Smart Solutions ™ v59 PharmaVetResiMix Kit
LGC - Dr. EhrenstorferThe easiest and quickest way to calibrate and screen for 59 Veterinary Residue analytes. 59 analytes, 4 mixtures in one kit. Quick calibration and mass screening for LC/MS.
Mass spectrometry (MS) is a powerful analytical technique used to identify and quantify molecules based on the mass-to-charge ratio of gas-phase ions. It provides detailed information about the structure, composition, and properties of compounds and is widely used across fields such as environmental monitoring, materials science, drug discovery and development, food and beverage testing, and wider chemical research. Key MS techniques include tandem mass spectrometry (MS/MS), liquid chromatography–mass spectrometry (LS-MS), and inductively coupled plasma (ICP-MS). Choosing from these wide range of techniques and technologies can be a daunting task, so keep up to date with scientific applications, performance expectations, and customer reviews here all in one place. Visit our product directory to receive quotes direct from the manufacturer.
The easiest and quickest way to calibrate and screen for 59 Veterinary Residue analytes. 59 analytes, 4 mixtures in one kit. Quick calibration and mass screening for LC/MS.
SEQUEST Cluster is a complete, preconfigured proteomics solution that enables accelerated throughput of increasingly complex, multidimensional informatics.Product detail:The SEQUEST Cluster offers a scalable solution for computing the large volumes of data typical in most proteomics analyses using LC/MS. Protein database search times are dramatically reduced by harnessing the power of several processing units in one, increasin…
DeNovoX software automates and accelerates sequencing, returning results equal to or better than those formerly achieved through expert manual sequencing of peptides within proteins and is ideally suited for high-throughput analyses of peptide mixtures. Product detail: DeNovoX is a fully-automated de novo sequencing software program that is capable of determining complete or partial amino acid sequences of unknown peptide…
LCquan 2.0 enabling 21 CRF Part 11 compliance. LCQUAN 2.0 is a closed, secure, multi-level user environment for mass spectral quantitative analysis. When LC Quan 2.0 is used in conjunction with Thermo's electronic Record Manager (eRM), this powerful combination provides the user with a completely secure data archival solution. Product detail: LCQUAN 2.0: Quantitation for the regulated laboratories Companies in regulated i…
Plasma Chromatographic Software Agilent Technologies' Plasma Chromatographic Software (Plasma Chrom) enables seamless integration of the Agilent 7700 and 7500 Series ICP-MS with chromatography instrumentation. Developed by Agilent, this optional software features powerful integration, calibration and quantification capabilities for handling chromatographic data. Much more than just a data analysis package, the Agilent Plasma…
Agilent Mass Profiler Professional (MPP) software is a powerful chemometrics platform designed to exploit the high information content of MS data and can be used in any MS-based differential analysis to determine relationships among two or more sample groups and variables.
The Agilent MassHunter METLIN Metabolomics Database and Library enable streamlined metabolite identification to facilitate understanding of global metabolic changes that can occur in a biological system. Available as a comprehensive database of metabolites (PCD) that optionally includes MS/MS spectra (PCDL).
GC/MS Test and Performance Samples Agilent J&W GC Column Test StandardsLC and LC/MS Standards GPC/SEC and GFC Calibration Standards Amino Acids Standards and Reagents CE Standards and Reagents ICP-MS Standards UV-Vis Standards and Reagents Application Specific Standards Residual Solvent Standards SampliQ QuEChERS Standards GC Instrument Evaluation Analyzer Kit Standards GC Instrument Installation and Calibration Standards
The ion source operates by electron ionization (EI) or chemical ionization (CI). The sample enters the ion source from the GC/MSD interface. Electrons emitted by a filament enter the ionization chamber, guided by a magnetic field. The high-energy electrons interact with the sample molecules, ionizing and fragmenting them. The positive voltage on the repeller pushes the positive ions into the lens stack, where they pass throug…
Enzymatic digestion of proteins in polyacrylamide gel slices and subsequent analysis of the peptides by mass spectrometry has become a routine procedure in protein analysis. In solution digestion protocols for bottom-up proteomics complement it. The DigestPro MSi automates all those procedures to achieve high throughput under controlled and reproducible conditions.
