Mouse MCP-1 ELISA
RayBio® Mouse MCP-1 (CCL2) ELISA Kit for cell culture supernatants, plasma, and serum samples.
Antigen InformationAccession Number:
P10148
Gene ID:
20296
Gene Symbols:
CCL2; JE; MCP1; SCYA2
Protein Name & Synonyms:
C-C motif chemokine 2 (Monocyte chemoattractant protein 1) (Monocyte chemotactic protein 1) (MCP-1) (Platelet-derived growth factor-inducible protein JE) (Small-inducible cytokine A2)
Target Species:
Mouse
Assay FormatDetection Range:
3 pg/ml - 2000 pg/ml
Recommended Dilution (serum & plasma):
2 - 10 fold
Sensitivity:
3 pg/ml
Need more sensitivity? Check out the new IQELISATM kit for this target. Still not enough? Then your answer is our Ultrasensitive Biomarker Testing Service powered by SimoaTM technology.
Specificity:
This ELISA kit shows no cross-reactivity with any of the cytokines tested: Mouse 6Ckine, CTACK, Eotaxin, GCSF, GM-CSF, IL-2, IL-3, IL-4, IL-5, IL-6, IL-9, IL-10, IL-12p40, IL-12p70, IL-13, IL-17, IFN-gamma, KC, Leptin, MCP-5, MIP-1 alpha, MIP-2, MIP-3 beta, RANTES, SCF, sTNFri, TARC, TIMP-1, TNF-alpha, TPO, VEGF.
Number of Targets Detected:
1
Species Detected:
Mouse
Compatible Sample Types:
Cell Culture Supernatants; Cell Lysates; Plasma; Serum; Tissue Lysates
Design Principle:
Sandwich-based
Method of Detection:
Colorimetric
Quantitative/Semi-Quantitative:
Quantitative
Solid Support:
96-well Microplate
Product SpecificationsSize:
1, 2, or 5 x 96-Well Strip Microplate Kit
Product FeaturesAdditional Notes
- Strip plates and additional reagents allow for use in multiple experiments
- Quantitative protein detection
- Establishes normal range
- The best products for confirmation of antibody array data
Standard CurvesSpiking & Recovery ResultsLinearity ResultsApplication NotesKit Components
- Pre-Coated 96-well Strip Microplate
- Wash Buffer
- Stop Solution
- Assay Diluent(s)
- Lyophilized Standard
- Biotinylated Detection Antibody
- Streptavidin-Conjugated HRP
- TMB One-Step Substrate
Other Materials Required
- Distilled or deionized water
- Precision pipettes to deliver 2 µl to 1 µl volumes
- Adjustable 1-25 µl pipettes for reagent preparation
- 100 µl and 1 liter graduated cylinders
- Tubes to prepare standard and sample dilutions
- Absorbent paper
- Microplate reader capable of measuring absorbance at 450nm
- Log-log graph paper or computer and software for ELISA data analysis
Protocol Outline
Prepare all reagents, samples and standards as instructed in the manual.
Add 100 µl of standard or sample to each well.
Incubate 2.5 h at RT or O/N at 4°C.
Add 100 µl of prepared biotin antibody to each well.
Incubate 1 h at RT.
Add 100 µl of prepared Streptavidin solution to each well.
Incubate 45 min at RT.
Add 100 µl of TMB One-Step Substrate Reagent to each well.
Incubate 30 min at RT.
Add 50 µl of Stop Solution to each well.
Read at 450 nm immediately.
Storage/Stability
The entire kit may be stored at -20°C for up to 1 year from the date of shipment. Avoid repeated freeze-thaw cycles. The kit may be stored at 4°C for up to 6 months. For extended storage, it is recommended to store at -80°C.