Cannabis Testing Products & Reviews

Cannabis testing is a process that evaluates the safety, potency, and quality of cannabis products for medical and recreational use. Through rigorous analysis, cannabis testing laboratories assess factors such as cannabinoid content, terpene profiles, and levels of contaminants like pesticides and heavy metals. By ensuring compliance with regulatory standards and consumer safety, cannabis testing plays a crucial role in promoting transparency and confidence in the burgeoning cannabis industry. Explore how cannabis testing laboratories contribute to delivering reliable and high-quality cannabis products to consumers worldwide.

Product Filter

Cannabis Testing
Browse by Techniques
Explore by Company

Ratings

Search

DASH™ -HTS Fast LC/MS Columns

Thermo Fisher Scientific

o   The benchmark in based deactivated silica columnso   Sharp peaks and improved symmetry for basic compoundso   Value and performance from a globally referenced column Product detail: DASH columns are packed to the same high standards as our analytical columns, and offer superioir chromatographic resolution in a design that eliminates the need for endfittings and wrenches during column change over. This makes column inst…

4.0/5.0
|3 Reviews

Fluophase RP/PFP Columns

Thermo Fisher Scientific

Fluophase RP Columns o   A range of perfluorinated phases for alternative selectivityo   Extra retention and selectivity for halogenated compoundso   Select from 100Å and 300Å pore sizes Product detail:For alternative selectivity to traditional alkyl phases, we recommend you try the perfluorinated phases of Fluophase columns. The stationary phase of Fluophase RP contains a perfluorinated C6 chain, where every hydrogen atom on…

4.0/5.0
|2 Reviews

Hypersil 100 C8/C18 columns

Thermo Fisher Scientific

Hypersil 100 C8 Columns Compared to other classical materials, Hypersil 100 has a smaller pore diameter of only 100Å, which creates a higher specific surface area that can be advantageous where longer retention times are needed, such as chromatography of polar compounds. Product detail: Compared to other classical materials, Hypersil 100 has a smaller pore diameter of only 100Å, which creates a higher specific surface area…

4.2/5.0
|2 Reviews

HPLC Guard Cartridges

Thermo Fisher Scientific

The UNIGUARD drop-in cartridge fits both our guard systems: the stand alone UNIGUARD and the Direct Connection UNIGUARD. Product detail: We recommend all analytical columns are protected by a guard cartridge, which is replaced on a regular basis. The ID of the analytical column determines the correct ID for the guard cartridge. We offer 10x1.0, 10x2.1, 10x3.0, 10x4.0 (for use with both 4.0 and 4.6mm ID analytical columns) i…

4.4/5.0
|9 Reviews

PRP-X600 Anion HPLC Columns

Hamilton Company

PRP-X600 is a superficially porous weak-base anion exchange support that separates DNA oligomers according to negative charge. PRP-X600 provides the following benefits:Fast SeparationThe unique porosity provides fast separation with better sample capacity than non-porous supports.StabilityThe polymeric PRP-X600 support is stable to a variety of mobile phases. From inorganic buffer solvent to high concentration organic modifier…

4.0/5.0
|1 Review

Model 1020A TOC Analyzer with WinTOC

Xylem

Analyze the most challenging real-world samples with complete confidence using the Model 1020A TOC Analyzer. Its advanced catalyst technology and approved combustion method is the best analytical technique for accurate and reproducible measurement of dirty, salty, or particulate-laden samples. With its easy operation, reliability, space-saving design, wide linear range, and outstanding accuracy, the Model 1020A delivers unmatc…

4.0/5.0
|2 Reviews

MAT253

Thermo Fisher Scientific

The MAT 253 stable isotope ratio mass spectrometer system delivers the highest sensitivity and the highest precision for the determination of isotope ratios. The MAT 253 provides a flexible and open platform for the connection of inlet systems and preparation devices. The ISODAT NT isotope data systems ensures easy set up, tuning and fully automatic operation.

4.0/5.0
|1 Review


ND-8000 8-Sample UV-Vis Spectrophotometer

Thermo Fisher Scientific

The ND-8000 8-Sample UV-Vis Spectrophotometer measures 1 ul samples, up to 8 at a time. Like the popular ND-1000, the ND-8000 utilizes a patented sample retention system that eliminates the need for cuvettes and capillaries and allows for a complete measurement cycle (analyses of 8 samples and cleaning) in 30 seconds or less. In addition, the high absorbance capability eliminates the need for dilutions in most cases. For loadi…

4.4/5.0
|6 Reviews

HP-Chiral B capillary GC column

Agilent Technologies

Agilent J&W HP-Chiral ß has a chiral stationary phase based on permethylated beta-cyclodextrin, which has very broad applications for resolving volatile optical isomers. Beta-cyclodextrin is dispersed in a phenyl-based polymer. This polymer provides low bleed and will not interfere with nitrogen-specific detectors such as the nitrogen phosphorus (NPD) detector, allowing optimized sensitivity for chiral compounds containing ni…

4.2/5.0
|6 Reviews