Dual-FL - CCD Based Benchtop Spectrofluorometer
HORIBA Scientific combined the world’s only CCD based benchtop spectrofluorometer with a UV-VIS spectrophotometer and created the Dual-FL. HORIBA Scientific addressed the need for speed when collecting spectral data and complete excitation-emission matrices (EEMs). Dual-FL features spectral rates as fast as 80,000 nm/s, and acquires EEMs up to a 100 times faster than any other instrument. With its sensitive cooled, back-illumi…
The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our Product Directory.
HORIBA Scientific combined the world’s only CCD based benchtop spectrofluorometer with a UV-VIS spectrophotometer and created the Dual-FL.
HORIBA Scientific addressed the need for speed when collecting spectral data and complete excitation-emission matrices (EEMs). Dual-FL features spectral rates as fast as 80,000 nm/s, and acquires EEMs up to a 100 times faster than any other instrument. With its sensitive cooled, back-illuminated CCD detector for rapid collection of emission spectra, and an excitation double monochromator for superior stray light rejection, the Dual-FL has Signal to Noise greater than 20,000:1 RMS. The simultaneous absorbance data can be used to correct inner-filter effects in measurement of high concentration samples, eliminating the need for time consuming, labourious dilutions. Of course, the Dual-FL can also be used as a stand-alone UV-VIS, meeting spectrophotometer test specs like the USP.
Dual-FL is a breakthrough instrument that allows unparalleled speed and ease of use for fluorescence spectroscopy, with the added bonus of meeting all of a lab’s UV-VIS needs.
Features
Hardware
• The only true simultaneous absorbance-fluorescence system available
• TE-cooled CCD fluorescence emission detector for rapid data acquisition up to 100 times faster than any other benchtop fluorometer
• Corrected UV-VIS absorbance detection path for stability and accuracy
• Double grating excitation monochromator for superior stray light rejection
• Matching bandpass for absorbance and fluorescence spectra
• Automatic sample changer option (two or four position)
• Compatible with flow cells and titrator
Software
• Optimized experiment set-up menus minimize user confi guration time
• Complete NIST-traceable corrected fluorescence spectra automatcally generated
• Spectral and kinetic analysis tools for both absorbance and fluorescence data
• Methods and batch protocols for automating multiple sample measurement