EZ Load 100 bp PCR Molecular Ruler
Bio-Rad500 µl, 0.08 µg/µl, ready-to-load DNA standard, 100–3,000 bp, 30 bands, includes 1 ml 5x nucleic acid sample buffer, 100 applications
500 µl, 0.08 µg/µl, ready-to-load DNA standard, 100–3,000 bp, 30 bands, includes 1 ml 5x nucleic acid sample buffer, 100 applications
Boiling range: 96 - 98°Cn 18°C/D: 1.3735Density (d 20°C/4°C): 1.085Melting point: -118°CNote: ♦ Attention: All solutions of formaldehyde may contain a precipitate. This has no influence on the application.Formula: CH2OM: 30.03 g/molCAS-No.: 50-00-0HS-No.: 29121100EC-No.: 200-001-8Storage: RTLGK: 6.1 ADisposal: 7R: 23/24/25-34-39/23/24/25-40-43S: 26-36/37/39-45-51hazardidentification: toxic, corrosive, carcinogenic, sensitizing…
Boiling point: 1300°CMelting point: 646°CSolubility (20°C): 1800 g/L (H2O)Density (d 20°C/4°C): 3.983Formula: ClCsM: 168.36 g/molCAS-No.: 7647-17-8HS-No.: 28273985EC-No.: 231-600-2Storage: RTLGK: 10 - 13Disposal: 28WGK: 1Specification: DNases/RNases/Proteases: not detectableAssay: min. 99.999 %
Formula: C2H2O2M: 58.04 g/molCAS-No.: 107-22-2HS-No.: 29121990EC-No.: 203-474-9Storage: 2-8°CLGK: 10 - 13Disposal: 7R: 20-36/38-43-68S: 36/37hazardidentification: irritant, harmful, sensitizingWGK: 1Specification: DNases/RNases/Proteases: not detectableAssay (titr.): approx. 40 %
Melting point: approx. 253°CSolubility (20°C): 222 g/L (H2O)Formula: H2KO4PM: 136.09 g/molCAS-No.: 7778-77-0HS-No.: 28352400EC-No.: 231-913-4Storage: RTLGK: 10 - 13WGK: 1Specification: DNases/RNases/Proteases: not detectableAssay (titr.): min. 99.5 %
Formula: Cl3CoH18N6M: 267.48 g/molCAS-No.: 10534-89-1HS-No.: 28273930EC-No.: 234-103-9Storage: RTR: 36/37/38S: 26hazardidentification: irritantSpecification: DNases/RNases/Proteases: not detectableAssay (titr.): min. 99 %
Density (d 20°C/4°C): 0.944Melting point: -60°Cn 20°C/D: 1.4305Boiling point: 153°CFormula: C3H7NOM: 73.10 g/molCAS-No.: 68-12-2HS-No.: 29241900EC-No.: 200-679-5Storage: RTLGK: 6.1 ADisposal: 1R: 61-20/21-36S: 53-45hazardidentification: toxic for reproduction, harmful, irritantClass/PG: 3/IIIUN-No.: UN2265WGK: 1Specification: DNases/RNases/Proteases: not detectableAssay (GC): min. 99.5 %
Melting point: 116°C (dec.)Solubility (20°C): 1670 g/L (H2O)Formula: Cl2Mg · 6H2OM: 203.30 g/molCAS-No.: 7791-18-6HS-No.: 28273100EC-No.: 232-094-6Storage: RTLGK: 10 - 13Disposal: 14WGK: nwgSpecification: DNases/RNases/Proteases: not detectableAssay (titr.): min. 99.5 %
Formula: C2H3NaO2M: 82.03 g/molCAS-No.: 127-09-3HS-No.: 29152900EC-No.: 204-823-8Storage: RTLGK: 10 - 13WGK: 1Specification: DNases/RNases/Proteases: not detectableAssay (titr.): min. 99 %
Melting point: 175°CSolubility (20°C): 1000 g/L (H2O)Formula: CaCl2 · 2H2OM: 147.02 g/molCAS-No.: 10035-04-8HS-No.: 28272000EC-No.: 233-140-8Storage: RTLGK: 10 - 13Disposal: 14R: 36S: 22-24hazardidentification: irritantWGK: 1Specification: DNases/RNases/Proteases: not detectableAssay (titr.): min. 99.5 %
Boiling point: 123°CMelting point: 58°CSolubility (20°C): 1250 g/L (H2O)Formula: C2H3NaO2 · 3H2OM: 136.08 g/molCAS-No.: 6131-90-4HS-No.: 29152900EC-No.: 204-823-8Storage: RTLGK: 10 - 13WGK: nwgSpecification: DNases/RNases/Proteases: not detectableAssay (titr.): min. 99.5 %
Solubility (20°C): 710 g/L (H2O)Formula: MgO4S · 7H2OM: 246.48 g/molCAS-No.: 10034-99-8HS-No.: 28332100EC-No.: 231-298-2Storage: RTLGK: 10 - 13Disposal: 14WGK: 1Specification: DNases/RNases/Proteases: not detectableAssay (titr.): min. 99.5 %
MFP-3D BIO - The Only Full-Capability AFM on an Inverted Optical Microscope. Uncompromised AFM on an Inverted Optical Platform. The Asylum Research MFP-3D-BIO provides the highest sensitivity and most accurate images and measurements possible on an inverted optical platform. The Best Force Measurements – from the Commercial Pioneer of Force Spectroscopy Asylum Research pioneered commercialization of picoNewton-scale force spe…
EZ-Link Sulfo-NHS-LC-Biotin is an intermediate-length, water-soluble biotinylation reagent for labeling antibodies, proteins and other molecules that have primary amines.
LC/GC Certified vials are tested by LC/UV for residues of chemicals used in processing and packaging vials. The septa are tested by headspace GC to ensure low levels of low molecular weight polymer. These vials are suited for analyte concentration in the µg/mL concentration; typically detectors like UV and RI.
New Inspyra module combines chemists’ expertise with exploratory capabilities of automated compound
Detects apoptotic cells in situ by the indirect TUNEL method, utilizing an anti-digoxigenin antibody that's conjugated to a Fluorescein reporter molecule
Roche four-in-one molecular test for SARS-CoV-2, Influenza A/B viruses and RSV receives U.S. FDA Emergency Use Authorization
The PTR3-TOF 10K is a new generation of ultimate performance PTR-TOF systems optimized for the detection of highly-oxygenated organic molecules and RO2 radicals.
Process up to 15L/day of ultra-pure water with the compact and reliable Thermo Scientific™ Barnstead™ MicroPure™ Water Purification System. This system is an outstanding choice for applications such as HPLC or other instrumental analyses, sample preparation, glassware rinsing or molecular biology work in which endotoxins and/or nucleases would interfere.
The Waters Regulated Bioanalysis Platform Solution with UNIFI®is a single-vendor solution for bioanalytical laboratories to generate quantitative results while maintaining optimal productivity, quality and consistency to maximize up-time and cost per sample.The UNIFI Scientific Information System is designed to accelerate your capabilities and anticipate your imperatives. The platform enhances your ability to develop robust m…