Drug discovery > Pre-Clinical Development Products & Reviews
Products, services, reviews and techniques used in lead molecule delivery, formulation and toxicology, using assays and animal models.
Selected Filters:
MagNA Pure LC Barcode Reader Quick Scan 1000
The MagNA Pure LC Barcode Reader Quick Scan 1000 enables sample identification and tracking during the entire MagNA Pure LC purification run. It reads the bar code on primary tubes, as well as bar codes generated by the MagNA Pure LC Barcode Printer TLP 2844 (Cat. No. 03 576 094 001) for the MagNA Pure LC Sample Cartridges or Cooling Blocks.
MagNA Pure LC Barcode Printer TLP 2844
The MagNA Pure LC Barcode Printer TLP 2844 facilitates sample identification, tracking, and documentation during MagNA Pure LC purification runs. It enables the user to print bar codes created by the MagNA Pure LC Software Version 3.0 for the MagNA Pure LC Sample Cartridges and/or non-barcode-labeled primary tubes. The MagNA Pure LC Barcode Labels (available separately, Cat. No. 03 531 520 001) are suitable for the new bar-cod…
MagNA Pure LC Barcode Labels
The MagNA Pure LC Barcode Labels are designed for use with the MagNA Pure LC Barcode Printer TLP 2844 (Cat. No. 03 576 094 001). The labels are suitable for the new bar-code labeling area of the MagNA Pure LC Sample Cartridge.
MagNA Pure LC Barcode Printer Ribbon
The MagNA Pure LC Bar code Printer Ribbon is designed for use with the MagNA Pure LC Barcode Printer TLP 2844 (Cat. No. 03 576 094 001).
Costar® Spin-X® Centrifuge Tube Filters, 0.22 µm Pore CA Membrane, Nonsterile, 100/Case
Corning Life SciencesThese Costar® Spin-X® centrifuge tube filters have a 0.22 µm pore CA membrane-containing filter unit within a 500 µL capacity polypropylene microcentrifuge tube. Cellulose acetate (CA) membranes provide fast flow rates and low protein binding Ideal for removing bacteria, particles, or cells from liquids, HPLC sample preparation and DNA removal from agarose or acrylamide gels. Nonsterile and certified nonpyrogenic and DNase-…
DNASIS
Hitachi Software Engineering Europe S.A.DNASIS - The Most Comprehensive Software Package for Sequence Analysis. All you expect from gene analysis programs is available in DNASIS. In fact, sequence analysis customers have used versions of DNASIS for over 10 years. Hitachi DNASIS has been proven on the job by scientists worldwide to be quick, accurate and reliable. Features of DNASIS include:Comprehensive : an exhaustive list of highly developed sequence analysis…
Sorcerer UDS for Unscheduled DNA Synthesis
Perceptive InstrumentsSorcerer UDS provides flexible approach to the UDS assay based upon our Sorcerer automatic image analysis system. The system is a fully validated suite of software for UDS compliant with Good Laboratory Practice and FDA 21 CFR Part 11, consisting of a series of modules for creating studies, randomisation, slide scoring, data saving and production of experimental summaries. Interactive automated scoring with calculation of n…
Corning® 28 mm Diameter Syringe Filters, 0.2 µm Pore SFCA Membrane, Sterile, Individually Packaged, 50/Case
Corning Life SciencesThese Corning® syringe filters have acrylic copolymer housings, female Luer lock inlets and male Luer slip outlets. Surfactant-free cellulose acetate (SFCA) membranes provide the lowest protein binding 100% integrity tested, sterile and certified nonpyrogenic and noncytotoxic Manufactured in accordance with ISO 9001 standards
Corning® 150 mL Bottle Top Vacuum Filter, 0.45 µm Pore 13.6cm² CA Membrane, Fits 45 mm Diameter Necks, Sterile, 48/Case
Corning Life SciencesFits plastic or glass media bottles with 45mm neck sizes. Cellulose acetate (CA) membranes provide fast flow rates and low protein binding and are good for filtering cell culture media. Angled hose connector simplifies vacuum line attachment. Individually packaged, sterile and certified nonpyrogenic. Each system has the membrane material and pore size printed on the unit and is color-coded by membrane type for easy produ…
Corning® 15 mm Diameter Syringe Filters, 0.2 µm Pore RC Membrane, Sterile, Individually Packaged, 50/Case
Corning Life SciencesThese Corning® syringe filters have polypropylene copolymer housings, female Luer lock inlets and male Luer slip outlets. Regenerated cellulose (RC) membranes are the best choice for DMSO compatibility. 100% integrity tested, sterile and nonpyrogenic and noncytotoxic Manufactured in accordance with ISO 9001 standards
Corning® 500 mL Bottle Top Vacuum Filter, 0.2 µm Pore 33.2cm² Nylon Membrane, Fits 45 mm Diameter Necks, Sterile, 12/Case
Corning Life SciencesFits plastic or glass media bottles with 45mm neck sizes. Nylon (NY) membranes are naturally hydrophilic, surfactant-free and offer the lowest extractables. Angled hose connector simplifies vacuum line attachment. Individually packaged, sterile and certified nonpyrogenic. Each system has the membrane material and pore size printed on the unit and is color-coded by membrane type for easy product identification. Expiratio…
Table Top Laboratory Animal Anesthesia System V1
KF Technology SrlOne dial setting delivers a consistent and safe anesthetic level. Manuals include a "cookbook" protocol which can easily be adapted to your facility's SOP. All waste gases are scavenged for easy evacuation. Breathing circuits allow flat, prone or supine positions with head access. Suitable for mouse, rat, hamster, gerbil, guinea pig, ferret, rabbit, cat, dog or small swine.Positive sealing gasket on induction chambers minimize…
Bioscan BioFLECT™ 400
Bioscan Inc.The new Bioscan BioFLECT 400 is the first in vivo optical imaging system offering true 360° fluorescence tomography. BioFLECT uses the photon emission data acquired from 360° and a state-of-the-art 3D reconstruction engine to quantitatively reconstruct the 3D spatial distribution of fluorescent probes in live animals. This approach yields superior, consistent resolution, sensitivity and quantitation throughout the subject. The…
Lago
Spectral Instruments ImagingSpectral Instruments Imaging's LAGO offers high throughput imaging for BLI & FLI. With 10 mouse campacity, the LAGO is a fantastic option for high volume imaging cores. This workhorse is designed for non-stop imaging and is the gold standard in sensitiviy - 36% more sensitive than the leading competitor. The LAGO also provides Absolute Calibration, -90C Air Cooled CCD Camera, LED Fluorescence excitation and free software.
