Gas Chromatography Products & Reviews

25

Gas chromatography (GC) is an analytical technique used to separate and quantitate mixtures of small and volatile compounds. Gas chromatographs or GC systems include components such as GC columns, detectors, pumps and autosamplers. Choose from packed or capillary GC columns, flame ionization (FID), photoionization (PID) electron capture detectors and selective or non-selective detectors. Find the best gas chromatographs in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.

Product Filter

Explore by Field
Gas Chromatography
Refine your selection
Explore by Company

Ratings

Search

Selected Filters:

Syft Tracer

Syft Technologies

Syft Tracer is the next generation of real-time, trace gas analysis by SIFT-MS that is built to solve the most difficult analytical challenges faced within a variety of industries and applications.  It delivers trace-level detection sensitivity, unparalleled performance stability, and highly reproducible, quantitative data.  Syft Tracer is optimized for high-throughput environments where 24/7 operation is the standard.  

5.0/5.0
|1 Review
Request Pricing

Voice200infinity

Syft Technologies

Designed specifically for the demanding cleanroom environment, the Voice200infinity is the class-leading solution for real-time, high-sensitivity AMC analysis in cleanrooms. It analyzes the widest range of VOCs and inorganic compounds with low part-per-trillion by volume (pptV) detection limits. Infinity has the sensitivity and performance required for 24/7 monitoring of AMCs. 

5.0/5.0
|1 Review
Request Pricing

Zebron™ ZB-WAX GC Columns

Phenomenex Inc

PEG Versatility for Solvents, Acids, and AminesBonded, solvent rinsable phase excellent for separating polar complex mixturesGC/MS Certified low bleed levelsLow activity for aminesExcellent separations of polar complex mixtures; widely used for profiling and "fingerprinting"Recommended UseAlcohols, Aldehydes, Aromatics, Basic Compounds, Essential Oils, Flavors & Fragrances, Glycols, Pharmaceuticals, Solvents, Styrene, Xylene I…

4.7/5.0
|3 Reviews

Zebron™ ZB-1 GC Columns

Phenomenex Inc

Low Polarity for a Wide Range of SeparationsRugged, high efficiency, and MS Certified low bleedWell-suited for true boiling point separationsExcellent resolving power of critical pairs in complex petrochemical samplesUsed for “fingerprinting” and routine quality control analyses (e.g., citrus oils)Recommended ApplicationsAmines, Drugs, Essential Oils, Ethanol, Gases (Refinery), Hydrocarbons, Mercaptans, MTBE, Natural Gas Odora…

4.8/5.0
|5 Reviews

Zebron™ ZB-WAXplus GC Columns

Phenomenex Inc

100% Aqueous Stability for Polar Compounds100% aqueous stable, excellent for aqueous samples; bonded and solvent rinseableExtremely inert for acidic compoundsEnhanced selectivity for low boiling solvents; high retention of alcohols and chlorinated solventsIncreased efficiency at 20 °CZB-WAXplus provides optimal selectivity for many aqueous soluble compounds such as those found in alcoholic beverages or glycol samples. The ZB-W…

4.9/5.0
|2 Reviews

Zebron ZB-50 GC Columns

Phenomenex Inc

Rugged Performance for High Polarity SelectivityHigh polarity column capable of high temperature bakeout to remove contaminantsInert to minimize analyte adsorption, improve efficiency, and reproducibilityMore rugged (longer column life) than other polar phasesGreat for toxicology and environmental compoundsRecommended UseAntidepressants, Aroclors, Cholesterols, Drugs of Abuse, EPA Methods (508, 608, 8081, 8141, 8151), Glycols,…

5.0/5.0
|1 Review


Zebron™ PLUS GC Inlet Liners

Phenomenex Inc

Introducing ZebronTM PLUS GC Inlet Liners Zebron PLUS Liners  Optimized for trace and active compound analysis, Zebron PLUS GC liners undergo a unique chemical deactivation treatment resulting in a remarkably inert GC inlet liner. Zebron Essential Liners Zebron Essential liners undergo a vapor deposited deactivation process resulting in a thin film liner that is ideal for routine analysis. Why Use Pre-Packed Liners?…

5.0/5.0
|2 Reviews
Request Pricing

Zebron ZB-Dioxin

Phenomenex Inc

By switching to the unique selectivity of ZB-Dioxin you will gain enhanced resolution of 2,3,7,8-TCDD and 2,3,7,8-TCDF from its isomers in one run, and only need a single ZB-Dioxin GC column as your SINGLE column solution for Dioxin analysis. Upgrade your existing GC column for Dioxin analysis to a Zebron ZB-Dioxin GC column and get all the analytical benefits and productivity gains of a single column solution.

