Cecil CE 4040 Solvent Degasser (4 Channel)
Cecil Instruments LimitedThis four channel degasser is very efficient at degassing mobile phase, as and when required.
Separations is a fundamental scientific discipline focused on the isolation and purification of components from mixtures. Through techniques such as chromatography, distillation, and filtration, separations scientists separate substances based on their physical or chemical properties. This field plays a crucial role in various industries, including pharmaceuticals, food and beverage testing, environmental science, materials research, and more. Explore how separations techniques enable precise analysis, quality control, and the development of innovative products.
This four channel degasser is very efficient at degassing mobile phase, as and when required.
The FE280 is a basic, simple, routine instrument which allows conductivity to be measured across 4 ranges with full temperature compensation. The temperature coefficient is set at 2%/oC. Ideal for standard applications such as water quality measurements or spot checks on on-line equipment.
The automatic FE287 is much more than a conductivity meter. The related mesurement of resistivity and total dissolved solids are of course possible, but in addition, salinity and concentration measurements can be performed, making the meter one of the most flexible available. Six ranges of conductivity are possible and are selected automatically. Readings are displayed in multiples of S/cm or S/m.
The BA380 is a basic, bench conductivity meter. It measures conductivity only, using automatic temperature compensation and, despite its simplicity, affords the user measurements accurate to plus or minus 1%. The meter is calibrated to one point using traditional manual controls and a conductivity standard. Once the calibration is set, the user may select the appropriate range for the sample and read conductivity value directl…
The GP383 is a general purpose meter. Conductivity and temperature measurements can both be achieved, temperature compensation being either manual or automatic. Once calibrated against a standard solution, the cell constant can then be inspected. Know cell constants may be entered directly. The GP383 has a recorder output for use with recorders or dataloggers.
Apart from conductivity, the user is able to measure: resistivity; total dissolved solids; salinity and temperature. These modes may all be accessed without the need to change cell or calibration and are all temperature compensated. One of the most common application areas of conductivity mesurement is concentration control. The RE388TX may be calibrated in concentration units and a sample concentration then read directly from…
The DR359TX is an advanced, ion concentration meter which automatically calculates the relationship between two or more concentration standards and stores this in memory allowing unknowns to be read directly. Anion/cation recognition is automatic and up to 5 calibration points may be entered, enabling the user to cover a wide dynamic measurement range with just one calibration. The DR359TX also provides full pH facilities incl…
These Costar® Spin-X® centrifuge tube filters have a 0.45 µm pore CA membrane-containing filter unit within a 500 µL capacity polypropylene microcentrifuge tube. Cellulose acetate (CA) membranes provide fast flow rates and low protein binding Ideal for removing bacteria, particles, or cells from liquids, HPLC sample preparation and DNA removal from agarose or acrylamide gels. Sterile and certified nonpyrogenic and DNase-/RN…
These Corning® syringe filters have acrylic copolymer housings, female Luer lock inlets and male Luer slip outlets. Polyethersulfone (PES) membranes provide the fastest flow rates, low protein binding and low extractables 100% integrity tested, sterile and certified nonpyrogenic and noncytotoxic Manufactured in accordance with ISO 9001 standards
The Direct Connection UNIGUARD allows the guard cartridge outlet to be directly placed against the analytical column inlet frit. Product detail: We recommend all analytical columns are protected by a guard cartridge, which is replaced on a regular basis. The ID of the analytical column determines the correct ID for the guard cartridge. We offer 10x1, 10x2, 10x3, 10x4mm guard cartridges in all our stationary phases to ensur…
The Javelin guard design is a one-piece format that can be installed without wrenches and requires no holder, which allows quick and easy replacement. Product detail: We recommend all analytical columns are protected by a guard column or cartridge, which is replaced on a regular basis. The ID of the analytical column determines the correct ID for the guard, so we offer 1.0, 2.1, 3.0 and 4.0 diameter Javelin guard columns in…
