SLIPFREE Column Connectors
Thermo Fisher ScientificSingle & double end fittings in stainless steel & PEEK collared connectors
Environmental monitoring and testing assess the quality of our air, water, soil, and overall ecosystems. Using advanced technologies and analytical methods, environmental scientists collect and analyze samples to measure levels of pollutants, contaminants, and other factors impacting environmental health. By monitoring changes over time and identifying potential risks to human health, this field plays a vital role in informing policy decisions and implementing effective mitigation strategies. Explore how environmental monitoring and testing contribute to safeguarding our planet's well-being and promoting sustainable development.
Single & double end fittings in stainless steel & PEEK collared connectors
HyperGEL columns are packed with porous polymeric beads with a precise pore size distribution so that solutes are accurately separated according to molecular size.High efficiency HyperGEL columns provide a minimum of 50,000 plates/metre for 5µm particle size. The columns are available for aqueous (HyperGEL AP) or organic (HyperGEL OP) separations.HyperGEL OP columns are offered in 7 pore sizes and 2 particle sizes to test mole…
Get maximum loading and efficiency from your preparative columns. Achieve high loading with Thermo Electron phases and column sizes up to 50mm ID and 250mm length. Our column packing and silica expertise ensures our preparative columns achieve optimum efficiency and lifetimes.Our BETASIL™ and Hypersil™ 100 phases are ideal for preparative separations. We recommend the separation is proven using an analytical scale column packe…
o Excellent retention and alternative selectivity for polar compoundso Completely stable under 100% aqueous conditionso Ideal for LC/MS applications Product detail: AQUASIL C18 columns provide more retention for difficult-to-retain polar compounds due to a unique hydrophillic end-capping. The combination of a moderate coverage C18 group and an additional polar group gives new selectivity compared to a traditional C18.…
HyPURITY ADVANCE Columns - offer exceptional chromatographic performance and is ideal for high throughoput laboratories with complex and variable sample types. Product detail: HyPURITY ADVANCE contains a polar amide group embedded within a C8 chain, and is fully endcapped. The columns are based on our metal free HyPURITY silica and, compared to other phases, produces a competely new selectivity. A polar functiona…
Hypersil BDS C18 Columnso Sharp peaks and improved symmetry for basic compoundso Value and performance from a globally referenced columno Long column lifetimes with excellent column-to-column and batch-to-batch reproduciblity Product detail:Hypersil BDS C18 receives a special base deactivation treatment during silica material manufacture to reduce silanophilic activity. Hypersil BDS C18 is endcapped and suitable for chro…
o Based on ultra pure 190 Å pore size silica for analysis of small molecules to proteinso Extensive quality control tests to ensure the ultimate in reproducibility and performanceo Unbeatable peak shapes for all sample typeso Select from five phases for a wide range of selectivity options Product detail: HyPURITY C18 columns are based on the latest in silica technology - HyPURITY silica, which has less than 10ppm total m…
To obtain precise information about the structure of synthetic peptides and proteins, it is imperative to achieve good separation (see illustration).Hypersil Amino acid columns have been developed for this purpose with excellent reproducibility and the highest reproducibility using high grade 5µm particle size silica with a high surface area. Achieve resolution of complex sequences of amino acids with sharp peak shapes.Hypersi…
High efficiency capillaries for high performance, sensitive separations 500, 320, 180, 100 & 75µm ID capillaries Availabe in a wide range of Thermo phases Rugged sleeved design for robustness 180µm ID flexible KAPPA for FinniganTM ProteomeX™ Workstation Product detail: Capillary and nanobore columns are ideal for applications which require high sensitivity. However, in order to take full benefit of the improvement i…
The next generation in MALDI CID MS/MS A TOF-TOF mass spectrometer with high energy MS/MS The AXIMA-TOF2 is one of the most powerful tools in mass spectrometry, delivering information-rich spectra with greater sensitivity and higher confidence in identification. It is an extremely versatile and powerful TOF-TOF system, integrating workflows for a diverse range of analytical needs. Key benefits and features Delivers the hig…
Mounts up to Six Detectors and Five Injectors Ambient to 400oC Temperature Programmable Column Oven Dimensions: 19" wide x 13.5" high x 14.5" deep Implement virtually any EPA or ASTM method The Model 8610C Gas Chromatograph is our most versatile and popular model. While it is very compact next to comparable laboratory GCs from other manufacturers, it is large enough and flexible enough to perform an amazing variety o…
Ultra-fast – 100 scans/second Process rugged – industrial encoder 1375 to 2750 nm spectral range Aspectrics MultiComponent 2750 Process Analyzer is a breakthrough for Near Infrared analysis. Built on Aspectrics patented Encoded Photometric Near Infrared (EP-NIR) technology, the Aspectrics MultiComponent 2750 Analyzer covers an unprecedented spectral range of 1375 to 2750 nm. Traditional NIR systems typically stop at 21…
Run assays up to 5 times faster than a conventional HPLC. Increase mass spec sample throughput by a factor of 5. Eliminate dead time in your analysis and cut solvent usage by 99 percent. Achieve all this and more with the ExpressLC-100 system. TheExpressLC-100 system is a single-channel HPLC with binary solvent delivery, high pressure gradient mixing, variable volume injection, UV absorbance detection, and PC-based instrument…
High Throughput SonicationFeatures: Stand-alone instrument 96, 384, and 1536 interchangeable disposable pinned lid technology Plate shuttle allows for direct integration with pick & place robotics. Variable power settings between 1 and 1150 watts. Variable sonication time intervals from 0.1 to 20 seconds.
