Flow Cytometry / Cell Counting Products & Reviews

Flow cytometers are used to count, sort and examine multiple characteristics of cells. Other cell analysis equipment includes image cytometers, cell counters, fluorescence-activated cell sorters (FACS), magnetic-activated cell sorters (MACS), and a range of flow cytometry assay kits. Flow cytometers can reveal information on cell viability, cell proliferation, apoptosis and cell cycle progression, as well as identify cell populations and intracellular or cell-surface molecules. Additionally, some flow cytometers, known as FACS, have an additional sorting function after analysis. Cell counters and image cytometers count live and dead cell populations and can also conduct cell proliferation assays. Find the best flow cytometers, cell counters and cell sorters in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.

Product Filter

Explore by Field
Flow Cytometry / Cell Counting
Refine your selection
Explore by Company

Ratings

Search

Invitrogen™ LIVE/DEAD™ Fixable Yellow Dead Cell Stain Kit

Thermo Fisher Scientific

The LIVE/DEAD Fixable Yellow Dead Cell Stain Kit provides the stable components to determine the viability of cells prior to the fixation and permeabilization required for intracellular antibody staining or prior to elimination of biohazardous materials using formaldehyde fixation. The amine-reactive LIVE/DEAD Fixable Yellow Stain is an amine reactive dye that binds covalently to intracellular and extracellular amines in cells…

0.0/5.0
|0 Reviews

Invitrogen™ LIVE/DEAD™ Fixable Green Dead Cell Stain Kit

Thermo Fisher Scientific

The LIVE/DEAD Fixable Green Dead Cell Stain Kit provides the stable components to determine the viability of cells prior to the fixation and permeabilization required for intracellular antibody staining or prior to elimination of biohazardous materials using formaldehyde fixation. The amine-reactive LIVE/DEAD Fixable Green Stain is an amine reactive dye that binds covalently to intracellular and extracellular amines in cells w…

0.0/5.0
|0 Reviews

Invitrogen™ LIVE/DEAD™ Fixable Red Dead Cell Stain Kit

Thermo Fisher Scientific

The LIVE/DEAD Fixable Red Dead Cell Stain Kit provides the stable components to determine the viability of cells prior to the fixation and permeabilization required for intracellular antibody staining or prior to elimination of biohazardous materials using formaldehyde fixation. The amine-reactive LIVE/DEAD Fixable Red Stain is an amine reactive dye that binds covalently to intracellular and extracellular amines in cells with…

0.0/5.0
|0 Reviews

Invitrogen™ LIVE/DEAD™ Fixable Far Red Dead Cell Stain Kit

Thermo Fisher Scientific

The LIVE/DEAD Fixable Far Red Dead Cell Stain Kit provides the stable components to determine the viability of cells prior to the fixation and permeabilization required for intracellular antibody staining or prior to elimination of biohazardous materials using formaldehyde fixation. The amine-reactive LIVE/DEAD Fixable Far Red Stain is an amine reactive dye that binds covalently to intracellular and extracellular amines in cel…

0.0/5.0
|0 Reviews

Invitrogen™ Propidium Iodide Ready Flow™ Reagent

Thermo Fisher Scientific

Propidium Iodide Ready Flow™ Reagent is a bright, easy-to-use nucleic acid stain for distinguishing dead cells from live cells in flow cytometry assays. Propidium iodide can only enter cells that have lost membrane intergrity (e.g., dead cells). Once inside, it can bind with nucleic acids, emtting a red fluorescence, which has excitation/emission maxima of 535/617 nm. Propidium iodide is commonly excited with the 488 nm laser,…

0.0/5.0
|0 Reviews

Invitrogen™ TO-PRO™3 Ready Flow™ Reagent

Thermo Fisher Scientific

TO-PRO3 Ready Flow Reagent is a bright, easy-to-use nucleic acid stain for distinguishing dead cells from live cells in flow cytometry assays. TO-PRO3 Ready Flow Reagent can only enter cells that have lost membrane intergrity (e.g., dead cells). Once inside, it can bind with nucleic acids, emitting a red fluorescence, which has an excitation/emission maxima of 642/661 nm, similar to Alexa Fluor™ 647 or allophycocyanin (APC).Fe…

0.0/5.0
|0 Reviews

Invitrogen™ SYTOX AADvanced™ Ready Flow™ Reagent

Thermo Fisher Scientific

SYTOX AADvanced Ready Flow Reagent is a high-affinity nucleic acid stain for the detection of dead cells in flow cytometry. SYTOX AADvanced Ready Flow Reagent can only enter cells that have lost membrane intergrity (e.g., dead cells). Once inside, it can bind with nucleic acids, emitting a red fluorescence, which has an excitation/emission maxima of 546/647 nm. The SYTOX AADvanced Ready Flow Reagent dye is spectrally similar t…

0.0/5.0
|0 Reviews

Invitrogen™ SYTOX™ Dead Cell Stain Sampler Kit

Thermo Fisher Scientific

SYTOX™ Dead Cell Stain Sampler Kit contains sample sizes of five nucleic acid stains to identify the most appropriate satin to work in multi-color experiments. Stains include: SYTOX Blue (for the 405 nm violet laser), SYTOX Green (for the 488 nm blue laser with green emission), SYTOX Orange (for the 532 nm green laser), SYTOX AADvanced (for the 488 nm blue laser with red emission), and SYTOX Red (for the 633/5 nm red laser).St…

0.0/5.0
|0 Reviews

Invitrogen™ Annexin V Alexa Fluor™ 488 Ready Flow Conjugate 

Thermo Fisher Scientific

Annexin V Alexa Fluor 488 Ready Flow Conjugate is a bright, easy-to-use stain for apoptosis with high affinity for phosphatidylserine (PS), which becomes exposed on the outer leaflet of cells undergoing apoptosis. The Annexin V Alex Fluor 488 conjugate is excitable at 495 nm with an emission peak at 519 nm.FeaturesStable at room temperatureConvenient, ready-to-use format—no need to dilute, weigh, or pipetteCan be added directl…

0.0/5.0
|0 Reviews

Invitrogen™ Annexin V Alexa Fluor™ 647 Ready Flow Conjugate

Thermo Fisher Scientific

Annexin V Alexa Fluor 647 Ready Flow Conjugate is a bright, easy-to-use stain for apoptosis with high affinity for phosphatidylserine (PS), which becomes exposed on the outer leaflet of cells undergoing apoptosis. The Annexin V Alex Fluor 647 conjugate is excitable at 650 nm with an emission peak at 665 nm.FeaturesStable at room temperatureConvenient, ready-to-use format—no need to dilute, weigh, or pipetteCan be added directl…

0.0/5.0
|0 Reviews