MultiSEP™ solid phase extraction wells from Thermo Electron offer robust and reproducible sample preparation and pre-concentration on a routine basis.Wells are available in pre-assembled plate format or as individual wells to allow customisable plates to be assembled by the user.Sorbent packings include the ever-popular silica based bonded phases and also include novel and unique chemistries for specialised applications. Multi…
HyperREZ™ columns are specially designed for analysis of organic acids, alcohols, saccharides and carbohydrates. They employ a polymeric support with ligand exchange groups. The ligand exchange resins contain highly sulfonated cation exchange resins that have Group I, Group II or transition metals associated with the chromatographic surface.HyperREZ™ columns are based upon a polymeric resin that shows stability from pH 1 to 14…
BioBasic 8 Columnso Improved reproducibility, efficiency and column lifetimeso Range of stationary phases to optimize selectivityo Powerful resolution, even on short column lengths Product detail:BioBasic 8 columns provide exceptional reliability for separations of proteins, peptides, and other biomolecules through a combination of high purity silica and reproducible, stable bonding. The proprietary bonding procedure en…
BetaMax Acid Columns o High surface area area and bonded phase coverage for maximum retention, even in high percentage organic conditionso Chemistries for acidic compounds Product detail: For alternative selectivity to traditional alkyl phases, we recommend you try the polar embedded phase BetaMax columns. The stationary phase contains urea groups embedded within the C12 chain, which extra interactions with samples to…
BETASIL C18 Columnso Broad range of particle sizes and phases for wide method development optionso High surface area and phase coverage for reproducibility and sharp peak shapes Product Detail BETASIL columns are based on 100Å pore size, fully deactivated type B silica to ensure sharp peaks and excellent reproducibility for the analysis of a wide range of compounds. The 100Å pore size gives a higher concentration of statio…
BetaBasic 4 Columnso Excellent peak shapes for basic compoundso Superb stability at both low and high pH Product detail:BetaBasic 4 columns are based on a 150Å pore size, fully deactivated type B pure silica to ensure sharp peaks and excellent reproducibility for the analysis of basic compounds. Due to stable bonding chemistry and excellent surface coverage, BetaBasic 4 columns show excellent peak shape for basic compound…
Hyperbond™ is a cost effective alternative to µBondapak (a trademark of Waters Corporation). It is based on an irregular silica with 10µm particle size.
o 100% porous graphitic carbon with very different selectivity to reversed-phase silica columnso Exceptional retention of very polar compoundso Separation of structurally similar compoundso Stable from pH 1 to 14 at high temperatures in a wide range of solvents Product detail: Hypercarb is a unique material for HPLC manufactured by Thermo Hypersil-Keystone. Hypercarb consists of fully porous spherical carbon particle…
o Separate hydrophobic and ionic compounds in a single runo Select from two mixed mode phases, using either cation or anion exchange combined with C18o Retention of compounds is optimized using mobile phase pH, ionic strength and percent organic Product detail: Hypersil Duet columns are an ideal choice for unknown compounds and metabolism studies, as they can separate hydrophobic and ionic compounds in a single analysis…
The Hypersil SAX is recommended for analysis of small organic molecules and organic acids. Product detail: Hypersil SAX is a strong anion exchange column, which is typically used for analysis of small organic molecules and organic acids. As the columns are based on the first generation classical 120Å pore size silica they are not recommended for analysis of biomolecules. For new methods we recommend trying our latest ion…
Thermo Electron Hot and Cool Pockets™ offer unbeatable value in coulmn temperature control. The pockets are small and light weight yet offer precise temperature control. Hot pockerts heat from 5 to 85 oC with a temperature accuracy of ±2oC over the entir range, and a temperature stability of ±0.1Oc. Hot Pockets™ and Cool Pockets™ are not available within the European Union at the present time. We apologise for any inconvenien…
A new screw cap that has been introduced for HP users, to enable them to use a screw top vial on a robotic arm autosampler.