Foresight™ UNOsphere™ S RoboColumn Unit #7324814
Bio-Rad1 row of 8 columns, 600 µl, RoboColumn unit prepacked with UNOsphere S strong cation exchange chromatography media
Environmental monitoring and testing assess the quality of our air, water, soil, and overall ecosystems. Using advanced technologies and analytical methods, environmental scientists collect and analyze samples to measure levels of pollutants, contaminants, and other factors impacting environmental health. By monitoring changes over time and identifying potential risks to human health, this field plays a vital role in informing policy decisions and implementing effective mitigation strategies. Explore how environmental monitoring and testing contribute to safeguarding our planet's well-being and promoting sustainable development.
1 row of 8 columns, 600 µl, RoboColumn unit prepacked with UNOsphere S strong cation exchange chromatography media
Foresight UNOsphere Rapid S RoboColumn Units are no longer available. Please use Foresight UNOsphere S or Foresight™ Nuvia™ HR-S RoboColumn Units as alternate products.
500 g, analytical grade cation exchange resin, hydrogen form, 2% crosslinkage, 200–400 dry mesh size, 75–180 µm wet bead size, ~2,700 MW limit
500 g, analytical grade cation exchange resin, hydrogen form, 12% crosslinkage, 200–400 dry mesh size, 53–106 µm wet bead size, ~400 MW limit
Pkg of 1, 12 x 53 mm, 6 ml, prepacked monolith ion exchange column, 90 mg max protein load, 0.5–8.0 ml/min flow rate, operating pressure 700 psi
1 row of 8 columns, 600 µl, RoboColumn unit prepacked with UNOsphere Rapid S strong cation exchange chromatography media
Pkg of 1, 15 x 68 mm, 12 ml, prepacked monolith ion exchange column, 180 mg max. protein load, 0.5–8.0 ml/min flow rate, operating pressure 700 psi
Pkg of 1, 12 x 53 mm, 6 ml, prepacked replacement column, 90 mg max. protein load, 0.5–8.0 ml/min flow rate, operating pressure 700 psi
100/120 V, carousel-type fraction collector, 80 tube capacity, for use in chromatographic separations
1 row of 8 columns, 200 µl, RoboColumn unit prepacked with UNOsphere Q strong anion exchange chromatography media
1 row of 8 columns, 600 ul, RoboColumn unit prepacked with UNOsphere Q strong anion exchange chromatography media
1 row of 8 columns, 200 µl, RoboColumn unit prepacked with UNOsphere SUPrA affinity chromatography resin
1 row of 8 columns, 600 µl, RoboColumn unit prepacked with UNOsphere SUPrA affinity chromatography resin
Pkg of 1, 250 x 4.0 mm, prepacked HPLC carbohydrate analysis column, calcium form, 9 µm particle size, 8% cross linkage, pH range 5–9
Pkg of 1, 300 x 7.8 mm, prepacked HPLC carbohydrate analysis column, calcium form, 9 µm particle size, 8% cross linkage, pH range 5–9
Pkg of 1, 300 x 7.8 mm, prepacked HPLC carbohydrate analysis column, calcium form, 25 µm particle size, 4% cross linkage, pH range 5–9
Pkg of 1, 300 x 7.8 mm, prepacked HPLC carbohydrate analysis column, silver form, 25 µm particle size, 4% cross linkage, pH range 6–8
Pkg of 1, 300 x 7.8 mm, prepacked HPLC carbohydrate analysis column, lead form, 9 µm particle size, 8% cross linkage, pH range 5–9
Pkg of 1, 100 x 7.8 mm, prepacked HPLC organic acid and alcohol column, hydrogen form, 9 µm particle size, 8% cross linkage, pH range 1–3
Maximizing potential with SpatialOMx ® : Balancing ESI & MALDI with no sacrifices.
Automate labor-intensive and time-consuming beer, cider, malt, and wort testing with the Thermo Scientific™ Gallery™ Plus Beermaster Discrete Analyzer. Using discrete cell technology, the analyzer simultaneously automates the determination of analytes including beta-glucan, FAN, and SO2 from the same sample.
Employ the most widely used MS phase in gas chromatography with the 5% phenyl phase Thermo Scientific™ TraceGOLD™ TG-5MS GC Column.
Our columns represent a leap forward in performance, delivering low bleed and superior inertness. Select from our comprehensive portfolio of Thermo Scientific GC columns that meet all of your analytical needs and achieve reliable, reproducible results for your gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS) applications.
Having trouble resolving your compounds using your C18 column? The new Thermo Scientific Accucore Biphenyl LC column is your solution for: Aromatic & moderately polar analytes, Drugs of abuse, Steroids Now you can stop struggling with unresolved peaks, long run times, and poor lot-to-lot consistency. Obtain unique selectivity for aromatic and moderately polar analytes using Accucore Biphenyl LC Columns. These columns have opti…