Products & ReviewSeparations

MXT®-Biodiesel TG Columns

Restek has raised the bar with a new high-temperature MXT®-Biodiesel TG column line to complement their fused silica column line for biodiesel analysis. These new MXT® -Biodiesel TG columns are stable to 430°C and offer unique retention gap options that minimize dead volume and leaks. Choose either a 0.32mm column factory-coupled to a 0.53mm retention gap, or select a single unit 0.53mm column featuring Integra-Gap™, a built-…

Request Pricing
Restek Corp.

Receive your quote directly from the manufacturer.

Average Rating 5.0

|2Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Good column for D6584 method.

 

Average Rating 5.0

Application Area:

D6584 Free and Total Glycerin in Biodiesel

Column works well for this ASTM method. Column life is short (2-3 months) due to the nature of the material being analysed. Believe the sterolglucosides in the biodiesel coat the column and shorten life span. Would be nice if there was a way to extend the life of the column. Tend to loose the sensitivity of the Free Glycerin and Triglyceride peaks.

Review Date: 31 Jul 2018 | Restek Corp.

Great column ,Great results out performs next best easily.

 

Average Rating 5.0

Application Area:

Analyse trace levels of glycerides in bio diesel

The column is a lot more robust than its closest competitor and has a very quick conditioning time. This column gives us fantastic definition for Triglycerides that the other brands struggle to get close to.

Review Date: 25 Jul 2018 | Restek Corp.

Restek has raised the bar with a new high-temperature MXT®-Biodiesel TG column line to complement their fused silica column line for biodiesel analysis.

These new MXT® -Biodiesel TG columns are stable to 430°C and offer unique retention gap options that minimize dead volume and leaks. Choose either a 0.32mm column factory-coupled to a 0.53mm retention gap, or select a single unit 0.53mm column featuring Integra-Gap™, a built-in retention gap that eliminates the need for a connector. Both designs are extremely stable at high temperatures and produce fast elution times and sharp peaks for high molecular weight glycerides.


MXT®-Biodiesel TG Columns Features:

  • Fast analysis times and sharp mono-, di-, and triglyceride peaks.
  • Stable at 430 °C for reliable, consistent performance.

Column Details:

  • Siltek®-treated stainless steel
  • Length: 2, 10, 14, 15 m
  • ID: 0.32, 0.53 mm
  • df: 0.10, 0.16 μm

Product Overview

Links