AP/MALDI (ng) UHR
MassTech Inc.MassTech, Inc. is proud to announce the newest member to the AP-MALDI family – the AP-MALDI (ng) UHR (Ultra High Resolution).
To uncover the crucial information for criminal investigations and legal proceedings, forensic analysts rely on sophisticated methodologies that yield objective and scientifically grounded insights. These approaches include DNA analysis, fingerprinting, ballistics, and toxicology. Explore how robust forensic analysis empowers law enforcement agencies and legal professionals to solve crimes and uphold justice.
MassTech, Inc. is proud to announce the newest member to the AP-MALDI family – the AP-MALDI (ng) UHR (Ultra High Resolution).
Automated, rapid detection and enumeration of microbial contamination based on ATP bioluminescence
The Thermo Scientific Ultra Agarose Spin Kit is an advanced system for isolating DNA from agarose gels using spin filters. The purified DNA can be used directly for any downstream application. Features • Ultra fast protocol: DNA is ready to use in 5–6 minutes • Low melting point agarose not required • Can be used for TAE and TBE gels • No specialised equipment required • DNA is eluted into sterile water or elution buffer (supp…
Thermo-Fast Electro-Fast® Gel Systems are ideal for high throughput electrophoresis of PCR products or samples containing a small number of DNA species. When used to its full capacity, the Electro-Fast® can accommodate samples from either one 96-well microplate or two microplates (using double density combs). An additional lane in each row enables a DNA marker to be loaded in addition to all the samples from each row of a 12 x…
Spark Holland has been operating at the forefront of autosampler design for 25 years. Spark’s Reliance™ autosampler is the first true bio-injector, and is preferred by customers for 4 simple reasons: - Lowest possible carry-over- High-speed wash cycles- Low maintenance- Conditioned sample storage The Reliance™ autosampler complies with GLP requirements and can be coupled with most LC-MS systems. It runs fully integra…
8 nm bandwith, Visible single beam spectrophotometer, for fast, reliable and easy measurements.
Multi lingual, 4 nm bandwith, spectrophotometer, for fast, reliable and easy measurements.
Multi lingual, 4 nm bandwith, spectrophotometer, for fast, reliable and easy measurements.
Multi lingual, 1.8 nm bandwith, spectrophotometer, for fast, reliable and easy measurements.
Can be configured to optimally deal with most varied NMR requirements. Options include: gradient-assisted spectroscopy, high resolution MAS, LC-NMR, automatic sample changers, accurate variable temperature control and high-performance rf modulators.
Fully automatic, temperature controlled refractometer. Measures refractive index, Brix
Hypersil Green columns allows for sharp, symmetrical and easily quantifiable assays to be developed quickly and easily. Product detail: Hypersil Green columns are developed for environmental analysis. The chromatographic separation of phenols, nitrophenols, chlorophenols, triazines, urea pesticides, phthalates and many other polar compounds requires a separating phase specially designed for the task. Hypersil Green ENV has…
Thermo Electron Corporation offers a full range of extraction accessories to complement both traditional column and 96-well plate technologies. These include vacuum manifolds, collection tubes and plates and method development kits.
o The benchmark in based deactivated silica columnso Sharp peaks and improved symmetry for basic compoundso Value and performance from a globally referenced column Product detail: DASH columns are packed to the same high standards as our analytical columns, and offer superioir chromatographic resolution in a design that eliminates the need for endfittings and wrenches during column change over. This makes column inst…
Fluophase RP Columns o A range of perfluorinated phases for alternative selectivityo Extra retention and selectivity for halogenated compoundso Select from 100Å and 300Å pore sizes Product detail:For alternative selectivity to traditional alkyl phases, we recommend you try the perfluorinated phases of Fluophase columns. The stationary phase of Fluophase RP contains a perfluorinated C6 chain, where every hydrogen atom on…
Hypersil 100 C8 Columns Compared to other classical materials, Hypersil 100 has a smaller pore diameter of only 100Å, which creates a higher specific surface area that can be advantageous where longer retention times are needed, such as chromatography of polar compounds. Product detail: Compared to other classical materials, Hypersil 100 has a smaller pore diameter of only 100Å, which creates a higher specific surface area…
The UNIGUARD drop-in cartridge fits both our guard systems: the stand alone UNIGUARD and the Direct Connection UNIGUARD. Product detail: We recommend all analytical columns are protected by a guard cartridge, which is replaced on a regular basis. The ID of the analytical column determines the correct ID for the guard cartridge. We offer 10x1.0, 10x2.1, 10x3.0, 10x4.0 (for use with both 4.0 and 4.6mm ID analytical columns) i…
RP-HPLC for Protein/Peptide Analysis and PurificationJupiter® HPLC columns offer optimized reversed phase solutions for protein and peptide characterization and purification. A wide variety of phases (C18, C12, C5, C4) and dimensions (capillary-preparative)/bulk media are available to support the majority of separation requirements.Jupiter 300 - 300 Å columns designed to purify intact proteinsJuptier Proteo - 90 Å columns eng…
QuickGel electrophoresis products are compact and easy-to-use, allowing cost effective manual separation without sacrificing quality of accuracy.
A unique mass analyzer combining the simplicity of MALDI, the power of MSn and accuracy and resolution of TOF for the next generation of structural analysis problems. It can be used to determine protein sequences, proteoglycans, carbohydrates, phosphorylation sites and posttranslational modifications. The AXIMA-QIT™ is designed for the structural characterization of biomolecules, not just mass measurement. It is a unique hybri…
Setting the Standard for pH Method DevelopmentRugged reversed phase HPLC columns that offer extended lifetime under extreme pH conditions and excellent stability for reproducible, high efficiency separations. Take full advantage of high and low pH conditions (pH 1-12) to manipulate selectivity Expect longer column lifetime with patented TWIN-NX™ technology Ideal for analytical and preparative separations of basic and acid…
The TV400-DGGE denaturing gradient gel electrophoresis system is a cost-effective solution for researchers studying mutations and DNA polymorphisms critical in disease aetiology and genetic diversity. Designed primarily for parallel denaturing gradient gel electrophoresis (DGGE), where electrophoresis and the denaturing gradient run in the same direction, the TV400-DGGE has a maximum 96-sample throughput compatible with standa…
The ND-8000 8-Sample UV-Vis Spectrophotometer measures 1 ul samples, up to 8 at a time. Like the popular ND-1000, the ND-8000 utilizes a patented sample retention system that eliminates the need for cuvettes and capillaries and allows for a complete measurement cycle (analyses of 8 samples and cleaning) in 30 seconds or less. In addition, the high absorbance capability eliminates the need for dilutions in most cases. For loadi…
The multiSUB Mini is the smallest unit in the multiSUB range, designed for low to medium numbers of samples. The small gel size maximises run economy but does not compromise versatility as two tray options are available – 7 x 7cm and 7 x 10cm, and combs ranging from preparative up to 16 samples. Simply by altering the gel tray or comb, this compact unit is capable of resolving up to 64 different samples, prepping 1ml of samp…
The miniRapide is a completely self contained system designed for quick checks of samples. Gel casting, running and analysis are all performed in the same ultra compact unit. Buffer and gel volumes have been kept to a minimum and the parallel electrode arrangement allows ultra efficient current transfer, enabling resolution to be completed within 30 minutes. The UV transparent base allows direct viewing on a UV Transillumina…