Separations Products & Reviews
Separations is a fundamental scientific discipline focused on the isolation and purification of components from mixtures. Through techniques such as chromatography, distillation, and filtration, separations scientists separate substances based on their physical or chemical properties. This field plays a crucial role in various industries, including pharmaceuticals, food and beverage testing, environmental science, materials research, and more. Explore how separations techniques enable precise analysis, quality control, and the development of innovative products.
Selected Filters:
3M™ Empore™ C8-HD 1ml Cartridge
3M BioanalyticalFunctional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
3M™ Empore™ C8-SD 1ml Cartridge
3M BioanalyticalFunctional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
3M™ Empore™ C18-SD 1ml Cartridge
3M BioanalyticalFunctional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
3M™ Empore™ C8-SD 3ml Cartridge
3M BioanalyticalFunctional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
3M™ Empore™ C18-SD 3ml Cartridge
3M BioanalyticalFunctional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
3M™ Empore™ UR-SD 3ml Cartridge
3M BioanalyticalThis chemistry promotes high retention of a wide range of analytes, reducing method development time and facilitating a generic approach to sample preparation.
3M™ Empore™ C18-SD 6ml Cartridge
3M BioanalyticalFunctional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions. Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte. The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.
3M™ Empore™ SDB-XC 6ml Cartridge
3M BioanalyticalSDB-XC is a poly(styrenedivinylbenzene) copolymer used as a reversed phase sorbent for solid phase extraction. SDB-XC is not bonded to silica but is a 100% copolymeric particle that is spherical, porous and cross-linked. It does not exhibit the secondary cationic (silanol) interactions and pH limitations common to bonded silica sorbents, so it offers more predictable and reproducible reversed phase interaction.
Empore™ Accessory Vacuum Manifold for 96 Well Plates
3M BioanalyticalThe Empore™ High Performance Extraction Disk Plate differs in design from plates offered by other manufacturers and requires a specific vacuum manifold. Manifolds supplied by different plate manufacturers are specific to the design of their plates and cannot generally be used with plates from other manufacturers. In some cases, the use of spacers to raise/lower the height of a collection device inside the manifold may overco…
Empore™ Accessory Replacement Gasket for 96 Well Plate vacuum Manifold
3M BioanalyticalReplacement gaskets are available with the vacuum manifold assembly. The gasket can become worn over time and the seal between the plate and the manifold will be affected. This may result in poor vacuum pressure and negatively effect flow rates. The gasket should be checked regularly and replaced when it becomes worn.
Empore™ Accessory Sealing Tape Pad for 96 Well Plates
3M BioanalyticalEmporeTM Tape Pads are intended for sealing unused portions of a 96-well solid phase extraction plate during vacuum processing to enable vacuum to be uniformly applied to each well being used. Use a clean sheet each time for maximum sealing ability. Note: these tape sheets are not intended for sealing collection plates prior to sample injection because the adhesive may clog the injection needle.
Empore™ Accessory Filter Aid 400
3M BioanalyticalEmpore Filter Aid 400 has been shown to improve flow rates and recoveries for separation and filtration of water samples containing suspended solids. When placed on top of the Empore™ Extraction Disk at a depth of about 1 cm, Empore™ Filter Aid 400 acts as depth filter to inhibit the migration of suspended solids to the surface of the disk. This reduces extraction time and improves rates and recovery of analytes.
Cyclograph Deluxe Centrifugal Chromatography Device
Analtech Inc.The CycloGraph system is a centrifugally accelerated device for performing preparative thin layer radial separations. The separations occur quickly (within 20 minutes) with no need for scraping separated bands as with traditional Thin Layer Chromatography. Principle of Operation The compound to be separated is applied as a solution inside the adsorbent ring of the pre-cast Rotor (Analtechs prepared consumable for this device)…
Plates - Silica Gel GF 250 um 10x20cm scored (25 plates/box)
Analtech Inc.Silica Gel G & GF UNIPLATES are the most widely used silica gel TLC plates. No organic substances are added to these products, thus making them compatible with sulphuric acid charring visualization. These plates are commonly scraped from the glass backing to isolate separated components for other analytical procedures.
