Cannabis Testing Products & Reviews

25

Cannabis testing is a process that evaluates the safety, potency, and quality of cannabis products for medical and recreational use. Through rigorous analysis, cannabis testing laboratories assess factors such as cannabinoid content, terpene profiles, and levels of contaminants like pesticides and heavy metals. By ensuring compliance with regulatory standards and consumer safety, cannabis testing plays a crucial role in promoting transparency and confidence in the burgeoning cannabis industry. Explore how cannabis testing laboratories contribute to delivering reliable and high-quality cannabis products to consumers worldwide.

Product Filter

Cannabis Testing
Browse by Techniques
Explore by Company

Ratings

Search

Selected Filters:

3M™ Empore™ C18-SD Standard Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ MPC-SD Standard Well Plate

3M Bioanalytical

This mixed phase chemistry, in which two primary modes of attraction are present, allows for a more efficient and selective extraction compared to traditional reversed phase techniques.  Neutral and ionized analytes can be simultaneously extracted from a complex mixture and eluted as separate fractions.  A mixed phase sorbent offers the following advantages: Eluting acidic and neutral analytes separately from basic analy…

0.0/5.0
|0 Reviews



3M™ Empore™ C8-SD Deep Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ C18-SD Deep Well Plate

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ MPC-SD Deep Well Plate

3M Bioanalytical

This mixed phase chemistry, in which two primary modes of attraction are present, allows for a more efficient and selective extraction compared to traditional reversed phase techniques.  Neutral and ionized analytes can be simultaneously extracted from a complex mixture and eluted as separate fractions. A mixed phase sorbent offers the following advantages: Eluting acidic and neutral analytes separately from basic analyt…

0.0/5.0
|0 Reviews



3M™ Empore™ C8-HD 1ml Cartridge

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ C8-SD 1ml Cartridge

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ C18-SD 1ml Cartridge

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ C8-SD 3ml Cartridge

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ C18-SD 3ml Cartridge

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews


3M™ Empore™ C18-SD 6ml Cartridge

3M Bioanalytical

Functional groups, such as octyl (C8) and octadecyl (C18), can be bonded to the silica surface to provide non polar interactions.  Each of these sorbents exhibits unique properties of retention and selectivity for a particular analyte.  The choice of which sorbent is best for a particular method will be influenced by the percent recovery of analyte from the sample matrix and the cleanliness of the resulting chromatography.

0.0/5.0
|0 Reviews

3M™ Empore™ SDB-XC 6ml Cartridge

3M Bioanalytical

SDB-XC is a poly(styrenedivinylbenzene) copolymer used as a reversed phase sorbent for solid phase extraction.  SDB-XC is not bonded to silica but is a 100% copolymeric particle that is spherical, porous and cross-linked.  It does not exhibit the secondary cationic (silanol) interactions and pH limitations common to bonded silica sorbents, so it offers more predictable and reproducible reversed phase interaction.

0.0/5.0
|0 Reviews

Empore™ Accessory Vacuum Manifold for 96 Well Plates

3M Bioanalytical

The Empore™ High Performance Extraction Disk Plate differs in design from plates offered by other manufacturers and requires a specific vacuum manifold.  Manifolds supplied by different plate manufacturers are specific to the design of their plates and cannot generally be used with plates from other manufacturers.  In some cases, the use of spacers to raise/lower the height of a collection device inside the manifold may overco…

0.0/5.0
|0 Reviews


Empore™ Accessory Sealing Tape Pad for 96 Well Plates

3M Bioanalytical

EmporeTM Tape Pads are intended for sealing unused portions of a 96-well solid phase extraction plate during vacuum processing to enable vacuum to be uniformly applied to each well being used.  Use a clean sheet each time for maximum sealing ability.  Note: these tape sheets are not intended for sealing collection plates prior to sample injection because the adhesive may clog the injection needle.

0.0/5.0
|0 Reviews

Empore™ Accessory Filter Aid 400

3M Bioanalytical

Empore Filter Aid 400 has been shown to improve flow rates and recoveries for separation and filtration of water samples containing suspended solids.  When placed on top of the Empore™ Extraction Disk at a depth of about 1 cm, Empore™ Filter Aid 400 acts as depth filter to inhibit the migration of suspended solids to the surface of the disk.  This reduces extraction time and improves rates and recovery of analytes.

0.0/5.0
|0 Reviews

Bio-Monolith

Agilent Technologies

Agilent Bio-Monolith HPLC columns provide high resolution and rapid separations of antibodies (IgG, IgM), plasmid DNA, viruses, phages and other macro biomolecules. The product family offers strong cation exchange, strong and weak anion exchange, and Protein A phases.

0.0/5.0
|0 Reviews

HySphere™ C8 EC-SE

Spark System Solutions B.V.

Spark has introduced the second edition of HySphere™ C8 End-Capped cartridges. We have selected a new perfect Spherical sorbent material with a narrow particle size distribution. This will create less back pressure during operation and allows you to run higher flow rates compared to our current HySphere™ C8 (EC). The new cartridge has the same excellent characteristics such as high extraction capacity and selectivity

0.0/5.0
|0 Reviews

Corning® 150 mL Bottle Top Vacuum Filter, 0.45 µm Pore 13.6cm² CA Membrane, Fits 33 mm Diameter Necks, Sterile, 48/Case

Corning Life Sciences

Fits plastic or glass media bottles with 33mm neck sizes. Cellulose acetate (CA) membranes provide fast flow rates and low protein binding and are good for filtering cell culture media. Angled hose connector simplifies vacuum line attachment. Individually packaged, sterile and certified nonpyrogenic. Each system has the membrane material and pore size printed on the unit and is color-coded by membrane type for easy produ…

0.0/5.0
|0 Reviews

Pulsed discharge detectors Model D-2

VICI AG International

VICI introduces the GC detector where the PDD (pulsed discharge detector) utilizes a stable, low-powered, pulsed DC discharge in helium as the ionization source. The D-2 is a dual mode, universal detector system which can be retrofitted to your older GC. The D-2-I is a helium photoionization detector, optimized for trace level work with packed columns. The stand-alone systems include detector, controller, electrometer, helium…

0.0/5.0
|0 Reviews