5.0/5.0
|1 Review
Request Pricing

Agilent Select FAME GC Columns

Agilent Technologies

The Select FAME column is tuned for optimal cis/trans separations of FAMEs, especially the C18 isomers. The bonded column has an isothermal maximum operation temperature of 275°C and a programmed temperature of 290°C - a dramatic improvement of 50°C compared to non-bonded columns. Select FAME has better detection limits because the column has a very low bleed level. Even though this is a very polar column, the column efficienc…

4.5/5.0
|2 Reviews


HP-5ms GC Columns

Agilent Technologies

Agilent J&W HP-5ms has very low bleed characteristics that are ideal for GC/MS. The column has excellent inertness for active compounds, including acidic and basic compounds, and improved signal-to-noise ratio for better sensitivity and mass spectral integrity.

5.0/5.0
|2 Reviews

HP-FFAP Columns

Agilent Technologies

Agilent J&W HP-FFAP is designed primarily for the analysis of organic acids, free fatty acids, or samples that require quantitation of acidic impurities. The FFAP stationary phase is modified with acid to provide a very inert column that can accommodate the demanding analysis of acids dissolved in water. 

5.0/5.0
|1 Review

CP-Wax 52 CB columns

Agilent Technologies

CP-Wax 52 CB GC columns have lower minimum temperature and a higher maximum temperature than non-bonded polyethylene glycol (PEG) columns due to extensive cross linking, delivering higher resolution of low-boiling-point analytes. With guaranteed reproducibility and excellent temperature stability, CP-Wax 52 CB is ideal for EPA and ASTM methods.

5.0/5.0
|1 Review

CP-Sil 88 Columns for Dioxins

Agilent Technologies

Agilent J&W CP-Sil 88 for Dioxins has a very high polarity and a specific selectivity for dioxin and dibenzofuran separations. The column is supplied with an integrated retention gap to avoid problems with solvent condensation, thus allowing repeated splitless injections without phase deterioration, extending column life. 

5.0/5.0
|1 Review

DB-624 GC Columns

Agilent Technologies

Agilent J&W DB-624 is recommended for EPA methods 502.2 and 8021, as well as for fast GC/MS volatiles analysis. It is specifically designed for the analysis of volatile priority pollutants and residual solvents.

4.9/5.0
|2 Reviews

7697A Headspace Sampler

Agilent Technologies

Introduce volatile compounds from virtually any sample matrix into your GC or GC/MS. Automatic Leak Check, Priority Sample Positions, and Barometric Pressure Compensation improve uptime and efficiency.

4.7/5.0
|5 Reviews

Capillary Flow Technology

Agilent Technologies

Dependable leak-free capillary connections allow reliable backflush, split flow, heart-cutting, and GC x GC on Agilent 8890 and 7890 GC systems. These devices are low thermal mass, oven mountable, and inert.

5.0/5.0
|1 Review


Purge and Trap

Agilent Technologies

Purge and Trap (P&T) performs highly sensitive volatile organic compound (VOC) analysis with low carryover, allowing accurate and precise GC and GC/MS determination of VOCs in water, wastewater, soils, and sludges.

5.0/5.0
|1 Review


Ultra Inert Liners

Agilent Technologies

Agilent’s Ultra Inert Inlet Liners prevent adsorption and ensure accurate sample transfer onto the GC column through a robust deactivated surface. These liners are recommended for trace level analysis of active analytes. Liners with inert wool retain non-volatiles, prolonging column life and lowering frequency of MS source maintenance.

4.9/5.0
|3 Reviews

Splitless Liners

Agilent Technologies

Agilent offers a complete line of liners for your Agilent GC splitless inlet. Agilent’s proprietary deactivation is important for splitless liners because of the longer sample/liner contact in splitless mode.

5.0/5.0
|4 Reviews

Agilent Syringes

Agilent Technologies

Autosampler and Manual Syringes   For exacting measurement, transport and delivery of liquids necessary for sample preparation and injection, specify Agilents full suite of manual and autosampler syringes.  Designed for accuracy, reliability and ease of use, Agilent syringes enhance productivity and performance through every step of your sample processing.

4.9/5.0
|5 Reviews

Gas Clean Purification System

Agilent Technologies

The Agilent Gas Clean Filter System delivers clean gases, reducing the risks of column damage, sensitivity loss, and instrument downtime. Inserting a Gas Clean Filter System in the gas line immediately before the instrument inlet greatly reduces the level of impurities, thus improving trace analysis. 

5.0/5.0
|1 Review