Accel-Amplicon™ Sample_ID Panel (48 reactions)
Swift Biosciences, IncSimply track and manage samples within and between studies.
Environmental monitoring and testing assess the quality of our air, water, soil, and overall ecosystems. Using advanced technologies and analytical methods, environmental scientists collect and analyze samples to measure levels of pollutants, contaminants, and other factors impacting environmental health. By monitoring changes over time and identifying potential risks to human health, this field plays a vital role in informing policy decisions and implementing effective mitigation strategies. Explore how environmental monitoring and testing contribute to safeguarding our planet's well-being and promoting sustainable development.
Simply track and manage samples within and between studies.
The CI-340 Handheld Photosynthesis System is a field-ready, lightweight and portable gas exchange monitoring instrument that is easy to operate in the lab or the field.
Robust Results for VOCs and Residual SolventsIncreased temperature limit speeds run times and re-equilibrationPopular choice for residual solvent testing (USP Monograph )Widely used to separate volatile organic flavor and fragrance additives and residual solvents in industrial or pharmaceutical products (OVIs)Equivalent to USP phase G43Recommended UseEPA Methods (501.3, 502.2, 503.1, 524.2, 601, 602, 624, 8010, 8015, 8020, 802…
Drop-In Performance for Chlorinated Pesticides by GC/ECDWhy Pesticide Labs Are Making The SwitchGuaranteed, direct replacement to Restek® Rtx®-CLPesticides columnsResolve multiple chlorinated pesticide classes on one pair with enhanced, fine-tuned selectivityMeet requirements for 7 EPA methods by GC/ECD (8081, 8082, 8151, 504, 505, 508, and 552)Instantly save on every ZB-CLPesticides column and kit with everyday low pricingRec…
Low Bleed Performance for GC/MSVery low bleed (MS Certified) especially suited to high sensitivity GC/MSImproved signal-to-noise ratio for better sensitivity and mass spectral integrityExtremely inert for active compounds such as drugs, pesticides, acids, and basesLower Overall Column ActivityActivity is a key measure of column quality. ZB-1ms columns are aggressively tested to ensure full deactivation.Recommended Applications…
Low Polarity for a Wide Range of SeparationsVersatile column recommended for a wide range of applicationsGreat column for unknown samplesResilient to dirty samples – long column lifeRecommended UseAlkaloids, Dioxins, Drugs, Essential Oils/Flavors, FAMEs, Halo-hydrocarbons, PCBs/Aroclors, Pesticides/Herbicides, Phenols, Residual Solvents
Low Bleed, Intermediate Polarity Selectivity for GC/MSIntermediate polarity column for high molecular weight analysisInert to minimize analyte adsorption, improve efficiency, and reproducibilityMore rugged (longer column life) than other polar phasesExcellent for trace analysis with bleed-sensitive detectors (MS, FID, ECD, NPD)Recommended UseAmines, Aroclors, Drugs, EPA Methods (508, 608, 8081, 8141, 8151), Pesticides, Pharmac…
Performance Up to 430 °CRugged, high temperature stable (430 °C), polyimide-coated fused silica phaseRobust column performance for high temperature bake outsTrue boiling point separation for hydrocarbon distillation methodsRecommended for chemists struggling with high boilers, contaminants, or carry-oversR&D 100 Award-Winning Technology for High Temp TestingWith advanced polymer bonding technology and specialized high temperat…
Rugged Performance Up to 430 °CRugged, high temperature stable (430 °C), polyimide-coated fused silica phaseRobust column performance for high temperature bake outsRecommended for chemists struggling with high boilers, contaminants, or carry-oversWith advanced polymer bonding technology and specialized high temperature polyimide coating, Zebron Inferno columns offer enhanced performance where other columns fail. See how Infern…
Alternate Selectivity for Mid-Polarity AnalysesFast run and re-equilibration times for enhanced sample throughput and productivityProvides alternate selectivity to phenyl phases with similar polarityRecommended UseAlcohols, Amines, Aromatic Hydrocarbons, Drugs, Esters, PAHs, PCBs, Pharmaceutical Intermediates, Phenols, Solvents, Steroids, TMS Sugars, Tranquilizers
Improved Resolution for Free Fatty AcidsPopular choice for food industry method developmentHigh polarity column with excellent thermal and chemical stabilityImprove peak shape for underivatized acids, organic acids, free fatty acids, and alcoholsBonded, solvent rinsable nitroterephthalic acid phaseRecommended UseAcrylates, Alcohols, Aldehydes, Free Fatty Acids, Ketones, Organic Acids, Phenols, Volatile Free Acids
Inferno: Rugged Performance Up to 430 °CNon-metal si-arylene low bleed phase stable to 400 ˚CProvides alternate selectivity to 5% phenyl phasesOften used for confirmation of pesticides, PCB, or other environmental samplesRobust column performance for high temperature bake outsR&D 100 Award-Winning Technology for High Temp TestingWith advanced polymer bonding technology and specialized high temperature polyimide coating, Zebron…
Inferno: Rugged Performance Up to 430 °CFirst non-metal, enhanced durability 35% phenyl phase witih 400 °C temperature stabilityGreat for high molecular weight compoundsRobust column performance for high temperature bake outsRecommended for chemists struggling with high boilers, contaminants, or carry-oversR&D 100 Award-Winning Technology for High Temp TestingWith advanced polymer bonding technology and specialized high temper…
Pirkle-brush Concept Chiral HPLC ColumnsChirex® HPLC columns utilizes Pirkle-brush concept for direct and indirect resolution of enantiomeric amines, alcohols, carboxylic acids, hydroxy acids, amino acids, ketones, lactones, ethers, esters, and other biologically active compounds. Chirex HPLC columns are available in eleven different stationary phases and offer:High enantioselectivityEasy scale-up from analytical to preparativ…
Guaranteed Replacement to Inertsil HPLC ColumnsProdigy™ columns have been developed as alternatives to the Inertsil® 3μ ODS-3, 5μ C8, C8-3, Phenyl-3, ODS-2, ODS-3 and ODS-3V packings. These phases represent a major advance in the analysis of basic, acidic and amphoteric compounds.