Collagen, Type I solution from rat tail
Merck KGaA, Darmstadt, GermanyBioReagent, suitable for cell culture, sterile-filtered
BioReagent, suitable for cell culture, sterile-filtered
Used for cell and subcellular organelle isolation
The GD/X filter contains a unique prefiltration stack of 100% borosilicate glass.
Water in public and private swimming pools must be disinfecting to kill bacteria and viruses. Chlorine-containing preparations or even chlorine gas itself are usually used for this purpose. To check the content of chlorine and the pH value is essential.
The Spectroquant® analysis system includes photometers with cell tests and reagent tests which can be identified by barcodes pre-diluted standard solutions in various concentrations for increased reliability requirements residue-free cleaning agents Three-stage concept for internal controls Photometer Check - AQA 1 Easy to perform with certified color standards and/or Certipur® UV/VIS standards. System Check - AQA 2 R…
Uvasol® solvents from Merck Millipore are specially designed for spectroscopy and other applications that demand solvents of the highest purity. By avoiding trace contamination, they prevent misinterpretation of your results caused by traces of ultraviolet (UV), infrared (IR) and fluorescence active contamination and eliminate the need for repeat analyses. Accurate analytical results and minimal risk of misinterpretation d…
The MAS-100 CG Ex® is the only microbial air sampler that enables you to test compressed gases in Zone 2 explosion hazard areas – safe, easy and accurate. Active air sampling is reliable and safe method for identifying microbial contamination in compressed gases. At numerous points in production compressed gases can come into contact with a product. Air sampling ensures a realistic total bioburden count.Microbial contaminatio…
The Amnis NFkB translocation kit includes the conjugated antibody Anti-Hu NFkB (p50) Alexa Fluor 488, the nuclear stain 7-AAD along with the fixation solution, assay buffer and permeabilization buffer to rapidly detect and quantitate NFkB's translocation from the cytoplasm to the nucleus. Nuclear Factor kappa B (NFκB) transcription factor plays a central role in regulating many key processes in mammalian cells, including diff…
Easy, reliable and workflow-friendly bioburden testing
Powder, BioReagent, suitable for cell culture, suitable for insect cell culture, suitable for plant cell culture, ≥99%5
With 4500 mg/L glucose, L-glutamine, sodium pyruvate, and sodium bicarbonate, liquid, sterile-filtered, suitable for cell culture
Complete PCR reagent with standard Taq DNA Polymerase and inert dye
BioReagent, powder, suitable for cell culture
47 mm diameter, mixed cellulose esters (MCE) membrane, hydrophilic, white, 100 discs
Automated, rapid detection and enumeration of microbial contamination based on ATP bioluminescence
Complete range of standard solutions and rapid staining kits. Cytochemical method support. Ready-to-use products. In Vitro Diagnostic Medical Devices (IVD) registered and Community of Europe (CE) certified. Brilliant images and contrasts. Stable results with pH-buffered solutions. Panoptic methods Merck Millipore offers all standard staining solutions, such as Giemsa, Leishman, Wright or May-Grünwald,…
Merck Millipore offers a broad selection of bacteriological staining products & kits to achieve specific and sensitive staining results. Our ready-to-use kits are based on classical and modified protocols, and can be used for manual or automated staining methods. All solutions and kits are certified by the Community of Europe (CE) and the in vitro viagnostic medical devices (IVD). Products for bacteriology are produced and te…
ZIC®-HILIC HPLC columns for the separation of all classes of polar and hydrophilic compounds. What is HILIC? HILIC or Hydrophilic Interaction Liquid Chromatography is a straightforward chromatographic technique for separation of many types of polar and hydrophilic compounds. To put it simple one can say that HILIC is a normal-phase (NPLC) type of separation but uses reversed-phase (RPLC) type eluents. In HILIC one has: A c…
The base silica of Purospher® STAR columns is 99.999 % pure. Furthermore, meticulous care is given to quality control over all aspects of silica structure and chemistry. The excellent converge of the surface and the purity of the material ensures excellent peak symmetry for acidic, basic and even for chelating compounds. Accurate results with excellent peak shape for all types of analytes Outstanding resolution due…
High purity solvents for LC-MS and trace analysis with UV and fluorescence detection: 0.2 µm stainless steel filtered – perfect for use in UPLC and UHPLC. Very high UV-transmittance. Excellent baseline stability in gradient elution. Very low total ionic current (TIC) in LC-MS. Low level of ionic background and ion suppression. High ionization efficiency in all ionization methods (electrospray ionization/atmospher…
lyophilized powder, Protein ≥85 %,
NovaTaq™ Hot Start DNA Polymerase is a chemically modified form of Taq DNA polymerase that is inactive at ambient temperature.