. Vials with fill marks are also appropriate for use as wash vials and waste vials in 7673 and 7683 autosamplers. These vials can also be used in Perkin-Elmer Autosystem GC, Waters 48 position tray autosampler, Shimadzu A0C-14/1400, LC-10A and the SIL-2AS. Use th…
Vials Convenience Packs
Agilent TechnologiesConvenience Vial and Cap Packs Convenience packs are an easy way to use one part number and get 500 vials and caps with septa installed. Packed in our six drawer reusable blue plastic cabinet, the vials, caps and septa are kept handy and dust-free.