33 mm Non-sterile Millex Filter Units
MerckMillex-GP Filter for Samplicity G2, 0.22 µm, PES 33 mm, non-sterile
Sample preparation can improve the quality and speed of separation techniques. Products to assist sample preparation include filtration equipment, evaporators, membranes and sieves.
Millex-GP Filter for Samplicity G2, 0.22 µm, PES 33 mm, non-sterile
The solid phase extraction (SPE) workstation can be used on Xiril pipetting workstations for automated nucleic acid purification based on vacuum technology. All pipetting steps of several different nucleic acid purification kits can be automated on a Xiril liquid handling workstation. Xiril’s very space saving SPE vacuum station comprises two positions, one in the front for washing steps and another in the back for the elution…
The magnetic bead separation device Magnetic PlateX can be used with a Xiril pipetting workstation for automated nucleic acid purification based on the magnetic beads technology. Speed up the process of nucleic acid purification with a magnetic beads kit using the Magnetic PlateX on a Xiril robotic workstation. All pipetting steps are taken over by the robot and the plate gripper “Plate GripX” automatically carries out the tra…
The Tube-ScanX LR is the new scanner for the automated reading of barcodes on tubes on a Xiril liquid handling robotic workstation. The barcode scanner “LR” is equipped with a laser reader for a fast record of all barcodes on tubes without interruption while reading. The laser camera with autofocus is mounted fix on the worktable. It doesn’t have to be moved whereas the tube holding racks are drawn with two of the pipetting ad…
The Plate-ScanX enables microplate identification for data tracking in an automated liquid handling process on a Xiril robotic workstation. Xiril’s plate scanner device allows reading of 1D and 2D barcodes on the side of microplates. The plate gripper of the Xiril liquid handling workstation picks up the plate and presents it in front of the barcode scanner camera.
For Buffers, Tissue Culture Media, and Other Biological Fluids. Newer technology recommended for simplified scale-up High filtration area and compact size are ideal for upscale trials Minimal hold-up volume Good wettability for reliable integrity test Sealed membrane and housing uses fusion technology to eliminate potential extractables Gamma sterilized, non-pyrogenic, and provided with a removable filling bell (except sanit…
For Cost-Effective Filtration of Buffers, Tissue Culture Media, and Other Biological Solutions. Newer technology recommended for simplified scale-up Disposable design reduces labor costs associated with assembling, cleaning, and testing stainless steel filter holders Encapsulated format for ease of use Extended life with built-in MachV asymmetric prefilter layer for maximum flow and throughput performance Low adsorption and hi…
Superior Bead Recovery and Low Levels of False Positives Ensure Assay Reproducibility. Smooth well wall provides efficient bead recovery, ensuring reproducible results lot after lot High performance membrane does not trap microspheres in the membrane matrix In serological assays, Supor® membrane effectively removes IgG complexes, thus reducing nonspecific reactivity of the microspheres and reducing false positives New well des…
Robust Chemical Resistance Provides Compatibility with Harsh Organics. Chemically resistant materials provide a stable platform to process samples in organic solvents Inert materials of construction ensure complete recovery of samples and low non-specific binding New well design results in faster, more uniform filtration rates across the plate and reduces hold-up volume Innovative outlet tip geometry provides direct flow of sa…
The AcroPrep™ Advance filter plates for lysate clearance effectively remove cellular debris quickly and allow for the use of additional wash steps to maximize sample recovery. Filtration can be accomplished by either vacuum manifold or centrifugation, ultimately maximizing your choice in protocols. The purification of biomolecules (DNA, RNA and proteins) from prokaryotic and eukaryotic cell lines can be problematic. The AcroP…
The SPD131DDA enhanced performance SpeedVac concentrator is a simple to use, bench-top concentrator. It is economical and is ideal for personal or low through-put evaporation of strong acids, bases and aggressive organic solvents, approved for combinatorial chemistry. Digital programming enhances usability. Product Detail The SPD131DDA is designed to handle the rigors and solvents of combinatorial chemistry. It incorpo…
High durability, heavy-duty design incorporates a ceramic bearing magnet assembly for maximum chemical resistance and reliability. A high evaporation rate is achieved by extra-wide tubing and an extra large mouth glass condensation flask. Customize your concentrator configuration to your application. Product Detail The Express SC250 is a drug discovery modular SpeedVac concentrator designed for the rigors of industrial u…
The BluePippin is a preparative electrophoresis platform for collection of size-selected DNA or protein samples. The system automates DNA or protein size selection using disposable, pre-cast agarose cassettes to extract fractions according to user-defined software input. Samples are electro-eluted from agarose and collected in buffer. The platform is used for the construction of next-gen sequencing libraries, or upstream of p…
