Anti-Mouse IgG Fc (MFC) Probes
Gator BioBinds mouse IgGs and mouse Fc-fusion proteins. Recommended for rapid screening for quantitation, off-rate ranking for antibodies, kinetic screening and epitope binning.
Biosensor Systems, Automated
Binds mouse IgGs and mouse Fc-fusion proteins. Recommended for rapid screening for quantitation, off-rate ranking for antibodies, kinetic screening and epitope binning.
Small Molecule, Antibody, and Protein biosensor
Binds biotinylated or AviTag containing biomolecules. For use in kinetic measurements or in creating custom-made biosensors.
Binds human IgGs and human Fc-fusion proteins. Recommended for rapid screening for quantitation, off-rate ranking for antibodies, kinetic screening, and epitope binning.
Binds IgGs of various species, including human and mouse. Dynamic range of 0.02 – 2000 µg/mL. Can be robustly regenerated.
Binds IgGs of various species, including human and rat. Dynamic range of 0.02 – 2000 µg/mL. Can be robustly regenerated.
Binds IgGs of various species through the kappa light chain. Dynamic range of 0.02 – 2000 µg/mL.
Binds His-tagged proteins. Can be used for rapid quantitation, kinetic measurements and epitope binning. Can be regenerated.
Covalently bonded to amine groups on proteins. Recommended for use in kinetics measurements and indirect quantitation experiments. This biosensor uses EDC/NHS activation and coupling to link proteins.
Used to bind hydrophobic proteins or to create custom-made biosensors.
The Gator ® Ni-NTA probes enabler rapid and continuous quantification of His-tagged proteins without the need for Ni2+ recharging. The stable immobilization of His-tagged proteins allows for facile kinetics analysis with binding partners, off-rate screening, and epitope binning of antibodies experiments.
Gator Bio offers many on-demand probes such as Anti-RBD SARS-COV-2; Anti-Rabbit; Anti-Rat; Anti-Flag
The Gator ® AAV9 Probes are high specificity nanobody-based biosensors that enable direct capture and quantitation of AAV9 in crude lysates, column eluates, cell lysates and cell culture supernatants. The Gator ® AAV9 probe uses proven CaptureSelect™ (Thermo Fisher Scientific) high affinity and high specificity anti-AAV9 nanobody.
HFCII probes are high-performance nanobody-based biosensors that can detect and quantitate human IgG and its isotypes in different buffers (Q, K), cell culture supernatant, cell media, and other crude samples. Dynamic range: 0.3-6000 µg/mL in Q buffer; 1-2000 µg/mL (in diluted cell culture media).
The Gator ® High Sensitivity (HS) AAV9 Kit enable high sensitivity quantification of AAV9 in crude and purified samples. The HS AAV9 Kit includes: HS AAV9 probes (96 probes/tray) HS AAV9 Detection Solution AAV Amplification Solution AAV Substrate Solution AAV Substrate Diluent Q Buffer ** Contains temperature sensitive components. Must be shipped overnight. ** *Not compatible with Gator ® AAV9 probe (Part No. 160021)
Streptavidin probes for kinetic analysis of a wide range of biomolecules such as peptides, proteins, and large lipid nanoparticles.
Extending walk-away time while delivering fast, reproducible and high-quality data The Gator ® Pro instrument is designed for fast, automated, high-throughput analysis. 32 spectrometers enable high frequency parallel measurement of up to 32 samples. 3 sample plates enable automated data acquisition of 1152 samples per batch.
Octet® FAB2G biosensors come pre-immobilized with a high-affinity ligand that is specific for the CH1 region of Human IgG. The anti-human CH1 ligand has no recognition towards free light chains or cross-reactivity with murine or bovine IgG. This high level of specificity enables direct analysis of IgG or Fab analytes directly from complex samples such as cell culture supernatants, lysates, or partially purified samples, offer…
Octet® AHQ biosensors provide a rapid method for precise quantitation of human immunoglobulins from crude lysates and cell culture supernatants. Factory immobilization of an anti-human IgG antibody onto the biosensor surface enables direct detection of human IgG analytes with minimal sample handling and facilitates sample quantitation from cell culture screening through downstream purification development.
Octet® ProA biosensors are coated with Protein A and enable rapid antibody quantitation from crude lysates, cell culture supernatants and complex matrices.
Octet® AMQ biosensors provide a rapid method for precise quantitation of murine immunoglobulins from crude lysates and cell culture supernatants.
Octet® APS Biosensors are coated with aminopropylsilane and provide a convenient method for hydrophobic based immobilization of most protein analytes for assaying the kinetic profile of protein-protein interactions.
Octet® SSA (Super Streptavidin) Biosensors offer the highest sensitivity for the demands of small molecule kinetic experiments.
Octet® Anti-Human Fc Capture (AHC) Biosensors are designed for kinetic characterization of interactions between human Fc-containing proteins and target analytes. Octet® AHC Biosensors are offered in a tray format. Each tray contains 96 biosensors. Larger orders include discounts.
Octet® Anti-Mouse Fc Capture (AMC) Biosensors are designed for kinetic characterization of interactions between mouse Fc-containing proteins and target analytes. Octet® AMC Biosensors are offered in a tray format. Each tray contains 96 biosensors.