Plates - Silica Gel GF 250 um 20x20cm (25plates/box)
Analtech Inc.Silica Gel G & GF UNIPLATES are the most widely used silica gel TLC plates. No organic substances are added to these products, thus making them compatible with sulphuric acid charring visualization. These plates are commonly scraped from the glass backing to isolate separated components for other analytical procedures.
Plates - Silica Gel G 250 um 20x20cm (25 plates/box)
Analtech Inc.Silica Gel G & GF UNIPLATES are the most widely used silica gel TLC plates. No organic substances are added to these products, thus making them compatible with sulphuric acid charring visualization. These plates are commonly scraped from the glass backing to isolate separated components for other analytical procedures.
Reversed Phase Plates - RPS 250 um 20x20cm (25 plates/box)
Analtech Inc.Analtech Reversed Phase Separation (RPS) UNIPLATES offers several advantages over the bonded RP18 type TLC plates. RBS UNIPLATES are a hydrocarbon impregnated silica gel. The hydrocarbon is adsorbed onto the silica gel surface and is not chemically anchored to the particle. The main advantages of the hydrocarbon impregnated Reversed Phase plate are compatibility with aqueous solutions and parallel behavior to most C18 HPLC pac…
Taper plates - Silica Gel G 20x20cm Prep-scored UNIPLATE-T Taper Plate (25 plates/box)
Analtech Inc.The UNIPLATE-T Taper Plate, invented and patented by Analtech, is a unique preparative TLC plate that provides unusually high resolution for a preparative layer. It has a wedge-shaped adsorbent layer, progressing from 300 microns (bottom) to 1700 microns (top). Below the silica layer is a 700-micron-thick pre-absorbent zone provided for easier sample application and higher sample resolution.
Glass Rectangular Developing Chamber for 20x20cm plates (with lid)
Analtech Inc.Analtech's glass TLC developing chambers provide optimum developing conditions for a variety of TLC plate sizes and shapes. Precision ground surfaces provide tight seals between tanks and glass covers, permitting complete saturation of chambers with solvent vapour for uniform development of chromatograms.
Glass Cylindrical Developing Chamber for 10x10cm plates
Analtech Inc.Analtech's glass TLC developing chambers provide optimum developing conditions for a variety of TLC plate sizes and shapes. Precision ground surfaces provide tight seals between tanks and glass covers and permit complete saturation of chambers with solvent vapour for uniform development of chromatograms
TLC AutoSpotter, 110 V/60 Hz
Analtech Inc.The TLC AUTOSPOTTER is a semi-automated device used to apply samples on Thin Layer Chromatography plates. The instrument eliminates the need for manual sample application and can be used to apply up to 18 samples at a time.
HySphere™ C8 EC-SE
Spark System Solutions B.V.Spark has introduced the second edition of HySphere™ C8 End-Capped cartridges. We have selected a new perfect Spherical sorbent material with a narrow particle size distribution. This will create less back pressure during operation and allows you to run higher flow rates compared to our current HySphere™ C8 (EC). The new cartridge has the same excellent characteristics such as high extraction capacity and selectivity
Corning® 150 mL Bottle Top Vacuum Filter, 0.45 µm Pore 13.6cm² CA Membrane, Fits 33 mm Diameter Necks, Sterile, 48/Case
Corning Life SciencesFits plastic or glass media bottles with 33mm neck sizes. Cellulose acetate (CA) membranes provide fast flow rates and low protein binding and are good for filtering cell culture media. Angled hose connector simplifies vacuum line attachment. Individually packaged, sterile and certified nonpyrogenic. Each system has the membrane material and pore size printed on the unit and is color-coded by membrane type for easy produ…
XTRX ™ Extraction Columns
Analtech Inc.The XTRX ™ columns can be used for everything from drug testing to environmental pollutants screenings and is designed for use in the Dupont Prep ™ 1 Automated Sample Processor, the XTRX ™ 4 Automated Sample Processor or any vacuum box. The XTRX ™ columns were previously manufactured by Creative Technology Systems, Inc. Since 1961 Analtech has been manufacturing quality thin layer chromatography plates, providing friendly and…