The 6875 Freezer/Mill® is a large cryogenic mill that accommodates sample sizes ranging from 0.1 - 100 grams. Specifically designed for cryogenic grinding and pulverizing tough and/or temperature sensitive samples in a grinding vial immersed in liquid nitrogen. The new high resolution display is user-friendly and shows the each stage of the grinding process. It also shows the Run history, Training videos and manuals and a…
The Shatterbox® is a heavy duty, Swing Mill that is designed for pulverizing dry, brittle samples and slurry grinding. It features a sound-proof enclosure and a timer display that counts down the minutes and seconds remaining in the process. It accommodates sample sizes ranging from 2 - 100 grams and is capable of grinding Cement, Soils, Ceramics, Slag, Rocks, Minerals, Ores, Pharmaceuticals, Sulfur Pellets, Dried Plant Ma…
The 6875D Freezer/Mill® is a high-throughput, dual chamber cryogenic grinder with a self-contained liquid nitrogen tub and insulated case. Specifically designed for cryogenic grinding and pulverizing of tough and/or temperature sensitive samples in a grinding vial immersed in liquid nitrogen. This mill chills samples in liquid nitrogen then pulverizes them with a magnetically driven impactor. The new high resolution displa…
The 8000D Mixer/Mill® is a dual clamp, high-energy ball mill that grinds dry, brittle samples such as Rocks, Minerals, Sand, Cement and Slag. It can also be utilized for mechanical alloying, slurry grinding, blending powders and mixing emulsions. It accommodates sample sizes ranging from 0.2 - 10 grams per vial and has a figure eight motion that has been proven to be more efficient than side-to-side or planetary motion fou…
The LH96 can be configured to combine multiple sample prep steps into one versatile, efficient and automated device. Quite literally, what used to take hours or days can now be completed in a matter of minutes, and without attendance. The LH96 integrates a core homogenizing platform, capable of efficiently processing a wide variety of samples from 5mL to 50mL tubes, with fully customizable liquid handling capabilities. Patent…
Ready-to-use dialysis device with a broad built-in range of precise MWCO's and all the needed accessory components built in for ultimate convenience. Features leak proof and re-sealable snap-on cap for sampling, colour coded dot for MWCO, broad floatation disk for buoyancy, 6 volume-specific size, 2 membrane types- biotech grade regenerated cellulose (RC) and biotech grade cellulose ester (CE).
miVac is a range of centrifugal vacuum concentrators and freeze driers capable of removing water and organic solvents from a variety of sample formats including tubes, microplates, and vials. miVac concentrators come in 2 sizes, the smaller Duo and a larger Quattro. There is a choice of vacuum pump and rotor according to application and sample format. To speed concentration built-in special runs for working with water and…
digestec DAB-2/3, to Digest the Hardest Samples. The traditional “stainless steel bomb” with its PTFE insert is being increasingly replaced by the microwave for most routine applications. However, when it comes to difficult-to-digest samples such as silicon carbide or alpha-aluminium oxide, such systems remain of inestimable value to users. The great advantage of these systems lies in the fact that the digestion period can…
The MagNA Pure LC Cooling Block, LC Centrifuge Adapters, holds 32 LightCycler® Centrifuge Adapters containing LightCycler® Capillaries (20 µl). The Cooling Block is designed to cool the capillaries during automated PCR setup by the MagNA Pure LC Instrument. In addition, the Cooling Block holds fifteen 1.5 ml reaction tubes (e.g., for master mixes). The stage of the MagNA Pure LC Instrument includes a cooling area, which is des…
The MagNA Pure LC Cooling Block, LC Sample Carousel holds one LightCycler® Sample Carousel (all formats) containing LightCycler® Capillaries. The Cooling Block is designed to cool the capillaries during automated PCR setup by the MagNA Pure LC Instrument. In addition, the Cooling Block holds sixteen 1.5 ml reaction tubes (e.g. for master mixes). The stage of the MagNA Pure LC Instrument includes a cooling area, which is design…
Application The MagNA Pure LC Cooling Block, Reaction Tubes, is used for placing thirty-two 1.5 ml reaction tubes, with screw caps, on the stage of the MagNA Pure LC Instrument. This Cooling Block can be combined with either the MagNA Pure LC Cooling Block, LC Centrifuge Adapters, or 96-well PCR Plate. The stage of the MagNA Pure LC Instrument includes a cooling area that is designed for various post-elution pipetting proces…
Application The MagNA Pure LC Cooling Block, A-Ring holds one or two A-Rings with bar codes. Application of the corresponding Post Elution Module of the MagNA Pure LC Software results in automatic filling of the A-Rings with purified nucleic acids and compatible PCR reagents, which are also positioned on the Cooling Block. The A-Rings are then ready to be transferred to an instrument platform for testing. The stage of th…