LenS3 MALS and MALS-V Multi-Angle Light Scattering Detector Series

Tosoh BioscienceAvailable: Worldwide

The LenS3 MALS detector offers a revolutionary approach for the measurement of molecular weight (MW) and radius of gyration (Rg) of synthetic polymers, polysaccharides, proteins, and biopolymers. A novel optical design, a unique cell-block assembly, and a new calculation methodology make the LenS3 MALS detector the first groundbreaking innovation in the light scattering technology arena in decades! The new member of the LenS3…

Request Pricing
Tosoh Bioscience

Receive your quote directly from the manufacturer.

Average Rating 3.3

|1Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Get a In House Demo when buying a MALS

 

Average Rating 3.3

Application Area:

SEC of Proteins for molecular weight

Initially, this detector worked well and did all the analysis we would want for characterizing protein Mw, Mn). After 3 months it failed and had to be sent back to the manufacturer. I am waiting for a diagnosis of what is wrong. It takes an overnight equilibration to stabilize the detector and it uses a pre-filter (0.2 microns) going into the detector and a post filter (0.1 microns). The filter backpressure goes up and stops the analysis after 24 hours (sometimes earlier). The instrument was initially installed (validated) with only a 0.45-micron mobile phase. I was told by one company tech rep to filter using 0.05-micron filter). I never heard of anyone doing this for any other analysis, such as LC-MS. This detector is about 1/2 the cost of the next rival MALS manufacturer. For anyone thinking about getting one, it would be wise to have a demo in your lab and know what it takes to get this going. I have to say the other manufacturers were very slow to demo their equipment. TOSOS was very responsive.

Review Date: 15 Nov 2021 | Tosoh Bioscience

The LenS3 MALS detector offers a revolutionary approach for the measurement of molecular weight (MW) and radius of gyration (Rg) of synthetic polymers, polysaccharides, proteins, and biopolymers. A novel optical design, a unique cell-block assembly, and a new calculation methodology make the LenS3 MALS detector the first groundbreaking innovation in the light scattering technology arena in decades! The new member of the LenS3 family, the LenS3 MALS-V dual detector, is the first integrated light scattering and viscometry dual detector. Combined with the EcoSEC Elite GPC system and TSKgel columns, it offers a complete, cost-effective, high-performance approach for triple detection GPC.

Featuring a patent pending cell geometry and a lower wavelength laser (at 514 nm), the LenS3 MALS detector allows direct measurement of molecular weight and provides best-in-class sensitivity. In addition, with an improved normalization process and a new method for utilizing the angular dependence, the determination of radius of gyration of smaller macromolecules below 10 nm in gyration size, Rg, is now possible for the first time in history!

The LenS3 MALS and LenS3 MALS-V detectors are driven by SECview software, capable of GPC system/hardware control, multi-channel data acquisition, data processing and analysis. Totally focused around enhancing the user-interface experience, SECview is a welcoming fresh perspective that streamlines the complex calculations required by the advanced detectors and is the only GPC/SEC data processing module today that performs analysis of sample-of-interest using multiple calibration methods simultaneously.