The AbsoluteIDQ p180 Kit enables standardized, quantitative and reproducible analysis of ca. 200 endogenous metabolites from several metabolite classes (acyl-carnitines, amino acids, biogenic amines, (lyso-) phosphatidylcholines, sphingomyelins, hexoses, steroids). The metabolite analysis is based on flow injection analysis (FIA-ESI-MS/MS) and LC-ESI-MS/MS. The possibility of measuring different biological matrices of differe…
PHOTONIS Channeltron detectors provide the highest sensitivity due to superior signal collection and noise reduction, effectively improving the efficiency of your mass spectrometer. With over 150 replacement detectors to choose from, we can supply the replacement detector in a wide range of mass spectrometers, even if the instrument is no longer manufactured. Additionally, many of our detectors can be bought as complete repl…
PHOTONIS’ Advanced Performance Detectors (APDs) are plug-and-play electo-optic assemblies which provide a complete housing, facilitating manufacturing assembly, repair or replacement to mass spectrometers and other machines. Available for new machines or as replacement cartridges for existing models, over 200 types, with cartridge-mounted MCP, further simplifying additional repairs. ¶PHOTONIS Advanced Performance Detectors (AP…
PHOTONIS offers the widest and most technologically advanced variety of Time-of-Flight Detectors available. These patented detectors offer previously unobtainable levels of temporal resolution, dynamic range, and high mass detection sensitivity for TOF Mass Spectrometry. PHOTONIS' unique 2-Micron pore MCP provide the highest channel density of any MCP providing gains in excess of 5x106. PHOTONIS manufactures Time-of-Flight Det…
PHOTONIS is the industry leader in technology advancements for Microchannel Plates (MCPs). We offer a broad range of sizes, shapes and options to support a number of imaging applications. Our expertise across two production locations ensures continual research and development while ensuring our customers receive the customization and service for which we are known. For over thirty years, PHOTONIS has consistently set the stand…
Agilent Deconvolution Reporting Software (DRS) for GC/MS is an application for target compound analyses that combines results from the Agilent MSD Productivity ChemStation, the NIST Automated Mass Spectral Deconvolution and Identification Software (AMDIS), and the NIST 2008 Mass Spectral Search Program (NIST08) into one easy-to-read report.
Consolidating your laboratory services with one provider makes excellent business sense. You get one service contract instead of 20 or more for your instruments. You can locate any piece of equipment instantaneously and track every critical event, such as an instrument’s next scheduled service. Efficiencies of scale help you control lab costs and optimize lab operations. OneSource, our consolidated instrument service, is unpar…
The Finnigan vMALDI Ion Source system provides fast, automated MS and Data Dependent MS/MS analysis of digested protein mixtures in a single, rapid experiment. While LC/MS analysis times are typically 30 to 60 minutes, using the Finnigan LTQ with the vMALDI ion source generally requires less than a minute per sample enabling high throughput protein identification. Production: The Finnigan vMALDI Ion Source Thermo's new F…
Mass Spectrometry Software for Spectral Interpretation and Component Characterization
Steroid Analysis – QUICK and EASY: BIOCRATES AbsoluteIDQ® Steroid reagents enable up to 17 steroids from human serum to be quantified simultaneously and reliably using LC-MS/MS. Fully customizable Multiplexing capabilities High-quality, robust and reliable results Proficiency Test Approval (DGKL, Germany)
The new PHOTONIS Ion Mobility Spectrometer (IMS) Analyzer is a complete integrated assembly for simplified IMS analysis that features high resolving power (64-150) in a compact design. The unit combines PHOTONIS’ patented Resistive Glass products with a new robust ion gate technology to create an IMS analyzer which improves resolution and simplifies serviceability. Key components of the IMS Analyzer are made from Resistive Gla…
Inductively Coupled Plasma Mass Spectrometer (ICP-MS) The Science of sensitivity Bruker's ICP-MS is famous for its innovative and unique technology and has now been further refined to meet the ever increasing demands of latest application and laboratory requirements. Bruker's aurora M90 continues to be the workhorse for the routine laboratory, now with additional and improved characteristics. In addition to the aurora M90, Bru…