Environmental Products & Reviews

Environmental monitoring and testing assess the quality of our air, water, soil, and overall ecosystems. Using advanced technologies and analytical methods, environmental scientists collect and analyze samples to measure levels of pollutants, contaminants, and other factors impacting environmental health. By monitoring changes over time and identifying potential risks to human health, this field plays a vital role in informing policy decisions and implementing effective mitigation strategies. Explore how environmental monitoring and testing contribute to safeguarding our planet's well-being and promoting sustainable development.

Product Filter

Environmental
Browse by Techniques
Explore by Company

Ratings

Search

Syringes for Valco, Cheminert, and Rheodyne® HPLC injectors

VICI AG International

Syringes used to fill a loop on a sample injection valve have blunt, smooth ends. The end of the needle must contact the bottom of the valve’s fitting detail uniformly and seal on the outside of the tip to deliver sample with any repeatability. All VICI Precision Sampling syringes for valve injections have smooth, burr-free ends that fit the valve fitting details perfectly. The standard HPLC syringe is our basic C-160 with a 2…

0.0/5.0
|0 Reviews

Hollow plunger syringes

VICI AG International

Hollow, flow-through plunger with integrated 3-way valve designed for liquid and gases, with a push button on/off valve at the front end. The new Precision Sampling hollow plunger syringe with two integrated valves opens a whole new world of application possibilities: Dispense a viscous sample more easily by introducing it into the rear of the syringe instead of drawing it up through the needle. Eliminate sample-to-sample cros…

0.0/5.0
|0 Reviews

Dual Layer PEEK tubing

VICI AG International

The Dual Layer PEEK tubing eliminates any concern that a critical sample stream could be contaminated by pigments used to color code the tubing.  The pigmented layer surrounds a separate but integrally-bonded inner layer of natural PEEK. The 1/16" OD tubing is available in standard sizes, or in OEM quantities with any ID you specify, from .002" to .030". The ID tolerance of ±.001" is equivalent to or better than that of tubing…

0.0/5.0
|0 Reviews

Pre-miR™ miRNA Precursor Molecules and Libraries

Thermo Fisher Scientific

Ambion Pre-miR™ miRNA Precursor Molecules are small, chemically-modified double-stranded RNA molecules designed to mimic endogenous mature miRNA molecules. These ready-to-use miRNA mimics, which are similar to but not identical to siRNAs, can be introduced into cells using transfection or electroporation parameters identical to those used for siRNAs and enable detailed study of miRNA biological effects via gain-of-function e…

0.0/5.0
|0 Reviews

Baroxymeter

TCS Biosciences Ltd

The Baroxymeter is a portable respirometer designed for Direct Toxicity Assessment (DTA) of waste water. DTA takes a risk-based approach to water quality analysis, using effects in biological systems as a basis for assessing likely harm to an ecosystem in water receiving effluent discharges. With DTA, an integrated assessment is made of the impact of complex mixtures of pollutants, which can usually only be partially character…

0.0/5.0
|0 Reviews

SimGlycan Software

Thermo Fisher Scientific

SimGlycan™ Software (a product of PREMIER Biosoft International) predicts the structure of a glycan from the MS/MS data acquired by AB SCIEX mass spectrometers. It facilitates the study of glycosylation and post translational modifications. The software works directly with *.t2d and *.wiff data generated from AB SCIEX instruments, including the 4800 Plus MALDI TOF/TOF™ Analyzer, 4000 QTRAP® System, and QSTAR® Elite System. * M…

0.0/5.0
|0 Reviews

LC Tech Elufix™

ARC Sciences

The Advantages at a Glance Ready to use columns No more laborious cleaning of Glass Columns Easy handling Reduced Costs- the more samples the more cost effective Certified Columns Excellent Performance The determination of the hydrocarbon oil index in surface, industrial and process water in compliance with EN ISO 9377-2 (H53) is daily routine in many laboratories. Using intelligent sample preparation, time and costs for the a…

0.0/5.0
|0 Reviews

ZORBAX 80Å Extend-C18 (USP L1)

Agilent Technologies

"Extend-C18 columns incorporate a unique patented bidentate silane, combined with a double-endcapping process that protects the silica from dissolution at high pH - up to pH 11.5. Columns are best applied for separations of compounds that are either (1) basic and have little or no retention at low or intermediate pHs, (2) more stable or more soluble at high pH, or (3) basic and show poor peak shape at low or intermediate pH.…

0.0/5.0
|0 Reviews

Thermal Desorption

Agilent Technologies

Thermal desorption (TD) combines sample preparation, extraction, and injection into a single automated process for the analysis of volatile and semi-volatile organic compounds (VOC and SVOC).

0.0/5.0
|0 Reviews

ELSD- Model 1400

Kromatek

Designed for Rapid Resolution and Ultra Performance LC Systems • Communicates with ChemStation via an exclusive SofTA Driver. • Superior HPLC Detection to Replace or Complement your Current Detection. • Sensitive Detection for a Wide Variety of Chemical Classes and Structures. • Easy to Use, Fast Start-up, No Consumable Parts, Low Cost of Operation. • Precise Vapor Phase Control with SofTA Exclusive Thermo-Split™ Technology. •…

0.0/5.0
|0 Reviews