Products & ReviewSeparations

Septa (11 mm)

Restek Corp.27090Available: Worldwide

for Agilent 5880A/5890/6850/6890/7890 GCs with S/SL or PTV inlets

Request Pricing
Restek Corp.

Receive your quote directly from the manufacturer.

Average Rating 4.7

|2Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Durable and cost effective.

 

Average Rating 4.3

Application Area:

Enviromental analysis

These septa work great. Very durable and don't get cored easily. It's nice that they now come individually sealed.

Review Date: 15 Jul 2020 | Restek Corp.

Restek is my preferred supplier for all my capillary GC consumables!

 

Average Rating 5.0

Application Area:

Process and product quality control

I have used Restek as my preferred supplier for capillary columns and assorted consumables for my gas chromatography needs (Agilent) for almost 20 years! They are my preferred vendor for septa, inlet liners, inlet seals and fittings, ferrules, and columns (RTX fused silica).

Review Date: 15 Jul 2020 | Restek Corp.

Thermolite Plus Septa

  • Usable to 350 °C inlet temperature.*
  • Ultra-low bleed minimizes background signal.
  • New plasma coating eliminates sticking in the injection port.
  • Precision molding ensures consistent, accurate fit.
  • Septa have a CenterGuide design to minimize coring. (Not available on 6 mm, 7 mm, 8 mm, 9.5 mm, 10 mm, and Shimadzu plug.)
  • 5 mm septa are partially predrilled for improved puncturability.
  • Preconditioned and ready to use.
  • Packaged in ultra-clean blister packs.
  • Each batch GC-FID tested.

Premium Non-Stick BTO Septa

  • Usable to 400 °C inlet temperature.*
  • New plasma coating eliminates sticking in the injection port.
  • Precision molding ensures consistent, accurate fit.
  • Septa have a CenterGuide design to minimize coring. (Not available on 9.5 mm, 10 mm, and Shimadzu Plug.)
  • 5 mm and 11 mm septa are partially predrilled.
  • Preconditioned and ready to use.
  • Packaged in ultra-clean blister packs.**
  • Each batch GC-FID tested.
  • Bleed and temperature optimized; ideal for demanding GC and GC-MS applications.

Note: Due to differences in inlet design, the actual septum temperature for a given inlet set point can vary by manufacturer. Restek recommends using only BTO septa in older Thermo TRACE and Focus GCs. For Thermo TRACE 1300/1310 GCs, this recommendation does not apply; septa can be used to their maximum recommended temperature.
*For 17 mm inlets, the maximum temperature for BTO septa is 330 °C, 290 °C for Thermolite septa, and 300 °C for Thermolite Plus septa. For all injectors, minimum recommended operating temperature for BTO septa is 250 °C.
**12.7 mm and 17 mm septa packaged in precleaned glass jars.

Product Overview

Links