miRNA QRT-PCR Detection Kit
Agilent TechnologiesQualified reagents for the polyadenylation of microRNAs (miRNAs) from total RNA and synthesis of first-strand cDNA from the tailed miRNAs.
Products, services, reviews and techniques used in the preliminary investigations of the disease; the cell biology, genetics and protein pathways using tissue culture, cloning and imaging.
Qualified reagents for the polyadenylation of microRNAs (miRNAs) from total RNA and synthesis of first-strand cDNA from the tailed miRNAs.
The Mx3005P system is among the most reliable and trusted QPCR instruments available, with a long record of citation in peer-review journals. The Agilent Mx3005P and Mx3000P QPCR Systems are the most flexible—and reliable—instruments available for gene expression analysis, microarray data validation, SNP genotyping, pathogen detection, DNA methylation analysis, and chromatin immuno-precipitation studies.Highly reproducible re…
Prevent unknown peaks from impacting your results Agilent MS Analyzed Vial Kits end the need to pre-test or to rerun samples due to unexpected peaks. Eliminating vials as a source of contamination translates into confidence that your results are accurate and reliable. All MS Analyzed Vials Kits include a Certificate of Analysis that contains true lot-specific and fully traceable LC/MS and GC/MS signal traces as well as criti…
The Cary 5000 is a high-performance UV-Vis and NIR spectrophotometer with superb photometric performance in the 175–3300 nm range. Using a PbSmart detector, the Cary 5000 extends its NIR range to 3300 nm making it a powerful tool for materials science research. The Cary WinUV software, a modular Windows-based software, makes it easy to perform powerful analysis and control a number of optional accessories.
The Cary 4000 is a high-end UV-Vis spectrometer with excellent photometric performance in the 175–900 nm range, making it a powerful reference spectrometer. The system is ideal for analyzing solid samples or biotechnology samples with minimal sample preparation.
The FDSS7000, the top-rated model , includes new features including 1536 dispensing tips and multiple wash tanks. The FDSS7000 continues to offer real-time kinetic analysis of various types of both nonadherent and adherent cells. The FDSS7000 offers field upgradable components including the 'FRET attachment', robotics integration, additional heads, and more allow for a customized system for you now and in the future. Features…
The basic Nucleofector® II Device is a single cuvette based system that has been used in research labs since 2001. It allows efficient transfection of hard-to-transfect cell lines and primary cells with different substrates, e.g. DNA vectors or siRNA oligonucleotides, in low throughput format. What benefits are important for your work? Efficient transfection in single cuvette format? Up to 90% efficiency with plasmid DNA…
CytoOne 35 x 10 mm TC dish, 10/sleeve, 300/case Beveled outer edges help you grasp CytoOne 35 x 10 mm dishes without accidentally displacing the lids. Tissue culture treatment promotes optimum cell attachment and growth. Growth area: 9.6 cm2; working volume: 2 ml; inner diameter: 3.5 cm. • Sturdy, flat bases resist bowing and warping • Optical clarity provides distortion-free microscopy • Vented lids improve gas exchange • Sta…
A Sensitive solution for HPLC, fast-LC and CE systems High Sensitivity: 10 times to 100 times greater than conventional fluorescence and up to 100,000 times more sensitive than UV detection. Versatility: 14 interchangelable different lasers availables for any application Modularity : Adaptable to CE and HPLC systems including Fast-LC, Capillary LC and nanoLC.Selectivity: Low noise and interference molecules will be detected.…
GenePro Thermal Cycler is the latest generation of thermal cycler with multiple functions tailored by BIOER. With its powerful functions, Genepro guarantees reliable and stable experimental results. The characteristics of the product provide a wide range of choices, but also highlights the individuality of design: it can meet not only a variety of experimental requirements, such as gradient pcr, and touch down PCR, but also t…
InGenius3 is an economical gel documentation system. You can image your choice of dyes and stains by choosing UV, blue or white lighting options. The system’s GeneSys software selects the right lighting and filters for you, making it easy to image fluorescent ethidium bromide or SYBR® Safe DNA gels and protein gels stained with Coomassie Blue or silver.
These spectrophotometers provide superb performance, powerful ESEF software and are fully accessorised.
The DNA kits are ideal for automated sizing and quantitation of PCR fragments, restriction digests or fragmented DNA.
The Agilent RNA kits with the patented RNA Integrity Number (RIN) are the industry standard for RNA quality assessment. Do fast, easy and precise integrity checks and sample quantitation before any RNA dependent application. Maximum flexibility €“ check the quality of your total RNA, mRNA, or cRNA samples Minimal sample consumption €“ use as little as 5 ng of total RNA or 50 pg of total RNA for analysis, savi…
The second generation of our QuikChange method that provides improved fidelity over our original kit, while maintaining greater than 80% mutation efficiency for single site mutagenesis.
Spare parts and accessories available for the Agilent 2100 Bioanalyzer.
The engineered PfuUltra II Fusion HS DNA Polymerase provides the worlds most accurate copies and the fastest extension times possible. PfuUltra II Fusion HS DNA Polymerase is PfuUltra hotstart DNA polymerase coupled with a fusion polymerase technology and ArchaeMaxx PCR enhancing factor. The industry standard for ultra high fidelity PCR providing the most accurate copies of DNA Dramatically reduced extension times allow f…
Brilliant II QRT-PCR reagents were developed to maintain the high quality of our original Brilliant product line, but with a significant improvement in sensitivity of detection, ensuring reproducible quantification even at low target concentrations. With the addition of ROX reference dye to our master mix, we have streamlined the reaction setup process.
Brilliant II SYBR qPCR and QRT-PCR reagents provide improved sensitivity and detection while ensuring reproducible quantification at low target concentrations. Compared to other commercially available qPCR reagents, Brilliant II SYBR qPCR and QRT-PCR reagents have earlier threshold cycle (Ct) detection at high and low template concentrations.
Brilliant II QPCR reagents were developed for improved sensitivity of detection, ensuring reproducible quantification even at low target concentrations. For faster experiments with earlier Ct's and greater reproducibility, Agilent recommends Brilliant III Ultra-Fast master mixes.
These reactions buffers contain the optimal magnesium concentration for efficient PCR. Ideal for optimal PCR performance Standard 10x formulation Optimized for use with specific PCR enzymes
The Classic Series gel tanks come with turn and cast gel trays or gasketed gel trays, making gel pouring as simple as possible. Designed to give you total felxibility in your application. Avaialble in a variety of sizes: From the small 7 x 8cm gel size right up to the 20 x 40cm gel size for high-throughput applications. Product Detail: Turn and Cast Submarine Gel System Three convenient gel sizes: 7x8cm; 9x11cm & 12x14c…
Agilent™s Model Organism ChIP-on-chip Microarrays provides researchers with clear insight into species research through traditional chromatin immunoprecipitation (ChIP) pull-down coupled with powerful DNA microarray location analysis. Beyond embryonic and adult development gene regulation, Agilent™s ChIP-on-chip model systems effectively elucidates the vital biological processes. Probe number depends on species 4x44k and…