Pressurized 1 Liter Reservoir- w/ bracket, fittings and tube
AutoMate Scientific Inc.Ringstand-mounted HDPE round reservoir. Includes short thumbscrew. Requires AutoMate Scientific Pressurized Perfusion System or pressure source.
Ringstand-mounted HDPE round reservoir. Includes short thumbscrew. Requires AutoMate Scientific Pressurized Perfusion System or pressure source.
Disposable hospital IV flow controller with 1/8" i.d. tubing. Useful for matching perfusion inflow rate to outflow rate.
0-10 psi precision pressure regulator and pressurized 35ml syringe holder.For anyone who needs: * Faster liquid-switching * Steady flow rate * Microinjecting * Fine microliter delivery * Small pipette delivery Can be added to any new or existing perfusion rig - from AutoMate Scientific, any third-party manufacturer, even homemade.Connect to house air or a compressor (30 to 100 psi).Stainless steel construction i…
0-10 psi precision pressure regulator and pressurized syringe holder.For anyone who needs: * Faster liquid-switching * Steady flow rate * Microinjecting * Fine microliter delivery * Small pipette delivery Can be added to any new or existing perfusion rig - from AutoMate Scientific, any third-party manufacturer, even homemade.Connect to house air or a compressor (30 to 100 psi).Stainless steel construction includ…
Bubbles in perfusion systems are caused by solution temperature changes. As solutions warm, they cannot hold as much gas, so they off-gas. This forms bubbles in perfusion tubing. It is especially true in inline heaters where the temperature rises dramatically. The best cure for bubbles is to pre-warm your solutions. AutoMate Scientific introduces the BubbleStop™ Syringe Heater with integrated temperature sensor and feedback. S…
* Consistent resultsSteady gravity-fed delivery of buffer and fixative results in complete perfusion. * Easy to set up, use and cleanComplete system with everything down to the needles. Fits in standard hoods. * Fraction of the cost of a peristaltic pump and more reliable AutoMate Scientific is providing an option for the scientist who would rather do science than design a system, source parts, phone, buy, etc. Let us take the…
* Consistent resultsSteady gravity-fed delivery of buffer and fixative results in complete perfusion. * Easy to set up, use and cleanComplete system with everything down to the needles. Fits in standard hoods. * Fraction of the cost of a peristaltic pump and more reliable AutoMate Scientific is providing an option for the scientist who would rather do science than design a system, source parts, phone, buy, etc. Let us take the…
* Consistent resultsSteady gravity-fed delivery of buffer and fixative results in complete perfusion. * Easy to set up, use and cleanComplete system with everything down to the needles. Fits in standard hoods. * Fraction of the cost of a peristaltic pump and more reliable AutoMate Scientific is providing an option for the scientist who would rather do science than design a system, source parts, phone, buy, etc. Let us take the…
Perfusion System for real-time or pre-programmed liquid switching in perfusion, physiology, biophysics, electrochemistry, or general liquid-handling research applicationsIncrease reproducibility with 10 millisecond accuracyStand-alone design - no computer necessaryRun experiments automatically - even unattendedMicroprocessor-based for accuracy and flexibilityBecause they lack a microprocessor, competing valve controllers do no…
Perfusion System for real-time or pre-programmed liquid switching in perfusion, physiology, biophysics, electrochemistry, or general liquid-handling research applicationsIncrease reproducibility with 10 millisecond accuracyStand-alone design - no computer necessaryRun experiments automatically - even unattendedMicroprocessor-based for accuracy and flexibilityBecause they lack a microprocessor, competing valve controllers do no…
Perfusion System for real-time or pre-programmed liquid switching in perfusion, physiology, biophysics, electrochemistry, or general liquid-handling research applicationsIncrease reproducibility with 20 millisecond accuracyStand-alone design - no computer necessaryRun experiments automatically - even unattendedMicroprocessor-based for accuracy and flexibilityBecause they lack a microprocessor, competing valve controllers do no…
Perfusion System for real-time or pre-programmed liquid switching in perfusion, physiology, biophysics, electrochemistry, or general liquid-handling research applicationsIncrease reproducibility with 1 millisecond accuracyValveGuard™ technology detects bad valvesPrevent damage to your ValveLink and easily observe problem valves.Run experiments automatically - even unattendedMicroprocessor-based for accuracy and flexibilityBeca…
Perfusion System for real-time or pre-programmed liquid switching in perfusion, physiology, biophysics, electrochemistry, or general liquid-handling research applicationsIncrease reproducibility with 5-10 millisecond accuracyValveGuard™ technology detects bad valvesPrevent damage to your ValveLink and easily observe problem valves.Run experiments automatically - even unattendedMicroprocessor-based for accuracy and flexibilityB…
