Purge and Trap Supplies
Agilent TechnologiesFind supplies for the following Teledyne Tekmar purge and trap instrumentation
Find supplies for the following Teledyne Tekmar purge and trap instrumentation
Agilent's QuickSwap Capillary Flow Technology module and pre-swaged fused silica tubing restrictors can increase the productivity of your Agilent 5973N and 5975 inert MSD systems, allowing you to change columns without venting the MSD. QuickSwap not included.
SilTite (Metal) Ferrules Agilent offers a comprehensive selection of ferrules made of different materials and configurations for a a leak-free connection between the column and injector. SilTite ferrules are used with Agilent Ultimate Union and other Capillary Flow Technology products, including the Purged Effluent Splitter (G3180B), Deans Switch device (G2855B), and QuickSwap Mass Spec Interface (G3185B).
Even small leaks in the split/splitless injection port can reduce system sensitivity, cause poor signal to noise ration, increase column bleed, and even shorten column lifetime. Using a patent pending manufacturing process, our inlet gold seals eliminate tiny leaks from machining that can negatively impact your GC performance.
Agilent high-quality copper, stainless steel, and UltiMetal Plus tubing are manufactured and cleaned for chromatographic use. Agilent Tubing comes in different lengths and depending on your flow requirements, are available in 1/16 inch, 1/8 inch, or 1/4 inch. UltiMetal Plus tubing comes in 1/16 inch for inert environments.
Agilent offers a comprehensive selection of ferrules made of different materials and configurations for a a leak-free connection between the column and injector. Graphite-Vespel ferrules can withstand temperatures as high as 280 °C.
The Agilent C15 Component Leak Detector is a modular leak-testing package intended for applications in which the leak detector components are integrated into the system. It incorporates Agilent's Contra-Flow vacuum design, which maximizes the protection of its components from contamination in industrial applications. An optional color touch screen display is available for remotely showing all system status information and i…
The PHD-4 sniffer leak detector is a lightweight and rugged sniffer, sensitive to helium concentrations as low as 2 ppm – equivalent to a leak rate of 5 x 10–6 atm-cc/sec, far superior to bubble-testing, dye penetrants, and pressure decay. The sensitivity of the PHD-4 is enabled by Agilent’s proprietary and patented SIPD (Selective Ion Pump Detection) technology. With automatic startup, self-test and calibration, the PHD-4…
We supply a wide range of GC accessories to fit most common GC systems. We can provide Prep GC, sniffer systems, cryogenic trapping either with a GC or as a retrofit
Young Lin GC products have been developed for more than 15 years with an accumulated experience in chromatographs. The YL6100 GC meets all analytical demands providing practical solutions for every application and satisfying the features you’ ve always desired. APC is a standard function in gas chromatography. You can enjoy all the advantages of multi-functional APC with our YL6100 GC. Our multi-functional APC increases produc…
Agilent J&W VF-WAXms is a high performance column for applications in the food, flavor and fragrance markets, and especially where trace analyses are required.
PC/Chrom is a complete package that interfaces your GC or HPLC detector to your personal computer or to a corporate network server. PC/Chrom reads the analog output signal from the detector, digitizes the signal, displays the chromatogram, and processes the data according to user specifications to produce a final report that can be printed. All hardware and software is included in the PC/Chrom package, including power supply a…
Labformatics Balanced Scorecard Approach combines the laboratory performance measurement service suite of Labformatics with the powerful CorStrategy Balanced Scorecard engine from CorVu plc. Over 65% of Fortune 500 organisations are thought to use the Balanced Scorecard approach as part of their business performance management activities. Labformatics Balanced Scorecard Approach is the only product specifically designed fo…
The newest member of the PDD family is also the smallest and thriftiest. The miniPDD uses about one fifth (20%) the amount of helium as the D-3 and D-4 versions, giving up only a bit of sensitivity and dynamic range in return. It is approximately one half the size of the D-4, but has nearly the same sensitivity — about 100 ppb for fixed gases. With its reduced size, weight, and helium consumption, it is particularly well sui…
Bruker’s innovative PIONA+™ Analyzer, based on the powerful 450-GC gas chromatograph, provides a highly flexible platform to obtain comprehensive characterization and quantitative information, including hydrocarbon group types, aromatics and oxygenates per carbon number for spark emission fuels. The system comes complete with ultra high performance columns and traps, CompassCDS™ chromatography data handling software and PIONA+…
Use this automated and user-programmable helium conservation module on an Agilent 8890, 8860, or 7890 GC to significantly reduce your helium consumption, especially when combined with Agilent Gas Saver.
Agilent J&W HP-PLOT Q is a bonded polystyrene-divinylbenzene (DVB) column specially developed for the separation of targeted nonpolar and polar compounds, including hydrocarbons (natural gas, refinery gas, ethylene, propylene, all C1-C3 isomers); CO2, methane, air/CO, and water; polar solvents (methanol, acetone, methylene chloride, alcohols, ketones, aldehydes, esters); and sulfur compounds (H2S, mercaptans, COS).
Agilent DB-Sulfur SCD columns are optimized for use with Sulfur Chemiluminescence Detection (SCD) to provide low bleed performance and reduced SCD ceramic tube fouling.
HT3000A is a liquid GC autosampler that offers reliability and superior performance for all GC-GCMS applications. The HT3000A is the most compact autosampler on the market, with a near-to-zero requirement for bench space, while offering a top-class sample capacity (121 positions for 2ml vials). The sample rack can be removed for sample loading or preparation, or for storage elsewhere.It can be easily installed on all the GC a…
HT3100A is a liquid GC autosampler that offers automation for processing up to 15 unattended samples. It handles the most sophisticated sampling techniques: Multi-phase sampling, Sandwich injection, Priority sampling, Ambient headspace sampling, Nanoliter injection. It can be easily installed on all the GC and GC/MS systems available in the market, because of flexibility and modular configuration. It can be configured to serv…
HT3200A is a liquid GC autosampler, that takes advantage of today’s latest technology to deliver even greater reliability, performance, as well as offering an extraordinary GLP experience. The HT3200A has a top class sample capacity: no other offers so many samples (209 2mL sample vials) with near-to-zero bench space requirements.Key features: Easy to use Support all GCs of your lab Fast injection technology Versatili…
The HT2100H is an inexpensive, simple-to-use, as well as reliable headspace unit. With all the quality and reliability you expect, the HT2100H headspace sampler offers exactly the features you need — at a price to fit your budget.The HT2100H is a quality, cost-effective alternative to manual headspace. While manual sampling techniques are simple and inexpensive, they are also tedious, subject to human error and they are not a…
SLB-IL60 Ionic Liquid Capillary GC ColumnApplication: Modified (deactivated) version of SLB-IL59 provides better inertness. Selectivity more polar than PEG/wax phases, resulting in unique elution patterns. Higher maximum temperature than PEG/wax columns (300 ºC compared to 270-280 ºC). Excellent alternative to existing PEG/wax columns. Also a good GCxGC column choice. Launched in 2012.USP Code: NonePhase: Non-bonded; 1,12-Di(t…
SLB-IL59 Ionic Liquid Capillary GC Column• Application: Selectivity more polar than PEG/wax phases, resulting in unique elution patterns. Higher maximum temperature than PEG/wax columns (300 ºC compared to 270-280 ºC). Great choice for analysis of neutral and moderately basic analytes. Launched in 2009.• USP Code: None• Phase: Non-bonded; 1,12-Di(tripropylphosphonium)dodecane bis(trifluoromethylsulfonyl)imide• Temp. Limits: Su…