Selected Filters:

Titan™ C18 UHPLC Columns, 1.9 μm

Sigma-Aldrich Supelco

Titan UHPLC columns, based on 1.9 µm totally porous monodisperse silica, outperform other UHPLC columns. These UHPLC columns provide the performance scientists expect (typically > 250,000 N/m), but at a greatly reduced cost. With the narrowest particle size distribution of all available sub-2 µm porous particles, Titan columns are the outcome of the highly efficient patent pending Ecoporous™ silica manufacturing process tha…

5.0/5.0
|1 Review

Supel™ QuE Empty Centrifuge Tube with Lid

Sigma-Aldrich Supelco

“QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) - Supel™ QuEEmpty Centrifuge Tube with Lid, centrifuge tube volume 50 mL, pk of 50, suitable for EN 15662:2008 per BSDispersive SPE (dSPE), often referred to as the "QuEChERS" method, is an emerging sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. In dSPE, food/agricultural…

4.9/5.0
|2 Reviews

SP-2560 Capillary GC Column

Sigma-Aldrich Supelco

SP-2560 Capillary GC Column• Application: This highly polar biscyanopropyl column was specifically designed for detailed separation of geometricpositional (cis/trans) isomers of fatty acid methyl esters (FAMEs). It is extremely effective for FAME isomer applications.• USP Code: This column meets USP G5 requirements.• Phase: Non-bonded; poly(biscyanopropyl siloxane)• Temp. Limits: Subambient to 250 °C (isothermal or programmed

5.0/5.0
|1 Review

Polydimethylsiloxane/Divinylbenzene (PDMS/DVB) SPME Fibers

Sigma-Aldrich Supelco

Polydimethylsiloxane/Divinylbenzene (PDMS/DVB) SPME Fibers.Solid Phase Microextraction (SPME) is an innovative, solvent-free sample prep technology that is fast, economical, and versatile. SPME uses a fiber coated with a liquid (polymer), a solid (sorbent), or a combination of both. The fiber coating removes the compounds from your sample by absorption in the case of liquid coatings or adsorbtion in the case of solid coatings.…

4.5/5.0
|2 Reviews

Polydimethylsiloxane (PDMS)- non-polar SPME Fibers

Sigma-Aldrich Supelco

Polydimethylsiloxane (PDMS)- non-polar SPME Fibers.Solid Phase Microextraction (SPME) is an innovative, solvent-free sample prep technology that is fast, economical, and versatile. SPME uses a fiber coated with a liquid (polymer), a solid (sorbent), or a combination of both. The fiber coating removes the compounds from your sample by absorption in the case of liquid coatings or adsorbtion in the case of solid coatings. The S…

4.9/5.0
|2 Reviews

Ascentis® Express RP-Amide HPLC Columns

Sigma-Aldrich Supelco

Ascentis Express RP-Amide HPLC columns are the most recent product additions to the Supelco HPLC product line. Combining an embedded polar group (EPG) stationary phase with the Fused-Core particles, Ascentis Express RP-Amide provides a host of useful benefits to the HPLC chromatographer.   Ascentis Express RP-Amide is a blend of modern phase technology and innovative particle technology. The Fused-Core particle provides…

4.7/5.0
|1 Review

Ascentis® Express C18

Sigma-Aldrich Supelco

C18 HPLC column for High Speed and High Resolution Applications. Ascentis® Express C18 is the first choice for starting a new method. Ascentis Express HPLC columns, through the use of Fused-Core® particle technology, can provide you with both the high speed and high efficiencies of sub-2 μm particles at lower system pressure. With identical conditions, the Ascentis Express C18 column performs more than 4X faster tha…

4.9/5.0
|3 Reviews

Discovery C18 HPLC Columns

Sigma-Aldrich Supelco

Classic reversed-phases for all general-purpose applications. Features: Excellent peak shape and efficiency compared to competitive columns Classic reversed-phase retention and selectivity Excellent, no-bleed character for LC-MS applications C18 is generally more retentive than the C8 Column Details: Chemistry: C18 Particle Size: 5 µm Pore Size: 180 Å Length: 20, 30, 50, 100, 125, 150, 250 mm ID: 2.1, 3.0, 4.…

5.0/5.0
|1 Review

Discovery® BIO Wide Pore C18 HPLC Column

Sigma-Aldrich Supelco

Peptide maps generated by RP-HPLC provide valuable information about protein structure, stability, and purity. To be effective, the RP-HPLC column must be able to resolve a high percentage of the peptides in the sample. The more peptides, the better the information. Discovery BIO Wide Pore C18 gives unsurpassed RP-HPLC resolution of peptide maps from enzymatic digests. The improvements in silica and bonded-phase chemistry we h…

5.0/5.0
|1 Review

SLB®-IL111 Capillary GC Column

Sigma-Aldrich Supelco

SLB®-IL111 Capillary GC Column for FAME and Petroleum Applications. World’s first commercial column to rate over 100 on our GC column polarity scale. Selectivity most orthogonal to non-polar and intermediate polar phases, resulting in very unique elution patterns. Maximum temperature of 270 ºC is very impressive for such an extremely polar column. Great choice for separation of polarizable analytes (contain double and/or tripl…

4.0/5.0
|1 Review

SLB-5ms Capillary GC Column

Sigma-Aldrich Supelco

SLB-5ms Capillary GC Column Application: The 5% phenyl equivalent phase provides a boiling point elution order with a slight increase in selectivity, especially for aromatic compounds. The low bleed characteristics, inertness, and durable nature make it the column of choice for environmental analytes (such as semivolatiles, pesticides, PCBs, and herbicides) or anywhere a low bleed non-polar column is required. USP Code: Th…

