Products & ReviewSeparations

SupelMIP® SPE - Bisphenol A

Sigma-Aldrich Supelco54277-UAvailable: Worldwide

The SupelMIP SPE line consist s of highly cross-linked polymers that are engineered to extract a single analyte of interest or a class of structurally related analytes with an extremely high degree of selectivity. This is possible because selectivity is introduced during MIP synthesis in which a template molecule, designed to mimic the analyte, guides the formation of specific cavities or imprints that are sterically and chemi…

Sigma-Aldrich Supelco

The supplier does not provide quotations for this product through SelectScience. You can search for similar products in our  Product Directory.

Average Rating 4.2

|2Scientists have reviewed this product

Ease of Use
After Sales Service
Value for Money
Write your own review

High purity

 

Average Rating 5.0

Application Area:

Assay

I have analyzed bisphenol in drinking water bottles.

Review Date: 23 May 2022 | Sigma-Aldrich Supelco

Still need more trials.

 

Average Rating 3.3

Application Area:

Water sample from drinking bottles

Not too successful, did not concentrate enough to be detected via GC-MS. Need to adjust the priming and elution.

Review Date: 25 Oct 2018 | Sigma-Aldrich Supelco

The SupelMIP SPE line consist s of highly cross-linked polymers that are engineered to extract a single analyte of interest or a class of structurally related analytes with an extremely high degree of selectivity. This is possible because selectivity is introduced during MIP synthesis in which a template molecule, designed to mimic the analyte, guides the formation of specific cavities or imprints that are sterically and chemically complementary to the analyte(s) of interest.

By careful design of the imprinting site, either by molecular modeling, experimental design, or screening methods, the binding cavities can be engineered to offer multiple interaction points with the analyte(s) of interest. This leads to a stronger interaction between the solid-phase and the analyte(s). As a consequence, harsher wash conditions can be tolerated during SPE methodology resulting in cleaner extracts. Because extraction selectivity is significantly improved, lower background is observed allowing analysts to achieve lower limits of detection.

Features and Benefits:

  • Highly selective SPE for trace analysis in complex matrices
  • Achieve lower detection limits
  • Significant time and cost savings
  • Improved MS-compatibility

Product Overview

Links