Tube Auditor™
Brooks Life SciencesThe Tube Auditor™ measures sample volumes and detects precipitate using high-speed vision technology. It gives confidence in the quality of your samples (at both collection and output) and helps reduce downstream costs and waste, which can arise from empty wells and precipitated samples. Applications include Compound Management, High Throughput Screening and Biobanking.
EXP® Trap Columns
Optimize Technologies, Inc.The patent-pending EXP® Trap Column is rated for use at 20,000+ psi (1,400+ bar). This unique design connects directly to any injection valve (with 10-32 threads) or in-line with 1/16” stainless tubing for unparalleled convenience and efficiency. The EXP® Cartridge System enables chemists to quickly remove detergents or salts which can affect the ionization process in MS work. This trapping technique can concentrate the sampl…
EXP® Stem Trap
Optimize Technologies, Inc.The entire EXP® Stem Trap and reusable holder are only slightly larger than a standard HPLC fitting. Its slim architecture allows it to easily fit into crowded instrument compartments or to connect directly to tightly-spaced injection ports. When tightened by hand, the EXP® Stem Trap seals to 8,700+ psi. All configurations incorporate wrench-flats to enable flawless sealing to 20,000+ psi (1,400+ bar). The unique packed floati…
EXP® Stem Filter
Optimize Technologies, Inc.The EXP® Stem Filter features a choice of frit porosities integrated with our patented auto-adjusting stem for repeated ZDV connections with any 10-32 port. The entire filter stem and reusable holder are only slightly larger than a standard HPLC fitting. This slim architecture allows it to easily fit into crowded instrument compartments, tightly spaced injection ports, and anywhere else you need an extra level of protection ag…
EXP® Nano Trap
Optimize Technologies, Inc.The EXP® Nano Trap System is designed to remove detergents or salts which can affect the ionization process in MS work rated for routine use up to 20,000 psi.The new nano-scale traps are available in two formats – EXP® Nano Trap and EXP® Nano Trap HR. Both formats are available in 10 or 20 mm lengths and in a variety of bed volumes ranging from 0.25µL - 4.0µL. The EXP® Nano Trap follows a traditional trap column format, design…
OPTI-SOLV® Solvent Reservoir Filter
Optimize Technologies, Inc.OPTI-SOLV® Reservoir Filters employ a unique conical design inside the filter housing to prevent air bubbles from getting trapped and disturbing your analysis. While the availability of HPLC-grade solvents diminishes the need for pre-filtering, it is still imperative that a filtration device be installed in the reservoir. Placing a filter in the reservoir is an economical way to filter particles that may result from buffer sal…
OPTI-SOLV® Biocompatible Solvent Reservoir Filter
Optimize Technologies, Inc.A solid PTFE body keeps OPTI-SOLV® filter at the base of the bottle where a bottom-mounted titanium frit provides unrestricted solvent access. As always, Optimize makes installation as simple as possible - no tools or fittings required and includes 5 feet of pre-installed PTFE tubing. OPTI-SOLV Reservoir Filters employ a unique conical design inside the filter housing to prevent air bubbles from getting trapped and disturbing…
OPTI-SOLV® In-Line Hand-Tight Filter System
Optimize Technologies, Inc.The user-friendly Hand-Tight OPTI-SOLV® In-Line Filter System is well suited for a number of applications, such as high temperature, high-pressure environments where quick changes are imperative. The unique swivel design allows frits to be changed without removing the connecting tubing. Just plumb it once and leave it. The frictional forces generated at the piston/seal interface inevitably lead to particulate shedding. Placeme…
OPTI-SOLV® In-Line Wrench-Tight Filter
Optimize Technologies, Inc.The user-friendly Wrench-Tight OPTI-SOLV® In-Line Filter System is well suited for a number of applications, such as high temperature, high-pressure environments where quick changes are imperative. The unique swivel design allows frits to be changed without removing the connecting tubing. Just plumb it once and leave it. The frictional forces generated at the piston/seal interface inevitably lead to particulate shedding. Place…
OPTI-LYNX™ Quick Connect Trap Columns
Optimize Technologies, Inc.The OPTI-LYNX™ Quick Connect Trap Columns allow you to quick-connect to any 10-32 valve/port for trapping or analytical column for pre-column filtration. With OPTI-LYNX™, accessing and changing the insert takes only a quarter turn. Replace traps, filters or change configurations in seconds, without tools. OPTI-LYNX™ traps and filters (ordered separately) come in several bed volume/ diameter/ porosity combinations, allowing you…