The SmartLab is the most novel high-resolution diffractometer available today. Perhaps its most novel feature is the SmartLab Guidance software, which provides the user with an intelligent interface that guides you through the intricacies of each experiment. It is like having an expert standing by your side. The system incorporates a high resolution θ/θ closed loop goniometer drive system, cross beam optics (CBO), an in-plane…
The AC600 sets the standard for future calorimetry instruments. Its semi-automated operation combined with the use of thermodynamic TruSpeed™ obtains a rapid analysis of calorific content and increased instrument throughput without sacrificing accuracy or instrument precision. A new, ergonomically designed, lightweight combustion vessel assures ease of operation while greatly reducing operator strain.
Mass Frontier 4.0 provides you with the tools required to transform mass spectral data into results – fast! The new Mass Frontier excels at predictive fragmentation and data management. Mass Frontier provides a mechanistic understanding of fragmentation schemes using proprietary mass spectral interpretation algorithms. In addition, relationships within datasets can be explored using various types of classification such as PCA,…
Xcalibur™ software is a flexible Windows® based data system that provides instrument control and data analysis for the entire family of Thermo Electron mass spectrometers and related instruments. Xcalibur's wide range of functionality and ability to integrate third-party control provides the tools to perform a wide range of applications. Several specialized software modules have been designed to work with Xcalibur to meet…
The LTQ XL™ extends the legendary MSn performance of the LTQ™, incorporating more techniques to generate structural information through Thermo Scientific’s innovations in ion trap technology. Thermo Scientific's LTQ XL is the only mass spectrometer that offers multiple dissociation techniques, PQD, ETD and CID. Pulsed Q Collision Induced Dissociation (PQD) is a patented technique that eliminates the low mass cut-off concern in…
Peptide maps generated by RP-HPLC provide valuable information about protein structure, stability, and purity. To be effective, the RP-HPLC column must be able to resolve a high percentage of the peptides in the sample. The more peptides, the better the information. Discovery BIO Wide Pore C18 gives unsurpassed RP-HPLC resolution of peptide maps from enzymatic digests. The improvements in silica and bonded-phase chemistry we h…
Easily separate N-1 failure sequences from target oligo with > 90% purities
SecurityGuard offers a convenient and economical way to extend HPLC column lifetimes. Did you know a common cause of high backpressure, split peaks, broad peaks, baseline noise, baseline drift and loss of resolution is contaminants? The fact is all mobile phases contain some chemical contaminants or microparticulates, from the sample, solvent, or wear on the polymeric seals of the pump or injector. These contaminants can…
Accessories and Consumables for FTIR and Dispersive IR instruments to fit virtually any manufacturer's instrument. But before you choose just any accessory check out the MIRacle and GladiATR. Not only the highest throughput single bounce diamond ATRs, but with robust Hastelloy top plates make for maximum durability and acid resistance. With an optional digital 'true force' gauge. These are truly remarkable accessories. Wi…
LabSolutions is Shimadzu´s software series for chromatography (GC, GCMS, LC, LCMS). The unified graphical interface makes it easy to work with Shimadzu chromatography products. The GCsolution and GCMSsolution is the perfect partner for the Shimadzu GC and GCMS product range. The GCsolution controls the GC-2010 and GC-2014 (from Ver. 2.3) as well as the previous models GC-14 and GC-17. The GCMSsolution Ver. 2 controls the GCMS-…
TOC-VWP TOC-V wet type series have a high-sensitivity NDIR which achieves ultrahigh sensitivity measurements. Features: Automatic setting of optimal measurement conditions: When creating the calibration curve, the optimal measurement conditions are displayed when the standard solution concentration is set. Detailed calibration curve information can easily be referenced when setting the measurement conditions. Au…