roQ™ QuEChERS Kits
Phenomenex IncQuick, Easy, Cheap, Effective, Rugged for multiresidue pesticide clean-up
Identification and optimization of the chemical, series of chemicals or bio-molecule that will interact with the target using impartial, expert opinion about the best equipment, services and the latest techniques
Quick, Easy, Cheap, Effective, Rugged for multiresidue pesticide clean-up
Exciton specialize in the development and manufacture of the highest quality fluorescent and absorber dyes and dye stabilisers for applications ranging from fluorescent tags, OLEDs, neon cut filters, colour gamut filters, optical recording media and telecommunications materials. Their laser dyes provide optimum lasing for a given mode of excitation with the highest photochemical stability. Exciton are leaders in the developmen…
The Echo 525 platform, like the other Echo liquid handler models, is designed to use sound energy to transfer reagents. Unlike the other Echo models, the Echo 525 platform transfers at a larger volume increment (25 nL). This enables the more rapid transfer of aqueous reagents required in biochemical and genomics assays setup.
The CambTEK Rapid Extraction System – A new approach to automated sample preparation of solid dosage forms for improved quality of data and productivity. CambTEK's Rapid Extraction System (RES) delivers a step-change in performance compared with the existing methods, and is achieved using robust technologies and an intelligent consumable. Utilizing non-invasive turbulent flow with the option of ultasonics the RES delivers many…
Powerful high-resolution benchtop MALDI-TOF MS – 15k resolution – easy to use but ideal for many analytical challenges.
BioDrop μLITE is the only choice for micro-volume measurement when you need speed without sacrificing accuracy or precision. With no moving parts, the unique in-built sample port offers unrivalled performance delivering a dsDNA detection limit of 1ng/μL. Because the pathlength doesn’t change, the instrument provides excellent measurement reproducibility. Measurements made with the BioDrop μLITE are also highly accurate becaus…
BioDrop DUO UV/Vis spectrophotometer has two measurement modes: a unique in-built sample port unrivalled dsDNA detection limit of 1ng/μl PLUS a cuvette holder for the revolutionary BioDrop CUVETTE 125, ideal for highly concentrated samples. BioDrop DUO is quick and easy to use. It has a large capacitive colour touch screen with on-board software for data acquisition and analysis. Pre-programmed methods for DNA, RNA, oligos and…
High binding surface is capable of binding medium (>10kD) and large biomolecules that possess ionic groups and/or hydrophobic regions Binding capacity is approximately 400 to 500ng IgG/cm2 Ideal for immunoassays Without lids, lids supplied separately Total volume is 360 µL; recommended working volume of 75 to 200 µL Conforms to standard microplate footprint and dimensions
Round bottom wells with 330 µL total volume Recommended working volumes of 75 to 200 µL Nonreversable lids with condensation rings to reduce contamination Treated for optimal cell attachment Sterilized by gamma radiation and certified nonpyrogenic Individual alphanumeric codes for well identification Individually wrapped
The miVac Quattro Concentrator is suitable for use with a wide range of solvents, from volatile organic solvents through to water and some of the higher boiling point solvents. The Quattro is a centrifugal vacuum concentrator compatable for use with variety of sample formats including tubes, microplates, vials and round bottom flasks. Making it an ideal "work-horse" concentrator for the busy lab. The Quattro has more than d…
UHPLC columns require less solvent, but they need the highest quality there is. Merck Millipore’s LiChrosolv® solvents are optimized for UHPLC instruments. They can substantially improve the performance of your separations, particularly in combination with our proven Purospher® STAR UHPLC and Chromolith® HPLC columns. LiChrosolv® Solvents for Liquid Chromatography Benefits: Gradient grade and hypergrade qualities are suita…
High performance, versatility and ease-of-use in a compact design for efficient mass spectrometry analysis.
