Thermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer
Test new limits of detection, characterization and quantitation with the latest Tribrid™ mass spectrometer. The Thermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer is designed to expand performance in advanced proteomics, biopharma and metabolomics applications, including quantitation using isobaric tags, low level PTM analysis, data independent acquisition (DIA), and top down proteomics. The new instrumen…
Proteomics
We receive high quality results with the instrument but the software is a bit confusing to use. I wish the instrument worked with Chromeleon. Xcaliber has too many different nodes to wade through. I also wish the calibration would last longer so we didn't have to calibrate every week.
Review Date: 12 Dec 2022 | Thermo Fisher Scientific
Proteomics
The product works well for our mass spec based protein footprinting. Customer service is top tier and the ease of use is appreciated.
Review Date: 15 Mar 2022 | Thermo Fisher Scientific
Proteomics
This is high res and high sensitive instrument. I have used it for deep proteome profiling, low abundant antigen peptide identification, low abundant protein identification in high-background matrix such as CSF, MS3 quantification.
Review Date: 28 Oct 2021 | Thermo Fisher Scientific
Complex protein characterization
This is the best mass spec on the market.
Review Date: 26 Jul 2021 | Thermo Fisher Scientific
Proteomics and metabolomics
Orbitrap Fusion is the best instrument for proteomics and metabolomics studies, it gives me high quality and reproducible results. It is user friendly, easy to handle, data acquisition software is very easy to use. Rating for ease of use is worth five stars, after sales care within servicing period is good but after service period over it is a little bit careless about servicing the instrument, Value for money is very costly so most of research centers unable to buy this instrument.
Review Date: 24 Jul 2021 | Thermo Fisher Scientific
Proteomics
Incomparable resolution for analysis of very complex samples.
Review Date: 15 Jul 2021 | Thermo Fisher Scientific
Biological research, proteomics, metabolomics and biopharma
This new platform incorporates a brighter ion source, segmented quadrupole, improved ion transmission, and improved ETD performance. Fusion Lumos technology excels at the most challenging applications, including low-level PTM analysis, multiplexed relative quantitation using isobaric tags, intact protein characterization, as well as MSn analysis of small molecules.
Review Date: 7 Apr 2021 | Thermo Fisher Scientific
Research
Best for your cost.
Review Date: 21 Mar 2021 | Thermo Fisher Scientific
Analyze organic and inorganic samples
The service is very effective and powerful. The product is very easy to apply in various fields.
Review Date: 20 Mar 2021 | Thermo Fisher Scientific
Analysis OF Cement, Clinker and Raw material samples
Chemical analysis of cement to find out the quality of cement as well as to identify the exact applications for a specific cement type. Using for chemical analysis regularly in our cement manufacturing units for cement quality control, to test quarry sites, and assess intermediate products.
Review Date: 20 Mar 2021 | Thermo Fisher Scientific
Test new limits of detection, characterization and quantitation with the latest Tribrid™ mass spectrometer.
The Thermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer is designed to expand performance in advanced proteomics, biopharma and metabolomics applications, including quantitation using isobaric tags, low level PTM analysis, data independent acquisition (DIA), and top down proteomics. The new instrument features enhanced sensitivity resulting in improved analyte detection, characterization and quantitation, enabling scientists to perform more comprehensive sample analyses faster and with better accuracy than ever before.
Novel Orbitrap Fusion Lumos MS Features:
- Novel high-sensitivity API interface combines a High Capacity Transfer Tube and an Electrodynamic Ion Funnel for increased ion flux and lower limits of detection
- Advanced Active Beam Guide prevents neutrals and high velocity clusters from entering the resolving quadrupole
- Advanced Quadrupole Technology combines high selectivity and efficiency of transfer for selected ions symmetrically across the isolation window
- Advanced Vacuum Technology improves transmission of high molecular weight ions to the Orbitrap analyzer
- Novel ETD HD—high dynamic range ETD provides significantly increased fragment ion coverage
Established Tribrid MS Features:
- Tribrid architecture — includes quadrupole mass filter, linear ion trap and Orbitrap mass analyzers
- Ultrahigh resolving power up to 500,000 FWHM, with isotopic fidelity up to 240,000 FWHM at m/z 200
- Acquisition rates of up to 20 Hz for both Orbitrap and linear ion trap MSn analyses
- Full parallelization of MS and MSn analyses with intelligent ADAPT™ (All Dynamically Available Parallelizable Time) technology
- Synchronous Precursor Selection (SPS) for MS and MSn experiments significantly increases the number of peptides and proteins identified and improves quantitative accuracy when using isobaric mass tags
- Flexibility of fragmentation — CID, HCD and optional ETD and EThcD available at any stage of MSn with detection in either the Orbitrap or linear ion trap detector enables detailed structure determination of metabolites, glycans and other small molecules
- Universal Method provides maximal peptide identifications without method optimization for samples of unknown concentration, reducing sample and instrument time requirements for routine peptide identifi cation experiments
- Intuitive and flexible drag-and-drop user interface simplifies method development and enables unique and complex workflows