Strata-X-Drug Solid Phase Extraction

Phenomenex Inc

Strata-X Drug B and N Solid Phase Extraction (SPE) sorbents are designed and quality control tested for basic and neutral drugs of abuse analysis, respectively. The sorbents are QC tested using drug probes from urine samples so that you can have confidence in your results. The sorbents also do not require conditioning/equilibrating steps, saving both time and solvent.

4.6/5.0
|4 Reviews




Multi-Gen 7XL Homogenizer Package

PRO Scientific, Inc.

Multiple sample homogenizing can be time consuming and can create concerns of cross-contamination. PRO Multi-Sample Homogenizer Kit provides the most effective method for homogenizing multiple samples at a time within 1.5ml - 50ml tubes as well as it can eliminate cross-contamination concerns.

4.7/5.0
|9 Reviews



ProLine Mass Spectrometer

Ametek, Inc.

A compact benchtop process mass spectrometer for general purpose locations. With a choice of 8 or 16 sample inlet ports, the ProLine can be configured for any application. Interchangeable quadrupole head and electronics with automatic tuning eliminate the need for specialist service technicians.

5.0/5.0
|3 Reviews

Finnigan™ LTQ™

Thermo Fisher Scientific

The Finnigan LTQ high-performance 2-Dimensional Ion Trap Animations mass spectrometer redefines performance for metabolic and proteomics analyses. Product detail: Finnigan LTQ LC/MSn The Finnigan LTQ linear ion trap mass spectrometer represents a leap in LC/MSn ion trap performance. Combining patented technology from the field-proven LCQ series with advanced designs in linear trap, ion source, optics, and detector techno…

4.8/5.0
|4 Reviews

Agilent Pursuit C18 (USP L1) HPLC Columns

Agilent Technologies

200A pore size;  available in 2.0, 3.0, 3.9, 4.0, 4.6, 10 , 21.2 and 50  mm ids, and lengths from 50 - 250 mm. Pursuit columns are ideal for pharmaceutical applications using LC/MS, from analyzing lead compounds and biological samples in drug discovery, to implementing dependable analysis of raw materials and approved drugs in the QC process.  Build on the large 200A pore size silica, high liquid density delivers up to 40% fas…


Residual Gas Analyzer

Stanford Research Systems Inc.

Residual Gas Analyzer - RGA100, RGA200 and RGA300 100, 200 and 300 amu systems Better than 1 amu resolution 6 orders of magnitude dynamic range in a single scan 5 x 10-14 Torr detection limit RGA Windows and LabVIEW software Field-replaceable electron multiplier and filament RS-232 (std.) and Ethernet (opt.) interfaces Features and benefits The 100, 200 and 300 amu residual gas analyzers from SRS offer excepti…

4.7/5.0
|1 Review

Agilent Select FAME GC Columns

Agilent Technologies

The Select FAME column is tuned for optimal cis/trans separations of FAMEs, especially the C18 isomers. The bonded column has an isothermal maximum operation temperature of 275°C and a programmed temperature of 290°C - a dramatic improvement of 50°C compared to non-bonded columns. Select FAME has better detection limits because the column has a very low bleed level. Even though this is a very polar column, the column efficienc…

4.5/5.0
|2 Reviews


HP-5ms GC Columns

Agilent Technologies

Agilent J&W HP-5ms has very low bleed characteristics that are ideal for GC/MS. The column has excellent inertness for active compounds, including acidic and basic compounds, and improved signal-to-noise ratio for better sensitivity and mass spectral integrity.

5.0/5.0
|2 Reviews

HP-FFAP Columns

Agilent Technologies

Agilent J&W HP-FFAP is designed primarily for the analysis of organic acids, free fatty acids, or samples that require quantitation of acidic impurities. The FFAP stationary phase is modified with acid to provide a very inert column that can accommodate the demanding analysis of acids dissolved in water. 

5.0/5.0
|1 Review

CP-Wax 52 CB columns

Agilent Technologies

CP-Wax 52 CB GC columns have lower minimum temperature and a higher maximum temperature than non-bonded polyethylene glycol (PEG) columns due to extensive cross linking, delivering higher resolution of low-boiling-point analytes. With guaranteed reproducibility and excellent temperature stability, CP-Wax 52 CB is ideal for EPA and ASTM methods.

5.0/5.0
|1 Review

CP-Sil 88 Columns for Dioxins

Agilent Technologies

Agilent J&W CP-Sil 88 for Dioxins has a very high polarity and a specific selectivity for dioxin and dibenzofuran separations. The column is supplied with an integrated retention gap to avoid problems with solvent condensation, thus allowing repeated splitless injections without phase deterioration, extending column life. 

5.0/5.0
|1 Review

DB-624 GC Columns

Agilent Technologies

Agilent J&W DB-624 is recommended for EPA methods 502.2 and 8021, as well as for fast GC/MS volatiles analysis. It is specifically designed for the analysis of volatile priority pollutants and residual solvents.

4.9/5.0
|2 Reviews

7697A Headspace Sampler

Agilent Technologies

Introduce volatile compounds from virtually any sample matrix into your GC or GC/MS. Automatic Leak Check, Priority Sample Positions, and Barometric Pressure Compensation improve uptime and efficiency.

4.7/5.0
|5 Reviews

Capillary Flow Technology

Agilent Technologies

Dependable leak-free capillary connections allow reliable backflush, split flow, heart-cutting, and GC x GC on Agilent 8890 and 7890 GC systems. These devices are low thermal mass, oven mountable, and inert.

5.0/5.0
|1 Review

GC/MS Forensic Toxicology Analyzer 

Agilent Technologies

GC/MS methods are widely used for forensic toxicology, especially for the screening of large numbers of target compounds in complex matrices. Full-scan EI methods offer many advantages for broad-range screening, such as an unlimited number of targets, full-spectrum identity confirmation, and library searching for identification of non-targets. Technologies such as Capillary Flow Technology backflushing, Deconvolution Reporting…

4.5/5.0
|4 Reviews


Purge and Trap

Agilent Technologies

Purge and Trap (P&T) performs highly sensitive volatile organic compound (VOC) analysis with low carryover, allowing accurate and precise GC and GC/MS determination of VOCs in water, wastewater, soils, and sludges.

5.0/5.0
|1 Review

GC/MS PAH Analyzer

Agilent Technologies

Based on the 7890 GC and 5977A Series Single Quadrupole Mass Spectrometer, the GC/MS PAH Analyzer is suitable for analyzing poly-cyclic aromatic hydrocarbons in environmental and food samples. 

5.0/5.0