SPE Cartridges Products & Reviews

25

SPE Cartridges

Product Filter

Explore by Field
Solid-Phase Extraction
SPE Cartridges
Explore by Company

Ratings

Search

Selected Filters:


Clean Screen® DAU Solid Phase Extraction Columns

UCT, Inc.

Clean Screen® DAU Solid Phase Extraction Column is the flagship product of the forensic solid phase extraction column line. The first product of its kind in the industry, it is a mixed-mode column exhibiting both hydrophobic and cation exchange characteristics. Over 20 years of experience has shown this column to be effective on hundreds of drugs in both the acid-neutral and basic drug categories.

4.6/5.0
|12 Reviews
Request Pricing

Clean Screen® XCEL Solid Phase Extraction Columns

UCT, Inc.

The Clean Screen® XCEL Solid Phase Extraction Columns are a line of sample prep phases designed to reduce the number of steps in the extraction, and therefore the amount of time and solvent necessary to complete the sample cleanup. Further advantages include reduced sample size and improved cleanliness and recovery. The Xcel I column will extract a wide array of basic drugs including benzodiazepines and opiates. The Xcel II co…

5.0/5.0
|1 Review
Request Pricing

Enviro-Clean® Universal Cartridges

UCT, Inc.

These cartridges are designed to meet large volume, real world samples. The frits and sorbent bed resist plugging, the format fits several types of manual and automated extraction systems. Various bonded phases available including C18, C8, DVB, & graphitized carbon black.

4.6/5.0
|7 Reviews
Request Pricing

Clean Screen® FASt Columns

UCT, Inc.

The Clean Screen® FASt column is a novel approach to improved sample preparation for LC/MS analysis. The column employs a one step process to prepare urine samples for analysis of multiple drugs and metabolites. By quickly and efficiently reducing the amount of unwanted matrix and particulates in the final sample, the analysis can proceed with less chance of matrix suppression and LC column clogging.

5.0/5.0
|1 Review
Request Pricing

Endcapped C18 - Enviro Clean® SPE Cartridges

UCT, Inc.

Endcapped C18 - Enviro Clean SPE Cartridges Enviro-Clean® cartridges are designed for use by analysts that demand a clean, dependable and rugged product for low level environmental analyses. Our EC SPE Cartridges run the gambit of our sorbents for every configuration you require. C18, Octadecyl Hydrophobic, 1000 mg/6 mL. Part # EEC181M6

5.0/5.0
|1 Review
Request Pricing




Strata-X-Drug Solid Phase Extraction

Phenomenex Inc

Strata-X Drug B and N Solid Phase Extraction (SPE) sorbents are designed and quality control tested for basic and neutral drugs of abuse analysis, respectively. The sorbents are QC tested using drug probes from urine samples so that you can have confidence in your results. The sorbents also do not require conditioning/equilibrating steps, saving both time and solvent.

4.6/5.0
|4 Reviews

Captiva Filter Cartridges

Agilent Technologies

Filtration is simple, versatile, and necessary to prevent clogging of HPLC columns. Captiva's unique dual depth filtration media provides complete removal of precipitated proteins and outstanding resistance to sample clogging.

5.0/5.0
|1 Review

Pre-packed Flash Cartridges SiliaSep™

SiliCycle Inc.

Fast, reliable & selective. Add these features to a top grade silica gel and you will find a pre-packed flash cartridge that will allow you to achieve great peak resolutions time and time again. Therefore, if your laboratory’s high throughput demands require results that are processed quickly, SiliaSep columns are your partners for your venture.Pre-packed Flash Cartridges SiliaSep™ Features: Fast, reliable, easily reproduc…

5.0/5.0
|1 Review

MEPS

SGE Analytical Science

MEPS (patent pending) performs the same function as SPE, namely the purification or speciation of samples, but with some significant differences: MEPS works with much smaller samples (as small as 10µL) than full scale SPE MEPS can be fully automated – the sample processing, extraction and injection steps are performed on-line using the same syringe MEPS is applicable to GC and LC Significantly reduces the volume of solvents an…

4.8/5.0
|3 Reviews

Solid Phase Extraction (SPE) Cartridges

Sorbent Technologies, Inc.

Solid Phase Extraction is a fast and efficient sample preparation technique for cleanup or concentration for analysis, HPLC, GC, TLC, UV, IR and an excellent tool for method development. Ultra-high performance Chromabond SPE Cartridges are available in polypropylene (standard & LV) and glass tubes from 1 to 70ml sizes precision packed with a wide array of sorbents: SiOH, Alumina (A, B,N), C18, C8, C4, C2, Cyclohexyl, Phenyl, N…

4.0/5.0
|1 Review

Bond Elut Empty SPE Cartridges

Agilent Technologies

A variety of empty reservoirs is available to increase the sample capacity of Bond Elut extraction cartridges. These tubes can also be used to pack custom SPE cartridges with bulk Bondesil sorbents or other desired sorbent. They are available from 1 to 60 mL. 

4.0/5.0
|1 Review

SupelMIP® SPE - Bisphenol A

Sigma-Aldrich Supelco

The SupelMIP SPE line consist s of highly cross-linked polymers that are engineered to extract a single analyte of interest or a class of structurally related analytes with an extremely high degree of selectivity. This is possible because selectivity is introduced during MIP synthesis in which a template molecule, designed to mimic the analyte, guides the formation of specific cavities or imprints that are sterically and chemi…

4.2/5.0
|2 Reviews



InertSep Stacked SPE for PFAS

GL Sciences, Inc.

EPA Method 1633 efficiently determines PFAS in complex samples. InertSep, a line of solid-phase extraction cartridges, is known for high purity, consistency, and quality. InertSep WAX FF and GCB offer high recovery rates and cleanup efficiencies for PFAS in water, soil, food, and other complex matrices. InertSep GCB, packed with Graphite Carbon Black, is ideal for LC/MS analysis due to its excellent cleanup efficiency.

0.0/5.0
|0 Reviews
Request Pricing


Supel™ Swift HLB SPE Cartridges

Merck

Supel™ Swift HLB is a polymeric stationary phase for solid phase extraction (SPE) prior to instrumental analysis. It has both hydrophilic and lipophilic functional groups for the extraction of a broad range of compounds from aqueous samples. It retains analytes having diff erent polarities and Log P values due to its hydrophilic and lipophilic balance (HLB) property.

0.0/5.0
|0 Reviews
Request Pricing

DisQuE Dispersive Sample Preparation Kit

Waters

DisQuE Dispersive Sample Preparation is a well proven, high throughput sample preparation method for a wide array of pesticides in produce. The kit contains conveniently packaged vials with pre-measured sorbents and buffers used to provide extraction and clean-up for up to 100 samples. Each 50 mL DisQuE Extraction tube contains 6 grams of magnesium sulphate and 1.5 grams of sodium acetate. Each 2 mL DisQuE Clean-Up tube cont…

0.0/5.0
|0 Reviews



Zero-Blank Air Filter (ECBLANK)

UCT, Inc.

Airborne laboratory contamination may interfere with solid-phase extraction results. This problem is easily prevented by using the Zero-Blank filter. Using an adaptor (included), this cartridge is fitted on top of the SPE cartridge during the drying step and captures potential contamination making results more accurate.

0.0/5.0
|0 Reviews
Request Pricing