Accessories Products & Reviews

25

Accessories

Product Filter

Explore by Field
Sample Preparation
Accessories
Explore by Company

Ratings

Search

Selected Filters:




3M™ Empore™ C8 90 mm Disk

3M Bioanalytical

Commonly used for the solid phase extraction of analytes from complex sample matrices.  A variety of functional groups, such as octadecyl (C18) and octyl (C8) can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent…

0.0/5.0
|0 Reviews

3M™ Empore™ C18 90 mm Disk

3M Bioanalytical

3M bioanalytical's Empore c18 90 Disk-Commonly used for the solid phase extraction of analytes from complex sample matrices.  A variety of functional groups, such as octadecyl (C18) and octyl (C8) can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular me…

0.0/5.0
|0 Reviews

3M™ Empore™ SDB-XC 90 mm Disk

3M Bioanalytical

SDB-XC is a poly(styrenedivinylbenzene) copolymer used as a reversed phase sorbent for solid phase extraction.  SDB-XC is not bonded to silica but is a 100% copolymeric particle that is spherical, porous and cross-linked.  It does not exhibit the secondary cationic (silanol) interactions and pH limitations common to bonded silica sorbents, so it offers more predictable and reproducible reversed phase interaction.

0.0/5.0
|0 Reviews

3M™ Empore™ SDB-RPS 90 mm Disk

3M Bioanalytical

SDB-RPS is a poly(styrenedivinylbenzene) copolymer that has been modified with sulfonic acid groups to make it hydrophilic.  SDB-RPS is not bonded to silica but is a 100% copolymeric particle that is spherical, porous and cross-linked.  The sulfonation imparts unique selectivity for organic analytes that are polar in nature, such as drugs, drug metabolites, water-soluble pesticides and pesticide metabolites.  SDB-RPS is also u…

0.0/5.0
|0 Reviews

3M™ Empore™ Anion Exchange-SR 90 mm Disk

3M Bioanalytical

3M Bioanalytical's Anion-SR is a poly(styrenedivinylbenzene) copolymer that has been modified with quaternary ammonium groups.  Note that the 3M Anion-SR is not bonded to silica but is a 100% copolymeric particle that is spherical, porous and cross-linked.  The functional group imparts unique selectivity for anionic analytes, such as Endothall, Dalpon and haloacetic acids.

0.0/5.0
|0 Reviews

3M™ Empore™ Oil & Grease 90 mm Disk

3M Bioanalytical

The Oil & Grease Disk was specifically designed for EPA Method 1664 (N-Hexane Extractable Materials (HEM) and Silica Gel Treated N-Hexane Extractable Material (SGT-HEM) by Extraction and Gravimetry).  EPA Method 1664 Revision A was approved for use in the United States and published in the Federal Register on May 14, 1999.  The Oil & Grease Disk incorporates C18 sorbent particles within a hydrophobic matrix.  For EPA Method 16…

0.0/5.0
|0 Reviews

3M™ Empore™ Carbon 90 mm Disk

3M Bioanalytical

Empore Carbon Disks are designed for the extraction of volatile, highly polar, and water soluble compounds from aqueous solutions.  The Empore Carbon Disk provides all the advantages of activated carbon in a compact and thin Empore Disk.

0.0/5.0
|0 Reviews

3M™ Empore™ C8-SD Standard Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ C18-SD Standard Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ MPC-SD Standard Well Plate

3M Bioanalytical

This mixed phase chemistry, in which two primary modes of attraction are present, allows for a more efficient and selective extraction compared to traditional reversed phase techniques.  Neutral and ionized analytes can be simultaneously extracted from a complex mixture and eluted as separate fractions.  A mixed phase sorbent offers the following advantages: Eluting acidic and neutral analytes separately from basic analy…

0.0/5.0
|0 Reviews



3M™ Empore™ C8-SD Deep Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ C18-SD Deep Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ MPC-SD Deep Well Plate

3M Bioanalytical

This mixed phase chemistry, in which two primary modes of attraction are present, allows for a more efficient and selective extraction compared to traditional reversed phase techniques.  Neutral and ionized analytes can be simultaneously extracted from a complex mixture and eluted as separate fractions. A mixed phase sorbent offers the following advantages: Eluting acidic and neutral analytes separately from basic analyt…

0.0/5.0
|0 Reviews



Empore™ Accessory Vacuum Manifold for 96 Well Plates

3M Bioanalytical

The Empore™ High Performance Extraction Disk Plate differs in design from plates offered by other manufacturers and requires a specific vacuum manifold.  Manifolds supplied by different plate manufacturers are specific to the design of their plates and cannot generally be used with plates from other manufacturers.  In some cases, the use of spacers to raise/lower the height of a collection device inside the manifold may overco…

0.0/5.0
|0 Reviews


Empore™ Accessory Sealing Tape Pad for 96 Well Plates

3M Bioanalytical

EmporeTM Tape Pads are intended for sealing unused portions of a 96-well solid phase extraction plate during vacuum processing to enable vacuum to be uniformly applied to each well being used.  Use a clean sheet each time for maximum sealing ability.  Note: these tape sheets are not intended for sealing collection plates prior to sample injection because the adhesive may clog the injection needle.

0.0/5.0
|0 Reviews

Empore™ Accessory Filter Aid 400

3M Bioanalytical

Empore Filter Aid 400 has been shown to improve flow rates and recoveries for separation and filtration of water samples containing suspended solids.  When placed on top of the Empore™ Extraction Disk at a depth of about 1 cm, Empore™ Filter Aid 400 acts as depth filter to inhibit the migration of suspended solids to the surface of the disk.  This reduces extraction time and improves rates and recovery of analytes.

0.0/5.0
|0 Reviews

Reduced breakdown injection port liners

VICI AG International

Reduced breakdown liners Our improved injection port liner reduces breakdown of endrin and DDT during injections while increasing the interval between liner changes. The problem DDT and Endrin are easily degraded in the injection port; with non-deactivated liners and those filled with non-deactivated glass wool, Endrin breakdown can be as high as 98%. EPA method 8081A states "If degradation of either DDT or Endrin exceeds 15%,…

0.0/5.0
|0 Reviews