Perfusion System for real-time or pre-programmed liquid switching in perfusion, physiology, biophysics, electrochemistry, or general liquid-handling research applicationsIncrease reproducibility with 1 millisecond accuracyValveGuard™ technology detects bad valvesPrevent damage to your ValveLink and easily observe problem valves.Run experiments automatically - even unattendedMicroprocessor-based for accuracy and flexibilityBeca…
Perfusion System for real-time or pre-programmed liquid switching in perfusion, physiology, biophysics, electrochemistry, or general liquid-handling research applicationsIncrease reproducibility with 1.5 to 4 millisecond accuracyValveGuard™ technology detects bad valvesPrevent damage to your ValveLink and easily observe problem valves.Run experiments automatically - even unattendedMicroprocessor-based for accuracy and flexibil…
Perfusion System for real-time or pre-programmed liquid switching in perfusion, physiology, biophysics, electrochemistry, or general liquid-handling research applicationsIncrease reproducibility with 20 millisecond accuracyValveGuard™ technology detects bad valvesPrevent damage to your ValveLink and easily observe problem valves.Run experiments automatically - even unattendedMicroprocessor-based for accuracy and flexibilityBec…
MED64 Mobius software is a data acquisition and analysis package for the MED64 multi-electrode array system with an abundant set of analysis functions available both online and offline. It is designed to be easy for beginners and powerful for advanced users. Mobius comes in various packages including “Evoked Potential Measurements” and “Spike Sorter” as well as a combined package.Mobius is flexible software consisting of vario…
• Biological acute or culture preparations are placed directly into the MED64 multi-electrode array probe.• The MED64 probe allows users to stimulate and record samples using 64 planar microelectrodes in an 8 x 8 array embedded in the center of a transparent glass plate.• Arrays are available in four different inter-electrode spacings; 100, 150, 300 and 450 µm enabling measurements of fine detail from small regions to larger s…
Bandwidth of 0.1Hz -10 kHz allows users to record several types of extracellular potentials. • Low-cut filter (High pass filter) with 0.1, 1, 10, and 100Hz cutoff. • High cut filter (Low pass filter) with 1, 2.5, 5, 7.5, and 10kHz cutoff. • Built-in 2-channel stimulator allows users to program and deliver complex stimulation sequences independently through any 2 electrodes. • USB connection to computer.SpecificationsHead Ampl…
Computer-controlled microelectrode current-clamp and voltage-clamp amplifier, useful for a wide range of intracellular microelectrode recording techniques with several modes of operation: two independent current clamp amplifiers with bridge balance, two-electrode voltage clamp, discontinuous current clamp, discontinuous single-electrode voltage clamp, and high-voltage current clamp. Axoclamp 900A is shipped with the following…
Premier patch-clamp amplifier for all patch-clamp configurations, with capacitive-feedback and cooling in the headstage for ultra-low noise single-channel recordings. Axopatch 200B is shipped with the following,o Axopatch 200B amplifiero CV-203BU headstage (Part number 1-CV 203BU)o US Power cord (Part number 1-3010-0011)o European power cord, CEE7/7 (Part number 1-3010-0013)o Accessory kit (Part number1-2050-0301) containing:…
Finally, a culture dish system specifically designed for live-cell microscopy! Now you can have accurate temperature control and high numeric aperture compatibility in a convenient disposable culture dish system compatible with all modes of microscopy. Never before has there been so many capabilities integrated into a specimen control system. • Easily adapted to a variety of specimen types from monolayered adherent cells to t…
Chamber, Controller, 5 Microaqueduct slides, 30 piece gasket set, 50 - #1.5 coverslips. The Objective Heater and Objective Heater Controller is optional (needed for use of high numeric aperture objectives). The objective heater is mounted to the upper end of the central retracting tube of the objective. The standard size fits diameters between 17 and 28mm. The medium size fits diameters between 23 and 29mm. There is also a la…
Culturing Cylinders are used to barricade cells or suspended specimens in a Delta T® Culture Dish or to restrict and concentrate the growth and location of cells plated on an FCS2® Coverslip. They are 5mm high and available in a variety of inside diameters including 1mm, 2mm, 4mm, 6mm, 8mm, 10mm, and 12mm. The outer diameter is always 2mm greater than the inside diameter due to the 1mm wall thickness. The cylinders are made of…
To eliminate the heat loss from the specimen, Bioptechs developed a patented Objective Heater System®, which includes a heater/sensor and an electronic controller specifically designed for this purpose. The heater/sensor is comprised of an adjustable thin-film heating band which surrounds 3/4 of the diameter of the upper region of the central retracting tube of the objective. A temperature probe positioned in the gap formed be…