Flow Cytometry / Cell Counting Products & Reviews

25

Flow cytometers are used to count, sort and examine multiple characteristics of cells. Other cell analysis equipment includes image cytometers, cell counters, fluorescence-activated cell sorters (FACS), magnetic-activated cell sorters (MACS), and a range of flow cytometry assay kits. Flow cytometers can reveal information on cell viability, cell proliferation, apoptosis and cell cycle progression, as well as identify cell populations and intracellular or cell-surface molecules. Additionally, some flow cytometers, known as FACS, have an additional sorting function after analysis. Cell counters and image cytometers count live and dead cell populations and can also conduct cell proliferation assays. Find the best flow cytometers, cell counters and cell sorters in our peer-reviewed product directory: compare products, check customer reviews and receive pricing direct from manufacturers.

Product Filter

Explore by Field
Flow Cytometry / Cell Counting
Refine your selection
Explore by Company

Ratings

Search

Selected Filters:

CyStain UV OxProtect

Sysmex Europe SE

Ready-to-use reagent for the extraction and staining of nuclei in one step. DAPI as a dye enables the determination of genome size variations and ploidy level in material or cell suspensions of various origins, including mammalian cells and plant material. CyStain UV OxProtect is especially formulated to prevent oxidation and degradation processes triggered by endogenous plant tissue oxidants.

0.0/5.0
|0 Reviews
Request Pricing



Exosome Isolation

AMSBIO

AMSBIO has developed and optimized methods and tools for fast, scalable and reproducible Extracellular Vesicle (EV) purification, as well as addressing EV heterogeneity and high throughput solutions for biomarker discovery.

0.0/5.0
|0 Reviews


ToxCount™

Active Motif

ToxCount™ provides a two wavelength cell viability assay based on determination of live and dead cells. The assay uses fluorescent dyes that measure permeability of the plasma membrane of dying cells and the ability of living cells to retain intracellular esterases, respectively. Live cells are distinguished by the presence of ubiquitous intracellular esterase activity, determined by the enzymatic conversion of the non fluores…

0.0/5.0
|0 Reviews

Human Multipotent Mesenchymal Stromal Cell Multi-Color Flow Cytometry Kit

Bio-Techne

Product Description This kit contains four conjugated antibodies (and corresponding isotype controls) that can be used for single-step staining of human multipotent mesenchymal stromal cells (hMSCs) (1 - 4): Positive Markers • CD105-PerCP (Clone 166707; mouse IgG1) • CD146-CFS (Clone 128018; mouse IgG1) • CD90-APC (Clone Thy-1A1; mouse IgG2A) Negative Marker • CD45-PE (Clone 2D1; mouse IgG1) This kit also contains Staining Buf…

0.0/5.0
|0 Reviews

Cell Organelle Toolbox

Chromotek GmbH

Being able to visualize endogenous cellular structures in live cells is key for many high content analyses. The two Chromobodies® of the ChromoTek’s Cell Organelle Toolbox offer a new way to investigate key compartments of the cell non-invasively. Lamin-Chromobody® The new Lamin-Chromobody® is a major breakthrough especially in High-Content Analysis (HCA) as apoptosis assays thus far rely on static endpoint assays. The nucle…

0.0/5.0
|0 Reviews

FlowCellect™ Human NK Cell Characterization Kit

Merck

The FlowCellect™ Human NK Cell Characterization Kit includes three directly conjugated antibodies, Anti-CD3-APC, Anti-CD56-PE, and Anti-CD16 FITC. This three color kit is designed to characterize NK within mixed cell populations. The antibodies provided have been carefully titrated to ensure the ability to accurately measure the expression of all markers simultaneously. Sufficient reagents are provided to perform 25 three-colo…

0.0/5.0
|0 Reviews

FlowCellect™ Cell Cycle Checkpoint H2A.X DNA Damage Kit

Merck

Millipore’s FlowCellect™ DNA Damage (Histone H2A.X) and Cell Cycle Analysis Kit is designed to identify the linkage between DNA damage in relation to cell cycle checkpoints in flow cytometry applications. The kit includes a directly conjugated Anti-phospho-Histone H2A.X (Ser139) Alexa Fluor® 488 antibody plus a DNA dye (Propidium Iodide) which allows the researcher to perform bivariate analysis to identify where DNA damage ta…