3.7/5.0
|1 Review

SupelMIP® SPE - Bisphenol A

Sigma-Aldrich Supelco

The SupelMIP SPE line consist s of highly cross-linked polymers that are engineered to extract a single analyte of interest or a class of structurally related analytes with an extremely high degree of selectivity. This is possible because selectivity is introduced during MIP synthesis in which a template molecule, designed to mimic the analyte, guides the formation of specific cavities or imprints that are sterically and chemi…

4.2/5.0
|2 Reviews


Ascentis® C18 HPLC column, 3micron, 15cm L x 4.6mm ID

Sigma-Aldrich Supelco

The Ascentis family of columns is the fourth generation of HPLC column technology from Supelco scientists. Ascentis columns are bonded on high purity, 100 Angstrom silica including 3, 5, and 10 micron particle size. Columns are designed for small molecule applications and are scalable from micro columns (1.0 mm I.D.) to preparative dimensions (50 mm I.D.). The family includes C18, C8, Phenyl, Si and embedded polar group phase,…

4.0/5.0
|9 Reviews

Supel™ QuE PSA/C18 Tube

Sigma-Aldrich Supelco

“QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) - Supel™ QuEPSA/C18 Tube, pack of 100, suitable for 2007.01 per AOACDispersive SPE (dSPE), often referred to as the "QuEChERS" method, is an emerging sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. In dSPE, food/agricultural samples are first extracted with aqueous miscibl…

3.3/5.0
|1 Review


Carbon nanohorns, as-grown

Sigma-Aldrich Supelco

Single-walled carbon nanohorns are made of graphene sheets with long cone-shaped tips with the diameters of 2-5 nm and the length of 40-50 nm. Thousands of carbon nanohorns form spherical aggregates of about 100 nm in diameter.

2.3/5.0
|1 Review

Supel™ Tox SPE Cartridges

Sigma-Aldrich Supelco

Fast and Simple Cleanup for Mycotoxin Analysis.The need for a quick, simplistic sample cleanup approach prior to chromatographic mycotoxin analysis has brought about SPE cartridges that significantly decrease sample prep time, increase reproducibility, and are more user friendly as compared to the industry standard immunoaffinity columns. In addition the Supel Tox SPE approach requires less equipment and fewer consumables.Unli…

0.0/5.0
|0 Reviews

SPME-Fast Fit Fiber Assemblies (FFA)

Sigma-Aldrich Supelco

A new generation of SPME products.The Fast Fit Fiber Assemblies were developed by Chromline srl Prato Italy in cooperation with Supelco expanding the applicability of SPME for rapid sampling and analysis using multiple fiber assemblies. This product line is centered around the barcoded SPME Fast Fit Assemblies that can be automatically exchanged on a CTC CombiPAL type autosampler equipped with the Multi Fiber EXchanger (MFX) s…

0.0/5.0
|0 Reviews

BIOshell™ A160 Peptide C18, 2.7 μm HPLC Columns

Sigma-Aldrich Supelco

BIOshell™ A160 Peptide C18, 2.7 μm HPLC Columns BIOshell A160 Peptide C18 columns packed with 2.7 μm particles, 160 Å pores, are as efficient as sub-2-μm porous particles, but at ½ the backpressure.These columns can be operated long term at pressures up to 600 bar (60 MPa or 8500 psi), temperatures up to 90 °C and within the pH range of 1 to 8. BIOshell A160 Peptide C18 columns can be run on all HPLC systems including UHPLC s…

0.0/5.0
|0 Reviews

Supel™ QuE PSA Tube

Sigma-Aldrich Supelco

“QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) - Supel™ QuE PSA Tube, pk of 50, suitable for EN 15662:2008 per BSDispersive SPE (dSPE), often referred to as the "QuEChERS" method, is an emerging sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. In dSPE, food/agricultural samples are first extracted with aqueous miscible…

0.0/5.0
|0 Reviews

Supel™ QuE Acetate Tube

Sigma-Aldrich Supelco

"QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) - Supel™ QuE Acetate Tube, pk of 50, suitable for 2007.01 per AOACDispersive SPE (dSPE), often referred to as the "QuEChERS" method, is an emerging sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. In dSPE, food/agricultural samples are first extracted with aqueous miscible…

0.0/5.0
|0 Reviews

Supel™ QuE Citrate Extraction Tube

Sigma-Aldrich Supelco

"QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) - Supel™ QuE Citrate Extraction Tube, pk of 50, suitable for EN 15662:2008 per BSDispersive SPE (dSPE), often referred to as the "QuEChERS" method, is an emerging sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. In dSPE, food/agricultural samples are first extracted with aq…

0.0/5.0
|0 Reviews

SLB-IL60 Ionic Liquid GC column

Sigma-Aldrich Supelco

SLB-IL60 Ionic Liquid Capillary GC ColumnApplication: Modified (deactivated) version of SLB-IL59 provides better inertness. Selectivity more polar than PEG/wax phases, resulting in unique elution patterns. Higher maximum temperature than PEG/wax columns (300 ºC compared to 270-280 ºC). Excellent alternative to existing PEG/wax columns. Also a good GCxGC column choice. Launched in 2012.USP Code: NonePhase: Non-bonded; 1,12-Di(t…

0.0/5.0
|0 Reviews

SLB-IL59 Ionic Liquid GC Column

Sigma-Aldrich Supelco

SLB-IL59 Ionic Liquid Capillary GC Column• Application: Selectivity more polar than PEG/wax phases, resulting in unique elution patterns. Higher maximum temperature than PEG/wax columns (300 ºC compared to 270-280 ºC). Great choice for analysis of neutral and moderately basic analytes. Launched in 2009.• USP Code: None• Phase: Non-bonded; 1,12-Di(tripropylphosphonium)dodecane bis(trifluoromethylsulfonyl)imide• Temp. Limits: Su…

0.0/5.0