Reference Materials for cannabis testing labs
LGC - Dr. EhrenstorferDedicated to providing the most comprehensive offering of reference materials for cannabis and hemp testing
Dedicated to providing the most comprehensive offering of reference materials for cannabis and hemp testing
The Agilent 7650A Automatic Liquid Sampler (ALS) provides reliable, fast, and precise injections for Agilent GC and GC/MS systems.
MicroSolv Technology Corporation Headspace vials and caps help get reproducible results when performing headspace analysis. If you're attempting to meet USP <467> Residual Solvent Analysis, environmental testing, forensic testing, or any other type of analysis, these vials and caps take the worry out of choosing the proper consumables. All these vials and caps pass stringent QC tests for overall form, autosampler fit, and fun…
Maximize the operational efficiency and profitability of your lab with the Thermo Scientific™ TRACE™ 1600 Series Gas Chromatograph and its unique modular concept for optimized instrumental usage. The instrument features an enhanced workflow experience through its advanced multi-functional touch screen with instrument health monitoring, how-to videos, and full instrument control through the chromatography data system.
Elite-1, 100% dimethyl polysiloxane, columns are highly versatile, non-polar, cross-linked general purpose columns that are rugged, exhibiting long column lifetime, low bleed, and high maximum operating temperatures.
The Elite-5 is a 5% diphenyl/95% dimethyl polysiloxane stationary phase. It is regarded as a general purpose, low polarity phase that is the most popular GC stationary phase. The Elite-5 is a crosslinked phase in which all residual catalysts and low molecular weight fragments have been removed providing a tight mono-modal distribution and extremely low bleed.
The Elite-5ms phase (5% 1,4-bis(dimethylsiloxy)phenylene, 95% dimethyl polysiloxane) incorporates a phenyl group in the polymer backbone to improve thermal stability, reduce bleed and make the phase less prone to oxidation. This results in inertness to active compounds and extremely low bleed for sensitive MS applications.
The DynamiQ-S is a micro gas chromatograph for fast and accurate gas analysis in industrial processes and factory automation applications. The instrument can be programmed for continuous unattended process monitoring as well as manual gas analysis. Extremely compact, easy to handle and requiring little maintenance, the DynamiQ-S enable fast and accurate on-line ga analysis anywhere. The integrated micro GC chips enable analys…
Certified reference material, Trace CERT ® , 100 μg/mL each component in methanol, ampule of 1 mL.
Get systematic chemical names for structures and produce structures from names - ACD/Name generates chemical names according to IUPAC rules, converts chemical names to structures, and easily handles challenging areas of nomenclature.
AZUR 4.0 The latest version of chromatography data system for stand-alone acquisition and analysis. Many new features including enhanced reporting capabilities and the new 24 bit USB interface. USB or PCI interface up to 4 independant channels Simple user interface Advanced functionality Low cost academic version
Determining the Carbon, Hydrogen, Nitrogen, Oxygen, and Sulphur (CHNS-O) content of unknowns is one of the most basic and essential needs of any chemist. Clarity Elemental Analysis Software is based on proven Clarity Chromatography Software. This solution provides a simplified version of the Clarity user interface that speeds up the workflow with elemental analyzers equipped by autosamplers. Clarity Elemntal Analysis Softwar…
VICI introduces the GC detector where the PDD (pulsed discharge detector) utilizes a stable, low-powered, pulsed DC discharge in helium as the ionization source. The D-2 is a dual mode, universal detector system which can be retrofitted to your older GC. The D-2-I is a helium photoionization detector, optimized for trace level work with packed columns. The stand-alone systems include detector, controller, electrometer, helium…
Pulsed discharge detector Model D-3 is designed for plug-and-play installation on Agilent GC's, with models available for the 6890 and 7890. The D-3 is optimized for trace level work in the helium photoionization mode, and utilizes the electronics and power supply of the host GC. Model D-5 is optimized for electron capture detection. Available for 110 VAC and 230 VAC.
Model D-5 is a pulse discharge GC detector designed for plug-and-play installation on the Agilent 6890. The D-5 is optimized for trace level work in the electron capture mode, and utilizes the electronics and power supply of the host 6890. Model D-3 is optimized for helium photoionization detection. Available for 110 VAC and 230 VAC.
Model D-4 a GC Detector available in versions for easy installation on most of the GC's in current use, including the Varian 3800, Shimadzu 14 and 17, ThermoFinnigan Trace, Mega, and Top, and Hewlett Packard 5890. The D-4 is single mode, optimized for trace level work in the helium photoionization mode. Available for 110 VAC and 230 VAC.
Model D-6 is a single mode GC detector, optimized for trace level work in the electron capture mode. IT is available in versions for easy installation on most of the GC's in current use, including the Varian 3800, Shimadzu 17, ThermoFinnigan Trace, Mega, and Top, and Hewlett Packard 5890. Available for 110 VAC and 230 VAC.
Reduced breakdown liners Our improved injection port liner reduces breakdown of endrin and DDT during injections while increasing the interval between liner changes. The problem DDT and Endrin are easily degraded in the injection port; with non-deactivated liners and those filled with non-deactivated glass wool, Endrin breakdown can be as high as 98%. EPA method 8081A states "If degradation of either DDT or Endrin exceeds 15%,…
VICI AG uses proprietary liquid phase processing to produce low bleed characteristics while maintaining identical retention characteristics to the phases you are used to. These processes combined with proprietary coating, curing, bonding, and crosslinking produce MS-certified bleed characteristics equal to the best. Improved upper temperature limits enhance column "bake out", reducing sample carryover and cycle times. ValcoBon…
Now you can reduce run time, faster than micropacked, by replacing your packed columns with ValcoPLOT HayeSep capillary PLOT columns, with phases available only from VICI. Our proprietary phase processing produces the first capillary PLOT columns with characteristics identical to HayeSep packed columns. The ValcoPLOT line also includes Molesieve and Alumina PLOT columns. Visit VICI AG website to veiw now.
Permeation tubes are small, inert capsules containing a pure chemical compound in a two phase equilibrium between its gas phase and its liquid or solid phase. They are used to generate a stable concentration of a specific trace chemical. At a constant temperature, the device emits the compound through its permeable portion at a constant rate. They are typically inserted into a carrier flow to generate test atmospheres for c…
Patented G-Cal permeation tubes offer a proven and repeatable means of generating a desired gas or vapor concentrations. The permeant gas escapes through the proprietary membrane system and mixes with a carrier gas (nitrogen is the most common) at a controlled flow rate to obtain a known mixture in ppm or ppb. Applications include calibration of gas monitoring systems and chromatographs, accuracy check of gas detectors, and ge…
Ultra-high capacity for the contaminant of interest; either Moisture, Hydrocarbons, Oxygen, Sulfur and Mercury. For applications with a single contaminant of interest, high capacity contaminant specific traps are your best option, since they generally have four times as much capacity for the specific contaminant as a purifier. This translates to a capacity that exceeds twelve standard type "A" tanks of gas or the equivalent of…
VICI AG heated helium purifier provides point-of-use purification of helium or other noble gases, such as Ar, Ne, Kr, and Xe, to sub-ppm levels of reactive gaseous impurities, removing even nitrogen and methane. The nitrogen purifier is similar, purifying nitrogen to sub-ppm levels of gaseous impurities. The miniature version of each purifier is designed to be installed in a GC’s flow path immediately upstream of the injector.…