0.0/5.0
|0 Reviews

FlowCellect™ Cell Cycle Checkpoint ATM DNA Damage Kit

Merck

Millipore’s FlowCellect™ DNA Damage (ATM) and Cell Cycle Analysis Kit is designed to identify the linkage between DNA damage in relation to cell cycle checkpoints in flow cytometry applications. The kit includes a directly conjugated Anti-phospho-ATM (Ser1981) Alexa Fluor® 488 conjugate plus a DNA dye (Propidium Iodide) which allows the researcher to perform bivariate analysis to identify where DNA damage takes place relativ…

0.0/5.0
|0 Reviews

FlowCellect™ Bivariate Cell Cycle Kit for DNA Replication Analysis

Merck

Millipore’s FlowCellect™ Bivariate Cell Cycle Kit for DNA Replication Analysis is designed to investigate cells undergoing replication in S-phase of the cell cycle with high accuracy and confidence in flow cytometry applications. The kit includes a directly conjugated Anti-BrdU Alexa Fluor® 488 conjugate plus a DNA dye (Propidium Iodide) which allows the researcher to perform bivariate analysis to distinguish cells in two dim…

0.0/5.0
|0 Reviews

FlowCellect™ Bivariate Cell Cycle Kit for G2/M Analysis

Merck

Millipore’s FlowCellect™ Bivariate Cell Cycle Kit for G2/M Analysis is designed to allow the researcher to easily identify, discriminate, and quantitate cells between the G2 and M-phases of the cell cycle. The kit can be used to perform bivariate analysis to measure cell cycle distributions by discrimination of cell cycle phases without the need of sophisticated software modules or algorithms. Having the ability to distingui…

0.0/5.0
|0 Reviews

FlowCellect™ Multi-Color DNA Damage Response Kit

Merck

Millipore’s FlowCellect™ Multi-Color DNA Damage Response Kit is designed to enable a researcher a quick and easy way to detect the phosphorylation state of ATM, SMC1 and Histone H2A.X by flow cytometry. Millipore’s FlowCellect™ Multi-Color DNA Damage Response Kit was developed and tested using the DNA damaging reagent, Etoposide, in HeLa cells as a model system but the kit can be used with other human cell lines to determine…

0.0/5.0
|0 Reviews




Cellena®

Biomedal

Cellena® is a bioencapsulation portable platform able to encapsulate high molecular weight compounds, microorganisms and cells in homogeneus particles of predictable and controlable size. Designed by Ingeniatrics, it has been specifically developed for biotechnological research. Its performance is based on Flow Focusing® technology. By means of this technology, the elements to be encapsulated are immobilized within a semiperme…

0.0/5.0
|0 Reviews


GreenLight® 930

MOCON

Same-day microbial analysis for process control and product testing. The GreenLight Model 930 is ideal for companies looking for the benefit of same-day results when processing large numbers of samples for aerobic bacteria counts. Its advanced measurement technology, combined with labor and consumable savings, speed to result, high throughput, and flexibility makes agar plate and film testing obsolete. Benefits: Massive…

0.0/5.0
|0 Reviews

FAM FLICA® Caspase 1 Assay Kit

Immunochemistry Technologies LLC

Detect caspase-1 activity with the FLICA® Caspase 1 Assay Kit. This in vitro assay employs the green fluorescent inhibitor probe FAM-YVAD-FMK to label active caspase 1 enzyme in living cells or tissue samples. Analyze the fluorescent signal using fluorescence microscopy, a fluorescent plate reader, or by flow cytometry. Caspase 1 (ICE):Members of the mammalian caspase family of cysteinyl aspartate-specific proteases play disti…

0.0/5.0
|0 Reviews

Flow Cytometer Calibration Beads

Takara Bio

Flow Cytometer Calibration Beads for AcGFP/EGFP and mCherry. Use these beads to calibrate your flow cytometer prior to analyzing cells that express the AcGFP1 or mCherry fluorescent proteins. The AcGFP Flow Cytometer Calibration Beads allow for easy calibration of any flow cytometer with a 488 nm laser line that excites the green fluorescent proteins AcGFP1 (Aequorea coerulescens GFP) and EGFP. [The AcGFP Flow Cytometer Calib…

0.0/5.0
|0 Reviews

Chromogenic ID

Synbiosis

Chromogenic ID – colour recognition module to make the analysis of chromogenic agars accurate and simple to interpret. Chromogenic ID is a new generation colour recognition module designed to make the analysis of chromogenic agars accurate and simple to interpret. Chromogenic ID, designed to work with various commercial brands, fits seamlessly alongside the ProtoCOL 3 colony counting and zone measuring software. Organisms are…

0.0/5.0
|0 Reviews