OHpak SB-804 HQ
Showa Denko Europe GmbHPolymer-based column for aqueous Size Exclusion Chromatography (GFC) suitable for light scattering detector.
High performance liquid chromatography (HPLC) and ultra high performance liquid chromatography (UHPLC), also known as UPLC, are analytical techniques used to separate, identify and quantitate components of complex mixtures including biological samples such as proteins and lipids as well as chemical mixtures of pesticides, drugs and oils. Both techniques are liquid chromatographic methods but differ by operating pressures (HPLC < 6000 psi < UHPLC ). Components of HPLC and UHPLC systems include columns, detectors, pumps, autosamplers and column heaters. Explore a range of UHPLC and HPLC columns for your specific sample needs including reverse phase, normal phase, ion exchange, HILIC, ion exclusion and size exclusion columns. For more specialized HPLC, explore FPLC, countercurrent LC and simulated moving bed systems. Find the best UHPLC and HPLC equipment in our peer reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.
Polymer-based column for aqueous Size Exclusion Chromatography (GFC) suitable for light scattering detector.
Polymer-based column for aqueous Size Exclusion Chromatography (GFC) suitable for light scattering detector.
Polymer-based column for aqueous Size Exclusion Chromatography (GFC) suitable for light scattering detector.
Polymer-based column for aqueous Size Exclusion Chromatography (GFC) suitable for light scattering detector.
Silica based Hybrid column, designed for Protein and Antibody analysis, High perfomance, light scattering ready
Using the Nexera™ Prep HPLC system saves on labor when scaling up from the development of analytical conditions to the conditions for preparative work.
The µPAC™ capLC columns are designed for increased robustness and throughput assuring sensitivity. A flow rate versatility between 1 and 15 µL/min at moderated pressures allows short gradient separations, while the µPAC™ technology ensures an exceptional high reproducibility over time and across laboratories. µPAC™ column, 50cm length, with pillar array backbone at interpillar distance of 2.5 µm, C18.
The Affinity Removal LC Column - Human Albumin is designed to chromatographically remove the most interfering high-abundance protein (albumin) from human samples (e.g., plasma, serum, urine, or cerebrospinal fluid). They are compatible with most FPLC or HPLC pumps or instruments, including Agilent 1200/1100 instruments.
Agilent AdvanceBio SEC columns ensure easy, fast, and accurate quantitation for mAb aggregation and fragment analysis. AdvanceBio SEC offers two different particle sizes, 2.7 and 1.9 µm.
Agilent Bio SEC-3 HPLC columns are a breakthrough technology for size exclusion chromatography (SEC). They are packed with spherical, narrowly dispersed 3 µm silica particles coated with a proprietary hydrophilic layer.
Agilent Bio SEC-5 HPLC columns are packed with 5 µm silica particles coated with a proprietary, neutral, hydrophilic layer for maximum efficiency and stability. Our specially designed packing also promotes high pore volume, improving both peak capacity and resolution.
Method validation is a critical step for biotherapeutic drug development. It ensures that the analytical method is suitable for its intended purpose, and that it meets regulatory requirements.
Agilent ZORBAX GF-250 and GF-450 size exclusion (gel filtration) columns are for size separations of proteins and other biomolecules. The separation range is 4,000-900,000 for globular proteins when using GF-250 and GF-450 columns in series.
Agilent AdvanceBio MS Spent Media columns are HILIC columns that deliver fast, sensitive, and reproducible separations of underivatized amino acids and other polar metabolites found in bioprocessor cell culture media for mass spectrometric detection.
Agilent Bio Ion-Exchange HPLC columns are packed with polymeric, nonporous, ion-exchange particles. Bio Ion-Exchange Columns are designed for high resolution, high recovery and highly efficient separations of peptides, oligonucleotides and proteins.
Thorough characterization of monoclonal antibodies includes the identification and monitoring of acidic and basic isoforms. The Agilent Bio MAb HPLC columns feature a unique resin specifically designed for high-resolution charge-based separations of monoclonal antibodies.
PL-SAX for Biomolecules is ideal for the anion-exchange HPLC separations of proteins and deprotected synthetic oligonucleotides under denaturing conditions.
PL-SCX is a macroporous PS/DVB matrix with a very hydrophilic coating and strong cation-exchange functionality.
ZORBAX Ion Exchange columns are available as both Strong Anion-Exchange (SAX) and Strong Cation-Exchange (300SCX) columns.
Agilent 2-AA (formerly ProZyme) labeled N-glycan standards and libraries are commonly used as qualitative standards for LC/FLD and LC/MS.
Agilent 2-AB (formerly ProZyme) labeled N-glycan standards and libraries are commonly used as qualitative standards for LC/FLD and LC/MS.
Agilent 2-AB (formerly ProZyme) labeled O-glycan standards are commonly used as qualitative standards for LC/FLD and LC/MS.
Agilent APTS (formerly ProZyme) labeled glycan standards are commonly used for qualitative N-glycan identification or as migration standards for capillary electrophoresis with laser-induced fluorescence (CE/LIF).
Agilent Blood Group Oligosaccharides (formerly ProZyme) standards are offered as disaccharide and trisaccharide forms.