Thermo Scientific LTQ Orbitrap XL
Thermo Scientific LTQ Orbitrap XL - The Most Confident Protein Identification The Thermo Scientific LTQ Orbitrap XL hybrid FTMS (Fourier Transform Mass Spectrometer) supports a wide range of applications from routine compound identification to the most challenging analysis of low level components in complex mixtures. The LTQ Orbitrap XL is based on the fast and highly sensitive Thermo Scientific LTQ XL linear ion trap and th…
The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our Product Directory.
drug & metabolites in body fluids
The Orbitrap is an ion trap mass analyzer that consists of two outer electrodes and a central electrode, which enable it to act as both an analyzer and detector. With a QTOF you are already in a range of mass accuracy of about 1-2 ppm and a resolution R = 30000 to 50000. Orbitraps have a mass accuracy in the sub-ppm range and are even better in resolution. Unlike in ion traps and QMFs that require a voltage ramp to detect different m/z's sequentially, in the Orbitrap all m/z's are detected simultaneously. Within the Orbitrap the frequency of ion oscillation in the time domain is measured, with all m/z species measured simultaneously Enabled to detect thousands of semi volatile and non-volatile, high-molecular-weight bio-oil compounds and provided partial information about their structure.
Review Date: 25 Sept 2023 | Thermo Fisher Scientific
Proteomics
Simple to use VERY flexible system. Can do small molecules as well as proteomics
Review Date: 3 Feb 2023 | Thermo Fisher Scientific
Proteomics
Nice operation experience and easy hand-on practice.
Review Date: 10 Mar 2022 | Thermo Fisher Scientific
Phosphoproteomic analysis
The instrumental effectiveness has been shown quite well during the past years’ practical application and test work. The satisfactory analytical results’ reproducibility has also been achieved most of the time. The instrument is relatively easy to control even for beginners and it’s a good choice in terms of performance/cost ratio and maintenance service as well.
Review Date: 16 Apr 2021 | Thermo Fisher Scientific
Pesticides, food, and environmental analysis
Long life, reliable and stable instrument for qualification (MSn) and quantification.
Review Date: 10 Feb 2020 | Thermo Fisher Scientific
Hydrogen deuterium exchange and hydroxyl radical footprinting
This is my first MS instrument and I really liked it. This instrument is so robust and easy to work with. I have used it for hydrogen/deuterium exchange and hydroxyl radical foot-printing experiments. It gives reprodicible results with good signal and minimum sample requirement.
Review Date: 16 Dec 2019 | Thermo Fisher Scientific
Small molecules
Exceptional performance, exceptional training programs by Thermo Scientific.
Review Date: 21 Nov 2019 | Thermo Fisher Scientific
Mass spectrometric analysis of peptides
We use Thermo Fisher LTQ XL system for analysis of small peptides. The MS is bit old but still works well.
Review Date: 26 Mar 2019 | Thermo Fisher Scientific
Analysis of biological macromolecules such as proteins and glycans.
It is one of the powerful mass spctrometers and met most of our requirment for research. The after sale services is also professional and efficient.
Review Date: 26 Mar 2019 | Thermo Fisher Scientific
Proteomics
The instrument enables high quality results with high sensitivity and accuracy in mass spectrometry-based identification of proteins in complex mixtures.
Review Date: 18 Feb 2019 | Thermo Fisher Scientific
Thermo Scientific LTQ Orbitrap XL - The Most Confident Protein Identification
The Thermo Scientific LTQ Orbitrap XL hybrid FTMS (Fourier Transform Mass Spectrometer) supports a wide range of applications from routine compound identification to the most challenging analysis of low level components in complex mixtures. The LTQ Orbitrap XL is based on the fast and highly sensitive Thermo Scientific LTQ XL linear ion trap and the patented Orbitrap* technology. The LTQ Orbitrap XL features a new HCD collision cell for ultimate flexibility in fragmentation experiments for advanced proteomics and small molecule research.
Key features of the Thermo Orbitrap XL include:
Outstanding Mass Accuracy, Resolution, Dynamic Range and Sensitivity
• Featuring the new HCD collision cell for ultimate flexibility in fragmentation experiments for advanced proteomics and small molecule research
• Superior mass accuracy for lower false positive rates (FPRs)
• Parallel acquisition mode for optimized productivity
From Protein ID to Biomarker Discovery with the Thermo LTQ Orbitrap
• Excellent sensitivity and fragmentation efficiency
• Reliable identification and quantitation in one experiment
High quality data from the LTQ Orbitrap XL for reliable de novo sequencing
• Superior mass accuracy and high resolution leading to confident de novo sequencing results
• Multiple collision modes (CID and HCD) for comprehensive structural information