CrossLab Enterprise Services
Agilent TechnologiesImprove Productivity across your Laboratories with CrossLab Enterprise Services
Improve Productivity across your Laboratories with CrossLab Enterprise Services
With Remote Advisor, networked compatible instruments can provide health, status, service assist and report delivery information from common instrument output files (for example, log files) while bypassing confidential, scientific data. CrossLab Remote Advisor has the ability to dramatically increase laboratory productivity by optimizing instrument availability and uptime.
Agilent now treats each premium 11mm inlet septa to eliminate sticking in the GC inlet. With our premium non-stick septa, you'll never have to scrape bits of septum out of your inlet. Agilent's premium septa also have a recess on the injection side, to guide the syringe needle to the same point with every injection.
Economy Indicating Moisture Removal Traps Agilent Indicating Moisture Traps are designed to remove water, oil, and organics from gases employed in, but not limited to, gas chromatography. Refillable moisture traps are constructed from Lexan brand polycarbonate tubing. Lightweight, chemically resistant and of superior strength when compared to traps manufactured from acrylic. Agilent Indicating Moisture Traps have become the…
Agilents Precision Gas Flow Meter is the ultimate gas flowmeter for chromatography applications. This handheld flowmeter incorporates industry leading performance and features in a highly accurate and reliable package. The inherent stability of the rugged, solid state components allows us to provide the longest calibration interval on the market, all traceable to NIST standards.
The Renewable Gas Purification System from Agilent not only traps large quantities of contaminants and lasts a long time, but it is also recyclable.
Frustrated with leaky, hard to use press-fit connectors? Now anyone in your lab can easily connect guard columns or retention gaps to GC columns by using Agilent Ultimate Union kits.
Extra large gas purifiers (750 cc) are ideal for bulk purification applications or where several instruments are plumbed from a single gas source. They provide a low cost alternative to UHP grade gases. We construct each trap from one piece of heavy walled aluminum tube to eliminate potential leaks due to faulty welds. The moisture and hydrocarbon models can be refilled. The big oxygen traps must be replaced, but we offer indi…
GC/MS Test and Performance Samples Agilent J&W GC Column Test StandardsLC and LC/MS Standards GPC/SEC and GFC Calibration Standards Amino Acids Standards and Reagents CE Standards and Reagents ICP-MS Standards UV-Vis Standards and Reagents Application Specific Standards Residual Solvent Standards SampliQ QuEChERS Standards GC Instrument Evaluation Analyzer Kit Standards GC Instrument Installation and Calibration Standards
Agilent's Direct Connect Liners provide maximum recovery and minimal decomposition of active compounds for methods requiring splitless injection, such as EPA 8270.
The ion source operates by electron ionization (EI) or chemical ionization (CI). The sample enters the ion source from the GC/MSD interface. Electrons emitted by a filament enter the ionization chamber, guided by a magnetic field. The high-energy electrons interact with the sample molecules, ionizing and fragmenting them. The positive voltage on the repeller pushes the positive ions into the lens stack, where they pass throug…
Agilent handheld electronic crimpers deliver tight, reproducible seals every time. Slim, adjustable steel jaws fit around closely spaced vials, enabling you to crimp vials directly in vial trays. Our electronic decappers remove caps quickly, and are designed for labs that recycle or reuse vials.
Agilent’s new Flip Top Inlet Sealing System is a device designed to allow the user to safely and reliably change an inlet liner in as little as 30 seconds without tools in a consistent leak-free manner.
Agilent’s General Purpose Septa are made from an enhanced injection-molded silicone rubber material.
Agilent offers a comprehensive selection of ferrules made of different materials and configurations for a leak-free connection between the column and injector. Graphite ferrules can withstand temperatures as high as 450 °C.
Employing the easy release clamping design, these fittings offer a quick and simple solution to vacuum system design and assembly. Bakeable to 150º C when using Viton O-Rings, these fittings are ideal for roughing or high vacuum applications.
HTS and HTC PAL Syringes To better serve Agilent instrument users who choose CTC Analytics autosamplers for high-throughput and flexible sample introduction, Agilent has partnered with CTC to provide a fully integrated system, including CTC-approved x-type syringes designed specifically for HTS and HTC PAL.
HTS and HTC PAL Valve Supplies To better serve Agilent instrument users who choose CTC Analytics autosamplers for high-throughput and flexible sample introduction, Agilent has partnered with CTC to provide a fully integrated system, including CTC-approved valve supplies.Whether your HTS or HTC PAL autosampler uses the Agilent proprietary Rheodyne high-pressure 600-bar injection valve or Valco Cheminert injection valves, Agil…
Our Hydrocarbon Traps allow you to refill your trap and remove extremely low levels of hydrocarbons. Big Hydrocarbon Traps (BHT) are ideal for bulk purification applications or where several instruments are plumbed from a single gas source. Hydrocarbon Removal S-Traps are filled with 40/60 mesh activated charcoal and can be reconditioned. Capillary Grade Hydrocarbon Traps (HT3) feature extremely high surface area, are coconu…
Our hydrocarbon/moisture traps offer you flexibility -- refill your trap and remove extremely low levels of both moisture and hydrocarbons.
Agilent's Indicating Oxygen Trap is designed to be used in conjunction with any of our high capacity, non-indicating oxygen traps. When properly installed downstream from the non-indicating trap, the Indicating Oxygen Trap provides a visual indication of oxygen breakthrough before contamination reaches sensitive system components. Unlike adsorbent materials utilized in competitive products, our indicating media can be exposed…
Capture contaminants released by split injection systems Split vent traps capture contaminants released by split injection systems. Remember to replace the split vent cartridges every six months.An internal split vent trap is factory installed to ensure the split vent line does not clog, creating system errors or expensive repairs. Replacement cartridges are available. The optional external trap provides additional protecti…
Agilent now treats each premium 11mm inlet septa to eliminate sticking in the GC inlet. With our premium non-stick septa, you'll never have to scrape bits of septum out of your inlet. Agilent's premium septa also have a recess on the injection side, to guide the syringe needle to the same point with every injection.
Bleed and Temperature Optimized Non-Stick Septa (BTO) Agilent now treats each premium 11 mm inlet septa to eliminate sticking in the GC inlet. With our premium non-stick septa, you'll never have to scrape bits of septum out of your inlet. Agilent's premium septa also have a recess on the injection side, to guide the syringe needle to the same point with every injection.