Thermo Scientific LTQ Velos Dual-Pressure Linear Ion Trap
Building on a strong tradition of innovation, the Thermo Scientific LTQ Velos provides significantly enhanced performance for complex sample analyses. The revolutionary dual-pressure ion trap and S-Lens ion optics combine to deliver increased ion transmission along with greater efficiency of ion trapping and fragmentation. The result is the fastest and most sensitive ion trap for virtually all applications. The LTQ Velos™ is…
The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our Product Directory.
Proteomic analysis
A high resolution instrument which helps with the identification of a complex mixture of protein from the proteome of biofilms. The ESI component needs improvement as the needle requires multiple changes within just a few weeks of a run.
Review Date: 6 Mar 2020 | Thermo Fisher Scientific
Protemoics
The mass spectrometer can be easy to use at times but it has mostly been giving the lab some issues in recent months. The mass spec is a little older and being used at a university so it is understandable that it does go down in performance.
Review Date: 26 Mar 2019 | Thermo Fisher Scientific
Analyse food and drug products
The Velos is a workhorse instrument that is easy to use and maintain, and produces good quality data.
Review Date: 6 Mar 2017 | Thermo Fisher Scientific
Building on a strong tradition of innovation, the Thermo Scientific LTQ Velos provides significantly enhanced performance for complex sample analyses.
The revolutionary dual-pressure ion trap and S-Lens ion optics combine to deliver increased ion transmission along with greater efficiency of ion trapping and fragmentation. The result is the fastest and most sensitive ion trap for virtually all applications.
The LTQ Velos™ is the latest evolution in the award winning LTQ family of linear ion trap mass spectrometers. It offers significant improvements in data acquisition rate, sensitivity, and mass resolution.
- S-lens ion optics increase ion transmission and shorten trap fill time, improving instrument sensitivity and data acquisition rate
- More efficient dual-pressure ion trap simultaneously increases scan speed and mass resolution
- Predictive Automatic Gain Control reduce cycle times, yielding improved data acquisition rates
- Improved sensitivity and mass resolution increase confidence in identification of low-level analytes
- Increased performances enables simultaneous identification, structural elucidation, and quantification of complex samples
- Upgradeable to the ultra-high resolution and outstanding mass accuracy of OrbitrapTM technology