Are you familiar with SiliCycle’s heterogeneous (silica-supported) catalysts? Gathered under the SiliaCat® brand, they are made using an innovative technology. The matrix consists of organically modified silica, described as a sol-gel hybrid organic-inorganic material. The SiliaCat family is an essential tool in the chemical manufacturing industry, as it opens the door for a “Green” and environmentally friendly synthetic rout…
Fast, reliable & selective. Add these features to a top grade silica gel and you will find a pre-packed flash cartridge that will allow you to achieve great peak resolutions time and time again. Therefore, if your laboratory’s high throughput demands require results that are processed quickly, SiliaSep columns are your partners for your venture.Pre-packed Flash Cartridges SiliaSep™ Features: Fast, reliable, easily reproduc…
The most popular amine-reactive biotinylation reagent for antibody labeling Thermo Scientific™ EZ-Link™ Sulfo-NHS-LC-Biotin and Labeling Kits Features: Water-soluble analog of NHS-LC-Biotin Reacts with primary amines at pH 7-9 in non-amine-containing buffers such as borate, carbonate or phosphate buffers Negative charge of -SO3 group keeps biotinylation localized at the cell surface Creates an amide bond Applicatio…
The First Real Infrared Cameras with Thermal, Visible, and MSX Imaging Starting Under $1K Now you can afford the ultimate inspection tool. Gain the competitive advantage and take care of more customers. Blow them away with dramatic MSX thermal images that clearly reveal problems from sources of energy loss, moisture intrusion and structural issues to overheating electrical and mechanical equipment.MSX adds key details from th…
The HT2000H Headspace autosampler is made to meet the needs of static headspace injection for GC analysis. HTA's proven superior headspace technology is based on a high performing gastight syringe. Through a short flow path, it eliminates any source of error, such as vial pressurization, valve switching, loop filling or transfer lines assuring repeatability (RSD up to To obtain the highest sample throughput, the progressive s…
Most demanding applications and finest integrated vacuum control capabilities. Includes leading safety standards and features for superior ease of use and reduced cost of ownership. Reduce your process times significantly by using three programs for automated distillation.Hei-VAP Precision Features: Available in hand lift or motor lift configurations Experience the advantages of our large 4.3 '' color graphic display wh…
The High-Sensitivity PTR-QMS 500 is an ultra-sensitive real-time monitor for volatile organic compounds (VOCs) and has a detection limit of < 1 pptv. The High-Sensitivity PTR-QMS 500 is the most sensitive commercial PTR-MS instrument available in the market and represents the 4th and most advanced generation of IONICON PTR-MS systems. It is the successor of the world's bestselling PTR-MS system: the IONICON High-Sensitivity P…
Titan UHPLC columns, based on 1.9 µm totally porous monodisperse silica, outperform other UHPLC columns. These UHPLC columns provide the performance scientists expect (typically > 250,000 N/m), but at a greatly reduced cost. With the narrowest particle size distribution of all available sub-2 µm porous particles, Titan columns are the outcome of the highly efficient patent pending Ecoporous™ silica manufacturing process tha…
“QuEChERS” (Quick, Easy, Cheap, Effective, Rugged, and Safe) - Supel™ QuEEmpty Centrifuge Tube with Lid, centrifuge tube volume 50 mL, pk of 50, suitable for EN 15662:2008 per BSDispersive SPE (dSPE), often referred to as the "QuEChERS" method, is an emerging sample prep technique that is becoming increasingly popular in the area of multi-residue pesticide analysis in food and agricultural products. In dSPE, food/agricultural…
SP-2560 Capillary GC Column• Application: This highly polar biscyanopropyl column was specifically designed for detailed separation of geometricpositional (cis/trans) isomers of fatty acid methyl esters (FAMEs). It is extremely effective for FAME isomer applications.• USP Code: This column meets USP G5 requirements.• Phase: Non-bonded; poly(biscyanopropyl siloxane)• Temp. Limits: Subambient to 250 °C (isothermal or programmed