Greenhouse Gases Analyzers
Agilent TechnologiesMonitor greenhouse gas emissions with analyzers preconfigured to adhere to regulatory (EPA, EN) standards.
Monitor greenhouse gas emissions with analyzers preconfigured to adhere to regulatory (EPA, EN) standards.
The Agilent LTM (Low Thermal Mass) Series II gives fast results on large numbers of samples, which is critical for laboratories that require fast turnaround time and high sample throughput, such as petrochemical, food testing, and pharmaceutical QC labs.
Based on the 7010B Triple Quadrupole GC/MS, Agilent’s Pesticides and Environmental Pollutants GC/MS/MS Analyzer 4.0 with the MassHunter Pesticide & Pollutant MRM Database provides the lowest possible detection and quantitation limits for pesticides residues in complex matrices.
OpenLab CDS EZChrom provides superior control of Agilent LC and GC instruments, plus the most complete control of other vendors’ instruments.
Polar-modified column; available in 3.0, 4.0, 4.6, 10, 21.2 and 50 mm id; 30 - 250 mm length. From the collapse-resistant pore structure of the base silica, to the "wettability" engineered into the bonded phases, Polaris columns have been designed for high aqueous conditions. The combination of high-phase density bonding, ultra pure silica and silanol shielding leads to excellent peak shape among polar-modified columns.
ZORBAX 80Å StableBond columns are made using bulky, patented, unique silanes that sterically protect the siloxane bond. Acid labile endcapping reagents are not used. The result is vastly improved column life and extraordinary chemical and temperature stability in the pH 1–6 range for a wide variety of phases (SB-Aq, SB-C3, SB-CN, SB-Phenyl, SB-C8, and SB-C18). Excellent peak shape is expected for many basic compounds because…
Bonus-RP columns provide unique selectivity and applicability for mid pHs with an embedded amide linkage in the C14-alkyl chain. At pH 7 Bonus-RP provides excellent peak shape for even the most challenging basic compounds.
The 1290 Infinity II Refractive Index Detector (RID) is a UHPLC RID detector that provides excellent sensitivity, resolution, and sample throughput for UHPLC DRI experiments. The 1290 Infinity II RID is a equipped with an ultralow dispersion microflow cell and a data rate of 148 Hz, which significantly reduces run times for higher sample throughput and improved resolution and sensitivity.
The 1260 Infinity II Bio-Inert LC is a dedicated solution for analysis of large biomolecules in biological samples, including monoclonal antibody (mAb) and protein analysis. Metal-free components in the sample flow path and the absence of iron and steel in solvent delivery lines ensure the integrity of your biomolecules, minimize unwanted surface interactions, and increase column lifetime.
The 1260 Infinity II Degasser is suitable for analytical applications with flow rates up to 10 mL/min and up to four solvents. It is highly recommended for GPC/SEC applications using refractive index detection. It reduces baseline noise and quenching effects due to high degassing capacity.
The 1290 Infinity Flexible Cube is an auxiliary module that allows flexible online SPE applications by supporting up to two Agilent Quick Change Valve drives for online SPE valves and a built-in pump to facilitate enhanced flushing capabilities and to reduce carryover.
Qualified reagents for the polyadenylation of microRNAs (miRNAs) from total RNA and synthesis of first-strand cDNA from the tailed miRNAs.
The Mx3005P system is among the most reliable and trusted QPCR instruments available, with a long record of citation in peer-review journals. The Agilent Mx3005P and Mx3000P QPCR Systems are the most flexible—and reliable—instruments available for gene expression analysis, microarray data validation, SNP genotyping, pathogen detection, DNA methylation analysis, and chromatin immuno-precipitation studies.Highly reproducible re…
Bond Elut C18 is the most hydrophobic, bonded silica sorbent available in the Bond Elut range. It is the most popular SPE sorbent because of its extreme retentive nature for nonpolar compounds. C18 is generally regarded as having the broadest spectrum of retention among bonded silica sorbents, since it retains most organic analytes from aqueous matrices.
A variety of empty reservoirs is available to increase the sample capacity of Bond Elut extraction cartridges. These tubes can also be used to pack custom SPE cartridges with bulk Bondesil sorbents or other desired sorbent. They are available from 1 to 60 mL.
Bond Elut PSA is an alkylated amine sorbent that contains two different amino functionalities, one secondary and one primary. This gives a slightly higher pKa and ionic capacity compared to Bond Elut NH2. PSA has a significantly higher carbon load than most amino functional sorbents and thus is a better choice for polar compounds, which retain too strongly on Bond Elut NH2.
Agilent split liners are made to strict dimension specifications for optimal inlet performance and feature the tightest tolerances for od, id, taper and glass wool placement.
LC Manual Syringes with PTFE-Tipped Plungers
Prevent unknown peaks from impacting your results Agilent MS Analyzed Vial Kits end the need to pre-test or to rerun samples due to unexpected peaks. Eliminating vials as a source of contamination translates into confidence that your results are accurate and reliable. All MS Analyzed Vials Kits include a Certificate of Analysis that contains true lot-specific and fully traceable LC/MS and GC/MS signal traces as well as criti…
The Cary 5000 is a high-performance UV-Vis and NIR spectrophotometer with superb photometric performance in the 175–3300 nm range. Using a PbSmart detector, the Cary 5000 extends its NIR range to 3300 nm making it a powerful tool for materials science research. The Cary WinUV software, a modular Windows-based software, makes it easy to perform powerful analysis and control a number of optional accessories.
The Cary 4000 is a high-end UV-Vis spectrometer with excellent photometric performance in the 175–900 nm range, making it a powerful reference spectrometer. The system is ideal for analyzing solid samples or biotechnology samples with minimal sample preparation.
The ZORBAX Eclipse AAA high efficiency HPLC column rapidly separates amino acids following an updated and improved protocol. Total analysis from injection to injection can be achieved in as little as 14 min (10 min analysis time) on the short, 7.5 cm column and 24 min (16 min analysis time) on the 15 cm column length.Exceptional sensitivity (5 - 50 pmol with DAD, FLD) and reliability are achieved using both OPA and FMOC deriv…
The engineered PfuUltra II Fusion HS DNA Polymerase provides the worlds most accurate copies and the fastest extension times possible. PfuUltra II Fusion HS DNA Polymerase is PfuUltra hotstart DNA polymerase coupled with a fusion polymerase technology and ArchaeMaxx PCR enhancing factor. The industry standard for ultra high fidelity PCR providing the most accurate copies of DNA Dramatically reduced extension times allow f…
Brilliant II QRT-PCR reagents were developed to maintain the high quality of our original Brilliant product line, but with a significant improvement in sensitivity of detection, ensuring reproducible quantification even at low target concentrations. With the addition of ROX reference dye to our master mix, we have streamlined the reaction setup process.