Thermo Scientific™ Acclaim™ 120 C18 Reversed-Phase LC Column
High Performance Reversed-Phase Columns for the Separation of Small Molecules. The Acclaim® 120 columns are designed for high resolution reversed-phase separations. The very high surface coverage and very low metal content together result in columns with excellent efficiencies. These columns provide exceptional performance for a variety of applications in the pharmaceutical, chemical, environmental, and food separations areas.…
Analyze the human plasma samples
Column shows stable results in many runs; Easy to use.
Review Date: 1 Apr 2022 | Thermo Fisher Scientific
Analysis of wide verity of applications like environmental sciences and chemical analysis for separa
Acclaim C18 columns are HPLC (high performance liquid chromatography) columns that use a C18 substance as the stationary phase. Acclaim C18 HPLC columns are used in environmental sciences and chemical analysis, as well as industries such as pharmaceutical and environmental sciences, to analyze individual parts of chemical mixtures
Review Date: 30 Mar 2022 | Thermo Fisher Scientific
Development of analytical method
High performance reversed-phase columns for the separation of small molecules, can separate better than other columns. This column helps me a lot in my development of pharmaceutical products.
Review Date: 7 Jun 2021 | Thermo Fisher Scientific
One of the best columns available.
Review Date: 20 Sept 2011 | Thermo Fisher Scientific
High Performance Reversed-Phase Columns for the Separation of Small Molecules.
The Acclaim® 120 columns are designed for high resolution reversed-phase separations. The very high surface coverage and very low metal content together result in columns with excellent efficiencies. These columns provide exceptional performance for a variety of applications in the pharmaceutical, chemical, environmental, and food separations areas.
Acclaim 120 C18 columns have high surface coverage, resulting in high-capacity columns. They are stable between pH 2 and 8 and available in 3 and 5 μm particles sizes, and 4.6, 3.0, and 2.1 mm-diameters, with an average pore diameter of 120 Å. Acclaim 120 C18 is also available in 2.2µm RSLC format (see Acclaim Rapid Separation LC columns section for more details). All phases are LC/MS compatible because of the low silica bleed that results from the stable bonding procedure.
Acclaim® 120 C18 Reversed-Phase LC Column Features:
- Ultrapure silica with high-density bonding for low silanol activity
- Very high efficiencies for maximum resolution
- Reproducible manufacturing practices for reproducible column-to-column performance
- LC/MS compatible
Column Details:
- Particle Size: 3, 5 µm
- Pore Size: 120 Å
- Length: 50, 100, 150, 250 mm
- ID: 2.1, 3.0, 4.6 mm