Products & ReviewSeparations

ZORBAX Eclipse AAA

The ZORBAX Eclipse AAA high efficiency HPLC column rapidly separates amino acids following an updated and improved protocol. Total analysis from injection to injection can be achieved in as little as 14 min (10 min analysis time) on the short, 7.5 cm column and 24 min (16 min analysis time) on the 15 cm column length.Exceptional sensitivity (5 - 50 pmol with DAD, FLD) and reliability are achieved using both OPA and FMOC deriv…

Agilent Technologies

The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our  Product Directory.

Average Rating 4.1

|10Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Average Rating 3.0

Excellent compared to the other columns, especially the separation efficiencies, which are much higher than that of the other ones.

Review Date: 7 Aug 2013 | Agilent Technologies

Average Rating 4.0

These columns are very reliable and very good. I like to work with these columns in my work. Easy to use and easily available. Good price and design.

Review Date: 7 Aug 2013 | Agilent Technologies

Average Rating 4.0

Application Area:

ENVIRONMENTAL ANALYSES

This column is suitable for the real analyses of the environmental samples. But, we really need a wide sized column for the preparation of the samples up to 100 mL. Also, for the biological samples, shorter column is required. The most important point, the price should be decreased.

Review Date: 4 Jun 2013 | Agilent Technologies

Average Rating 5.0

Application Area:

Impurity analysis

Zorbax columns are excellent performing columns. It is very stable and reproducible. Different selectivity observed by using C18, PHE and Biphenyl columns.

Review Date: 3 Jun 2013 | Agilent Technologies

Average Rating 4.3

Application Area:

pesticides

Agilent support is great. They conducted a seminar at our location on porous particles. Columns are a bit pricier.

Review Date: 3 Jun 2013 | Agilent Technologies

Average Rating 5.0

The Zorbax Eclipse columns are versatile and simple to use. They allow for high throughput. Highly Recommended!

Review Date: 28 May 2013 | Agilent Technologies

Average Rating 3.7

Application Area:

analysis molecules

I used this column when I need to analyse some molecules, for example, glyphosate, tetracycline, like antibiotics, and such as pesticide drugs. I feel like that this is an amazing HPLC column I have ever experienced.

Review Date: 22 May 2013 | Agilent Technologies

Average Rating 3.3

Application Area:

Natural Product

Great column

Review Date: 21 Feb 2012 | Agilent Technologies

Average Rating 4.3

Application Area:

Environmental

We have been using a 250 mm x 3.2 mm Stablebond -18 for several of our environmental analysis. This column has with excellent retention and peak shape for acid, neutral and basic compounds.

Review Date: 16 Feb 2012 | Agilent Technologies

Average Rating 4.7

The best analytical column for NDA- derivatives separation.

Review Date: 19 Sept 2011 | Agilent Technologies

The ZORBAX Eclipse AAA high efficiency HPLC column rapidly separates amino acids following an updated and improved protocol.

Total analysis from injection to injection can be achieved in as little as 14 min (10 min analysis time) on the short, 7.5 cm column and 24 min (16 min analysis time) on the 15 cm column length.

Exceptional sensitivity (5 - 50 pmol with DAD, FLD) and reliability are achieved using both OPA and FMOC derivitization chemistries in one fully automated procedure using the Agilent 1100 HPLC instrument. Eclipse AAA columns are used for high resolution rapid analysis of 24 amino acids. The Eclipse AAA uses well known OPA and FMOC derivatization techniques.


ZORBAX Eclipse AAA Features:

  • High resolution and rapid analysis of 24 amino acids.
  • Tested for amino acid analysis.
  • Uses well-known OPA and FMOC precolumn derivatization chemistry.
  • Easily automated using a detailed online, derivatization protocol available for use with Agilent 1100/1200 autosampler.

Column Characteristics:

  • Pore Size: 3.5, 5.0 µm
  • Length: 75, 150 mm
  • ID: 4.6 mm

Product Overview

Links