Ghost-Buster column

Welch Materials, Inc487Available: Worldwide

In HPLC analysis, especially in gradient elution, some unexpected peaks, which are usually called Ghost peaks, may appear in a chromatogram. Ghost peaks my appear for many reasons, including residual in injection valve, water pollution impurities and unknown components in sample. Generally, they are caused by impurities from mobile phase. Welch Ghost-Buster Column can solve this problem easily! Welch Ghost-Buster colu…

Welch Materials, Inc

The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our  Product Directory.

Average Rating 5.0

|3Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

Absolutely great in helping the chromatographers.

 

Average Rating 5.0

Application Area:

Small molecules

It gave unexpected result where I tried a lot to get a good S/N ratio for a peak in a chromatography with positive drift. But Welch Ghost buster helped me with a clean baseline to get through the problem. Now it is easily giving the expected results.

Review Date: 5 Mar 2022 | Welch Materials, Inc

Fantastic results. Saved a lot of time.

 

Average Rating 5.0

Application Area:

Small molecules

Ghost Buster column has really worked out, helped me to eliminate organic and UV absorbing impurities in HPLC method development and methods are free from noise and very reproducible.

Review Date: 27 Jul 2021 | Welch Materials, Inc

Very innovative and problem solving product!

 

Average Rating 5.0

Application Area:

Method Development

In HPLC/UPLC, methods in which mobile phase is run in the form of a binary gradient, it is seen in many cases that ghost peaks appear in the baseline which interfere with analytes and sometimes with main peak. These arise due to impurities in solvents i.e. mobile phase. It is suspected by scientist that it is because the needle is not clean. However, while developing a method I saw that a ghost peak appeared on some columns exactly at the retention time of my main peak. Surprisingly, this did not happen with one of the columns which confirmed that the ghost peak was not related to needle contamination. However, after attaching a separate ghost column between pump and the injector (your injected sample does not pass through it but only mobile phase passes through it) the ghost peak simply disappeared. Moreover, the humps in the mobile phase got greatly reduced making the peaks of interest quantifiable with ease. In the past, I faced this problem of ghost peaks appearing at the same retention time as my main peak, impacting the area of diluted standard in the impurity method and also putting a question mark on the specificity of the method. But after using ghost column, this problem is totally solved! It would have been better had I come to know this solution earlier. However, this technology is recent development. An amazing product!

Review Date: 11 Feb 2020 | Welch Materials, Inc

In HPLC analysis, especially in gradient elution, some unexpected peaks, which are usually called Ghost peaks, may appear in a chromatogram.

Ghost peaks my appear for many reasons, including residual in injection valve, water pollution impurities and unknown components in sample. Generally, they are caused by impurities from mobile phase.

Welch Ghost-Buster Column can solve this problem easily!

Welch Ghost-Buster column can efficiently adsorb and remove the impurities from mobile phase to eliminate their interference to the target peaks. Installed between the gradient mixer and the sampler, Ghost-Buster column can trap most ghost peaks before HPLC analysis.